The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Measuring contrast sensitivity
Open accessAbstract
Contrast sensitivity defines the threshold between the visible and invisible, which has obvious significance for basic and clinical vision science. Fechner's 1860 review reported that threshold contrast is 1% for a remarkably wide range of targets and conditions. While printed charts are still in use, computer testing is becoming more popular because it offers efficient adaptive measurement of threshold for a wide range of stimuli. Both basic and clinical studies usually want to know fundamental visual capability, regardless of the observer's subjective criterion. Criterion effects are minimized by the use of an objective task: multiple-alternative forced-choice detection or identification. Having many alternatives reduces the guessing rate, which makes each trial more informative, so fewer trials are needed. Finally, populations who may experience crowding or target confusion should be tested with one target at a time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1966) · Medical Entomology and Zoology · Cited by 10,293
Signal detection theory and psychophysics
Ingleby, J. D. (1967) · Journal of Sound and Vibration · doi:10.1016/0022-460x(67)90197-6 · Cited by 8,509
Application of fourier analysis to the visibility of gratings
Campbell, F. W., & Robson, J. G. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008574 · Cited by 3,019
Quest: A Bayesian adaptive psychometric method
Watson, A. B., & Pelli, D. G. (1983) · Perception & Psychophysics · doi:10.3758/bf03202828 · Cited by 2,410
Self-citationThe psychometric function: I. Fitting, sampling, and goodness of fit
Wichmann, F. A., & Hill, N. J. (2001) · Perception & Psychophysics · doi:10.3758/bf03194544 · Cited by 2,358
THE DESIGN OF A NEW LETTER CHART FOR MEASURING CONTRAST SENSITIVITY
Pelli, D. G., Robson, J. G., & Wilkins, A. J. (1988) · Cited by 1,308
Self-citationSEQUENTIAL ESTIMATION OF POINTS ON A PSYCHOMETRIC FUNCTION
Wetherill, G. B., & Levitt, H. (1965) · British Journal of Mathematical and Statistical Psychology · doi:10.1111/j.2044-8317.1965.tb00689.x · Cited by 1,196
PEST: Efficient Estimates on Probability Functions
Taylor, M. M., & Creelman, C. D. (1967) · The Journal of the Acoustical Society of America · doi:10.1121/1.1910407 · Cited by 1,173
Fechner, G. T. (1907) · doi:10.3931/e-rara-10879 · Cited by 1,021
Crowding—An essential bottleneck for object recognition: A mini-review
Levi, D. M. (2008) · Vision Research · doi:10.1016/j.visres.2007.12.009 · Cited by 976
The theory of signal detectability
Peterson, W., Birdsall, T., & Fox, W. (1954) · Transactions of the IRE Professional Group on Information Theory · doi:10.1109/tit.1954.1057460 · Cited by 867
Contrast sensitivity throughout adulthood
Owsley, C., Sekuler, R., & Siemsen, D. (1983) · Vision Research · doi:10.1016/0042-6989(83)90210-9 · Cited by 821
The psychometric function: II. Bootstrap-based confidence intervals and sampling
Wichmann, F. A., & Hill, N. J. (2001) · Perception & Psychophysics · doi:10.3758/bf03194545 · Cited by 810
Adaptive procedures in psychophysical research
Leek, M. R. (2001) · Perception & Psychophysics · doi:10.3758/bf03194543 · Cited by 808
Temporal and spatial summation in human vision at different background intensities
Barlow, H. B. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp005978 · Cited by 686
Bayesian adaptive estimation of psychometric slope and threshold
Kontsevich, L. L., & Tyler, C. W. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00285-5 · Cited by 668
The uncrowded window of object recognition
Pelli, D. G., & Tillman, K. A. (2008) · Nature Neuroscience · doi:10.1038/nn.2187 · Cited by 659
Self-citationAdaptive psychophysical procedures
Treutwein, B. (1995) · Vision Research · doi:10.1016/0042-6989(95)00016-s · Cited by 648
Churchill-Davidson, I., Sanger, C., & Thomlinson, R. H. (1957) · The British Journal of Radiology · doi:10.1259/0007-1285-30-356-406 · Cited by 609
Optical and Photoelectric Analog of the Eye
Schade, O. H. (1956) · Journal of the Optical Society of America · doi:10.1364/josa.46.000721 · Cited by 510
Feature detection and letter identification
Pelli, D. G., Burns, C. W., Farell, B., & Moore-Page, D. C. (2006) · Vision Research · doi:10.1016/j.visres.2006.04.023 · Cited by 454
Self-citationDe Valois, R. L., Morgan, H., & Snodderly, D. M. (1974) · Vision Research · doi:10.1016/0042-6989(74)90118-7 · Cited by 442
King-Smith, P. E., Grigsby, S. S., Vingrys, A. J., Benes, S. C., & Supowit, A. (1994) · Vision Research · doi:10.1016/0042-6989(94)90039-6 · Cited by 437
Origins of scaling in natural images
Ruderman, D. L. (1997) · Vision Research · doi:10.1016/s0042-6989(97)00008-4 · Cited by 355
Bayesian adaptive estimation of the contrast sensitivity function: The quick CSF method
Lesmes, L. A. (2010) · Journal of Vision · doi:10.1167/10.3.17 · Cited by 333
A standard model for foveal detection of spatial contrast
Watson, A. B., & Ahumada, A. J. (2005) · Journal of Vision · doi:10.1167/5.9.6 · Cited by 329
Sunness, J. S., Rubin, G. S., Applegate, C. A., Bressler, N. M., Marsh, M. J., Hawkins, B. S., & Haselwood, D. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30079-7 · Cited by 309
The remarkable inefficiency of word recognition
Pelli, D. G., Farell, B., & Moore, D. C. (2003) · Nature · doi:10.1038/nature01516 · Cited by 280
Self-citationHess, R. F., & Woo, G. C. (1978) · PubMed · Cited by 276
Pelli, D. G., & Farell, B. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.000647 · Cited by 275
Self-citationSpatial frequency, phase, and the contrast of natural images
Bex, P. J., & Makous, W. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.001096 · Cited by 270
Self-citationLi, J., Tripathi, R. C., & Tripathi, B. J. (2008) · Drug Safety · doi:10.2165/00002018-200831020-00003 · Cited by 226
Low-Contrast Letter Charts as a Test of Visual Function
Regan, D., & Neima, D. (1983) · Ophthalmology · doi:10.1016/s0161-6420(83)34407-9 · Cited by 210
APE: Adaptive probit estimation of psychometric functions
Watt, R. J., & Andrews, D. P. (1981) · Current Psychological Reviews · doi:10.1007/bf02979265 · Cited by 201
OWSLEY, C. (2003) · Ophthalmology Clinics of North America · doi:10.1016/s0896-1549(03)00003-8 · Cited by 195
Visual Acuity and Contrast Sensitivity in Patients with Cerebral Lesions
Bodis-Wollner, I. (1972) · Science · doi:10.1126/science.178.4062.769 · Cited by 194
Ocular Adverse Effects Associated with Systemic Medications: Recognition and Management
Santaella, R. M., & Fraunfelder, F. W. (2007) · Drugs · doi:10.2165/00003495-200767010-00006 · Cited by 187
Effect of Focus on the Visual Response to a Sinusoidally Modulated Spatial Stimulus*
Green, D. G., & Campbell, F. W. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001154 · Cited by 182
Hou, F., Huang, C., Lesmes, L., Feng, L., Tao, L., Zhou, Y., & Lu, Z. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5468 · Cited by 154
Contrast Sensitivity in Age-Related Macular Degeneration
Kleiner, R. C., Enger, C. L., Alexander, M. F., & Fine, S. (1988) · Archives of Ophthalmology · doi:10.1001/archopht.1988.01060130061028 · Cited by 149
Jäkel, F., & Wichmann, F. A. (2006) · Journal of Vision · doi:10.1167/6.11.13 · Cited by 147
Visual detection of spatial contrast patterns: Evaluation of five simple models
Watson, A. B. (2000) · Optics Express · doi:10.1364/oe.6.000012 · Cited by 138
Rapid and Reliable Assessment of the Contrast Sensitivity Function on an iPad
Dörr, M., Lesmes, L. A., Lu, Z., & Bex, P. J. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-11743 · Cited by 121
Self-citationLow Spatial-Contrast Sensitivity in Dry Eyes
Rolando, M., Iester, M., Macrì, A., & Calabria, G. A. (1998) · Cornea · doi:10.1097/00003226-199807000-00006 · Cited by 112
Studies of Psychophysical Methods for Measuring Visual Thresholds*†
Blackwell, H. R. (1952) · Journal of the Optical Society of America · doi:10.1364/josa.42.000606 · Cited by 112
Contrast sensitivity in humans with abnormal visual experience.
Freedman, R., & Thibos, L. N. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010952 · Cited by 97
Lesmes, L. A., Jeon, S.-T., Lu, Z., & Dosher, B. A. (2006) · Vision Research · doi:10.1016/j.visres.2006.04.022 · Cited by 89
A forced-choice test improves clinical contrast sensitivity testing.
Vaegan, & Halliday, B. L. (1982) · British Journal of Ophthalmology · doi:10.1136/bjo.66.8.477 · Cited by 86
The visual system in Parkinson's disease.
Bodis-Wollner, I. G., & ONOFRJ, M. C. (1987) · PubMed · Cited by 86
Test-types for the determination of the acuteness of vision
Snellen, H. A. (1862) · Utrecht University Repository (Utrecht University) · Cited by 47
Gandolfi, S., Cimino, L., Sangermani, C., Ungaro, N., Mora, P., & Tardini, M. G. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0199 · Cited by 40
Abnormal neurological signs, visual contrast sensitivity, and the deficit syndrome of schizophrenia
Cimmer, C., Szendi, I., Csifcsák, G., Szekeres, G., Kovács, Z. A., Somogyi, I., Benedek, G., Janka, Z., & Kéri, S. (2006) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2006.03.021 · Cited by 37
Suprathreshold Contrast Matching in Maculopathy
Mei, M., & Leat, S. J. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0731 · Cited by 27
(2016) · doi:10.1016/c2012-0-01278-1 · Cited by 21
Lu, Z., Wallis, J., Lu, Z., Jackson, M. L., & Bex, P. J. (2012) · Investigative Ophthalmology & Visual Science · Cited by 10
Self-citationDubois, M., Poeppel, D., & Pelli, D. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064803 · Cited by 10
Self-citationArt. XXIV.—Test-Types for the Determination of the Acuteness of Vision.
Snellen, H. A. (1863) · The American Journal of the Medical Sciences · doi:10.1097/00000441-186344920-00024 · Cited by 4
Cited by
Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
154, I. P. (2023) · Annals of the ICRP · doi:10.1177/01466453231210646 · Cited by 37
The effect of bangerter filters on visual acuity and contrast sensitivity with external noise
Zhang, P., Wang, H., Ren, W., Guo, H., Yang, J., Tao, J., Yang, Z., Li, Y., Chen, L., Zhang, Y., et al. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.804576 · Cited by 5
Metadata
- Authors
- Pelli, D. G., & Bex, P.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2013-09
- Volume
- 90
- Pages
- 10-14
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W1983976362
- Cited by
- 394
- References
- 57
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.