CoChat

Echo Intensity Versus Muscle Function Correlations in Older Adults are Influenced by Subcutaneous Fat Thickness

Open access
Stock, Matt S., Whitson, Morgan, Burton, Adam M., Dawson, Nicole T., Sobolewski, Eric J., Thompson, Brennan J. · 2018 · Ultrasound in Medicine & Biology
Cited by 55

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Recently, an equation that allows investigators to correct echo intensity for subcutaneous fat was developed. We evaluated correlations between uncorrected and corrected echo intensity versus measures of lower-extremity function. Twenty-three older adults (11 men, 12 women; mean age = 72 y) participated. B-Mode ultrasonography was used to quantify rectus femoris echo intensity and subcutaneous fat thickness. Knee extensor isometric peak torque and rate of torque development at 200 ms (RTD200) were determined (joint angle = 90°). Fast gait speed was evaluated at 10- and 400-m distances. Partial correlations between normalized peak torque, RTD200 and 10- and 400-m gait speed versus uncorrected echo intensity were weak and insignificant. Correction for subcutaneous fat strengthened the correlations (peak torque r = -0.500, RTD200 r= -0.425, 10-m r = -0.409, 400-m r = -0.410). Correcting echo intensity values for subcutaneous fat strengthened the associations with lower-extremity muscle function in older adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2018.04.009

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 55

Metadata

Authors
Stock, M. S., Whitson, M., Burton, A. M., Dawson, N. T., Sobolewski, E. J., & Thompson, B. J.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2018-08
Volume
44
Issue
8
Pages
1597-1605
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2810834359
Cited by
55
References
8
FWCI
4.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Echo Intensity Versus Muscle Function Correlations in Older Adults are Influenced by Subcutaneous Fat Thickness. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2018.04.009
The paper
Stock, M. S., Whitson, M., Burton, A. M., Dawson, N. T., Sobolewski, E. J., & Thompson, B. J. (2018). Echo Intensity Versus Muscle Function Correlations in Older Adults are Influenced by Subcutaneous Fat Thickness. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2018.04.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.