Using the Hough Transform to Segment Ultrasound Images of Longitudinal and Transverse Sections of the Carotid Artery
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004 · cited 1×
“To identify the boundaries of the arterial wall layers, edge detection using the Canny method (Canny 1986), a multistep robust method, was used.”
MethodBeneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Use of the hough transformation to detect lines and curves in pictures
Duda, R. O., & Hart, P. E. (1972) · Communications of the ACM · doi:10.1145/361237.361242 · Cited by 6,633
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Generalizing the Hough transform to detect arbitrary shapes
Ballard, D. H. (1981) · Pattern Recognition · doi:10.1016/0031-3203(81)90009-1 · Cited by 4,371
Warlow, C. (1991) · The Lancet · doi:10.1016/0140-6736(91)92916-p · Cited by 3,237
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Buchan, A. M. (1991) · New England Journal of Medicine · Cited by 947
The Causes and Risk of Stroke in Patients with Asymptomatic Internal-Carotid-Artery Stenosis
Inzitari, D., Eliasziw, M., Gates, P., Sharpe, B. L., Chan, R. K. T., Meldrum, H. E., & Barnett, H. J. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200006083422302 · Cited by 876
Finding circles by an array of accumulators
Kimme‐Smith, C., Ballard, D. H., & Sklansky, J. (1975) · Communications of the ACM · doi:10.1145/360666.360677 · Cited by 664 · cited 1×
“, line detection (Duda and Hart 1972), circle detection (Kimme et al. 1978), arbitrary shape extraction (Ballard 1981) and motion extraction (Nash et al.”
MethodWendelhag, I., Gustavsson, T., Suurküla, M., Berglund, G., & Wikstrand, J. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00676.x · Cited by 515
Salonen, R., & Salonen, J. T. (1990) · Atherosclerosis · doi:10.1016/0021-9150(90)90056-o · Cited by 445
Wendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J. (1997) · Stroke · doi:10.1161/01.str.28.11.2195 · Cited by 375
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323 · cited 1×
“Alternative despeckling techniques (Loizou et al. 2005) may also be applied.”
Texture-based classification of atherosclerotic carotid plaques
Christodoulou, C. I., Pattichis, C. S., Pantziaris, M., & Nicolaides, A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815066 · Cited by 316
A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform
Zana, F., & Klein, J. C. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774169 · Cited by 303
Diameter and compliance in the human common carotid artery — variations with age and sex
Hansen, F., Mangell, P., Sonesson, B., & Länne, T. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00090-5 · Cited by 293 · cited 1×
“The values for rmin and rmax were defined according to previously measured values of diastolic and systolic diameters, respectively, in healthy arteries (Hansen et al. 1995).”
MethodSelzer, R. (2001) · Atherosclerosis · doi:10.1016/s0021-9150(00)00461-5 · Cited by 275
Automatic Identification of the Pectoral Muscle in Mammograms
Ferrari, R. J., Rangayyan, R. M., Desautels, J. E. L., Borges, R. A., & Frere, A. F. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823062 · Cited by 213 · cited 2×
“For every candidate binary edge image pixel and for any angle min max, the coordinates (x, y) were calculated and the corresponding elements of the accumulator array were increased by the magnitude of the gradient, as suggested by Ferrari et al. (2004); thus, pixels with a strong gradient will have larger weights.”
MethodCheng, D.-C., Schmidt-Trucksäss, A., Cheng, K.-S., & Burkhardt, H. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00149-8 · Cited by 166
A real‐time biopsy needle segmentation technique using Hough Transform
Ding, M., & Fenster, A. (2003) · Medical Physics · doi:10.1118/1.1591192 · Cited by 115 · cited 1×
“2006) and real-time biopsy needle segmentation (Ding and Fenster 2003).”
Graf, S., Gariépy, J., Massonneau, M., Armentano, R. L., Mansour, S., Barra, J. G., Simon, A. C., & Levenson, J. A. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00089-7 · Cited by 110
Segmentation of carotid artery in ultrasound images: Method development and evaluation technique
Mao, F., Gill, J. D., Downey, D. B., & Fenster, A. (2000) · Medical Physics · doi:10.1118/1.1287111 · Cited by 108 · cited 1×
“Mao et al. (2000) reported average values of ai, an area-based metric corresponding to the sensitivity, equal to 0.”
BackgroundGill, J. D., Ladak, H. M., Steinman, D. A., & Fenster, A. (2000) · Medical Physics · doi:10.1118/1.599014 · Cited by 95
Tracking the left ventricle in echocardiographic images by learning heart dynamics
Malassiotis, S., & Strintzis, M. G. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.764905 · Cited by 91
Automated Segmentation of Lumbar Vertebrae in Digital Videofluoroscopic Images
Zheng, Y., Nixon, M. S., & Allen, R. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819927 · Cited by 80 · cited 1×
“Medical image applications of the HT include automated segmentation of lumbar vertebrae in videofluoroscopic images (Zheng et al. 2004), registration of eye fundus images (Zana and Klein 1999), automatic identification of the pectoral muscle in mammograms (Ferrari et al.”
MethodDynamic feature extraction via the velocity Hough transform
Nash, J. M., Carter, J. N., & Nixon, M. S. (1997) · Pattern Recognition Letters · doi:10.1016/s0167-8655(97)00128-1 · Cited by 65 · cited 2×
“1978), arbitrary shape extraction (Ballard 1981) and motion extraction (Nash et al. 1997).”
MethodWu, S.-Y., Shau, Y. ‐., Chong, F., & Hsieh, F. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345433 · Cited by 13 · cited 2×
“Although it has been suggested that the arterial wall in transverse sections can be approximated by ellipses (Wu et al. 2001), specificity and Table 1.”
BackgroundMethod
Cited by
Molinari, F., Zeng, G., & Suri, J. S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.04.007 · Cited by 222
“The circles represent the Hough transform detection of the lumen–intima interfaces in different cardiac cycle instants (Copyright© 2007 Elsevier, Reproduced from [79]).”
BackgroundMethod
Metadata
- Authors
- Golemati, S., Stoitsis, J., Sifakis, E. G., Balkizas, T., & Nikita, K. S.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2007-12
- Volume
- 33
- Issue
- 12
- Pages
- 1918-1932
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2010181125
- Cited by
- 188
- References
- 29
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.