The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
A Simple and Sensitive “Dipstick” Test in Serum Based on Lateral Flow Separation of Aptamer‐Linked Nanostructures
Abstract
A quick plunge: By using lateral flow devices as a platform to separate aptamer-assembled nanoparticle (NP) aggregates, highly sensitive and selective colorimetric sensors were constructed that mimic litmus paper tests. Detection of cocaine in serum was also realized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
A DNA Aptamer That Binds Adenosine and ATP
Huizenga, D. E., & Szostak, J. W. (1995) · Biochemistry · doi:10.1021/bi00002a033 · Cited by 1,270
In Vitro Selection of Functional Nucleic Acids
Wilson, D. S., & Szostak, J. W. (1999) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.68.1.611 · Cited by 1,206
Liu, J., & Lu, Y. (2006) · Nature Protocols · doi:10.1038/nprot.2006.38 · Cited by 1,126
Self-citationStructure-Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028962o · Cited by 1,040
Liu, J., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502589 · Cited by 956
Self-citation
Cited by
Applications of Nanoparticles in Biology
De, M., Ghosh, P. S., & Rotello, V. M. (2008) · Advanced Materials · doi:10.1002/adma.200703183 · Cited by 1,547
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Nanotechnology, nanotoxicology, and neuroscience
Suh, W. H., Suslick, K. S., Stucky, G. D., & Suh, Y.-H. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.09.009 · Cited by 406
Nanoparticles for detection and diagnosis
Agasti, S. S., Rana, S., Park, M.-H., Kim, C. K., You, C.-C., & Rotello, V. M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.004 · Cited by 313
On-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86
Metadata
- Authors
- Liu, J., Mazumdar, D., & Lu, Y.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2006-11-27
- Volume
- 45
- Issue
- 47
- Pages
- 7955-7959
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2167875539
- Cited by
- 346
- References
- 22
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Simple and Sensitive “Dipstick” Test in Serum Based on Lateral Flow Separation of Aptamer‐Linked Nanostructures. https://app.cochat.ai/papers/10.1002/anie.200603106
- The paper
- Liu, J., Mazumdar, D., & Lu, Y. (2006). A Simple and Sensitive “Dipstick” Test in Serum Based on Lateral Flow Separation of Aptamer‐Linked Nanostructures. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200603106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.