Role of telemetry monitoring in the non-intensive care unit
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
To determine the outcomes of patients admitted to a non-intensive care telemetry unit and to assess the role of telemetry for guiding patient management decisions, data from 2,240 patients admitted to a telemetry unit were collected prospectively during 7 months. Physicians recorded the outcomes (intensive care unit transfer and mortality) and assessed whether telemetry assisted in guiding patient management. Indications for admission to the telemetry unit included chest pain syndromes (55%), arrhythmias (14%), heart failure (12%), and syncope (10%). Telemetry led to direct modifications in management in 156 patients (7%; 95% confidence interval [CI] 5.9% to 8%). Telemetry was perceived as useful but did not alter management for 127 patients (5.7%; 95% CI 4.7% to 6.6%). Two hundred forty-one patients were transferred to an intensive care unit from the telemetry unit (10.8%; 95% CI 9.5% to 12%). Nineteen patients (0.8% of all admissions; 95% CI 0.5% to 1.2%) were transferred because of an arrhythmia identified by telemetry. Routine transfer after cardiac revascularization or surgery accounted for 134 transfers; clinical deterioration accounted for 88 transfers. There were 20 deaths in the unit (0.9%; 95% CI 0.5% to 1.3%): 4 of the 20 deaths occurred while patients were being monitored. The role of telemetry in guiding patient management may be overestimated by physicians, since it detected significant arrhythmias that led to change in medications or urgent interventions in a s…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Telemetry findings can be low yield and altered management in only 7% of cases in one study evaluating over 2,000 non-ICU patients (Estrada et al., 1995).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Estrada et al., 1995
Citations
Cites
Goldman, L., Cook, E. F., Brand, D. A., Lee, T. H., Rouan, G. W., Weisberg, M. C., Acampora, D., Stasiulewicz, C., Walshon, J., Terranova, G., et al. (1988) · New England Journal of Medicine · doi:10.1056/nejm198803313181301 · Cited by 651
Pozen, M. W., D'Agostino, R. B., Selker, H. P., Sytkowski, P. A., & Hood, W. B. (1984) · New England Journal of Medicine · doi:10.1056/nejm198405173102001 · Cited by 599
Confidence Intervals for Reporting Results of Clinical Trials
SIMON, R. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-105-3-429 · Cited by 416
Unstable angina : diagnosis and management
Braunwald, E. (1994) · Medical Entomology and Zoology · Cited by 332
Lee, T. H., Juarez, G., Cook, E. F., Weisberg, M. C., Rouan, G. W., Brand, D. A., & Goldman, L. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105023241803 · Cited by 262
Fineberg, H. V., Scadden, D., & Goldman, L. (1984) · New England Journal of Medicine · doi:10.1056/nejm198405173102006 · Cited by 242
Detecting acute cardiac ischemia in the emergency department
McCarthy, B. D., Wong, J. B., & Selker, H. P. (1990) · Journal of General Internal Medicine · doi:10.1007/bf02600409 · Cited by 113
Outcome of patients who were admitted to a new short-stay unit to “rule-out” myocardial infarction
Gaspoz, J., Lee, T. H., Cook, E. F., Weisberg, M. C., & Goldman, L. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90734-3 · Cited by 102
Recommended guidelines for in-hospital cardiac monitoring of adults for detection of arrhythmia
Jaffe, A. S., Atkins, J. M., Field, J. M., Francis, C. K., Gibson, R. S., Goldberg, S. J., Guerci, A. D., Mentzer, R. M., Ornato, J. P., Passamani, E. R., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90670-5 · Cited by 75
Selecting the best triage rule for patients hospitalized with chest pain
Weingarten, S. R., Ermann, B., Riedinger, M. S., Shah, P. K., & Ellrodt, A. G. (1989) · The American Journal of Medicine · doi:10.1016/s0002-9343(89)80603-5 · Cited by 71
Cited by
Drew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F. (2004) · Circulation · doi:10.1161/01.cir.0000145144.56673.59 · Cited by 609
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 478
“In 1 prospective study of 2,240 patients admitted to a telemetry unit, patients admitted for syncope (10%) had low rates of unexpected intensive care transfer, andmostwere unrelated to arrhythmic conditions (185).”
BackgroundShen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000499 · Cited by 438
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000498 · Cited by 407
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.003 · Cited by 327
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
“Telemetry findings can be low yield and altered management in only 7% of cases in one study evaluating over 2,000 non-ICU patients (Estrada et al., 1995).”
BackgroundChoosing wisely in pediatric hospital medicine: Five opportunities for improved healthcare value
Quinonez, R. A., Garber, M. D., Schroeder, A. R., Alverson, B. K., Nickel, W., Goldstein, J., Bennett, J. S., Fine, B. R., Hartzog, T. H., McLean, H. S., et al. (2013) · Journal of Hospital Medicine · doi:10.1002/jhm.2064 · Cited by 249
Choosing wisely in adult hospital medicine: Five opportunities for improved healthcare value
Bulger, J., Nickel, W., Messler, J., Goldstein, J., O'Callaghan, J., Auron, M., & Gulati, M. (2013) · Journal of Hospital Medicine · doi:10.1002/jhm.2063 · Cited by 155
“6% of patients on a non-ICU cardiac telemetry unit required telemetric monitoring, and only 7% received modified management as a result of telemetry findings.(36)”
BackgroundDrew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C. E., Swiryn, S., & Hare, G. F. V. (2005) · The Journal of Cardiovascular Nursing · doi:10.1097/00005082-200503000-00003 · Cited by 133
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 133
“Telemetry findings can be low yield and altered management in only 7% of cases in one study evaluating over 2,000 non- ICU patients (Estrada et al., 1995).”
BackgroundDressler, R., Dryer, M. M., Coletti, C., Mahoney, D., & Doorey, A. J. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.4491 · Cited by 102
Atzema, C., Schull, M. J., Borgundvaag, B., Slaughter, G. R. D., & Lee, C. K. (2006) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2005.05.015 · Cited by 98
“Several studies have quest ioned the use of CE M i n a d mi t te d p a t ie n t s w it h c h e s t p a in [6 ] , c it i n g negligible rates of adverse events (AEs) in bvery low-riskQ patients in particula r [7-9] .”
BackgroundTelehealth for Pediatric Cardiology Practitioners in the Time of COVID-19
Chowdhury, D., Hope, K. D., Arthur, L., Weinberger, S. M., Ronai, C., Johnson, J. N., & Snyder, C. S. (2020) · Pediatric Cardiology · doi:10.1007/s00246-020-02411-1 · Cited by 85
Schull, M. J., & Redelmeier, D. A. (2000) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2000.tb02038.x · Cited by 70
Durairaj, L., Reilly, B. M., Das, K., Smith, C. J., Acob, C., Husain, S., Saquib, M., Ganschow, P. S., Evans, A. T., & Mcnutt, R. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00640-9 · Cited by 61
Honarmand, K., Mepham, C., Ainsworth, C. D., & Khalid, Z. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2018.06.005 · Cited by 59
Is telemetry overused? Is it as helpful as thought?
Henriques-Forsythe, M. N., Ivonye, C. C., Jamched, U., Kamuguisha, L. K. K., Olejeme, K. A., & Onwuanyi, A. E. (2009) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.76a.07260 · Cited by 49
Funk, M., Winkler, C. G., May, J. L., Stephens, K., Fennie, K. P., Rose, L. L., Turkman, Y. E., & Drew, B. J. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.07.018 · Cited by 49
When Do Patients Need Admission to a Telemetry Bed?
Chen, E. H., & Hollander, J. E. (2007) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.01.017 · Cited by 53
Kobayashi, L., Parchuri, R., Gardiner, F. G., Paolucci, G. A., Tomaselli, N. M., Al-Rasheed, R. S., Bertsch, K., Devine, J., Boss, R. M., Gibbs, F. J., et al. (2012) · BMJ Quality & Safety · doi:10.1136/bmjqs-2012-001134 · Cited by 49
Hollander, J. E., Valentine, S. M., McCuskey, C. F., & Brogan, G. X. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00057-x · Cited by 44
Hollander, J. E., Sites, F. D., Pollack, C. V., & Shofer, F. S. (2004) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(03)00719-4 · Cited by 43
Is Telemetry Monitoring Necessary in Low-Risk Suspected Acute Chest Pain Syndromes?
Snider, A., Papaleo, M., BELDNER, S. J., Park, C., Katechis, D., Galinkin, D., & Fein, A. M. (2002) · CHEST Journal · doi:10.1378/chest.122.2.517 · Cited by 43
Evaluation of guidelines for the use of telemetry in the non-intensive-care setting
Estrada, C. A., Rosman, H., Prasad, N. K., Battilana, G., Alexander, M., Held, A. C., & Young, M. (2000) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2000.112188.x · Cited by 41
Self-citationCardiorespiratory and Pulse Oximetry Monitoring in Hospitalized Children: A Delphi Process
Schondelmeyer, A. C., Dewan, M. L., Brady, P. W., Timmons, K. M., Cable, R., Britto, M. T., & Bonafide, C. P. (2020) · PEDIATRICS · doi:10.1542/peds.2019-3336 · Cited by 47
Utility of in-hospital cardiac remote telemetry in patients with unexplained syncope
Benezet-Mazuecos, J., Ibanez, B., Rubio, J. M., Navarro, F., Martin, E., Romero, J., & Farre, J. (2007) · Europace · doi:10.1093/europace/eum239 · Cited by 38
“8% of the patients were transferred to a CCU because of an arrhythmia identified by telemetry.(11) These studies apparently showed a disappointing role of CR-TEL in the management of hospitalized patients.”
BackgroundMethodLarson, T. S., & Brady, W. J. (2008) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2007.12.003 · Cited by 42
“Physicians often overestimate the value of electrocardiographic monitoring; they must realize that such surveillance is not full proof, especially outside of an adequately staffed unit [14,32].”
BackgroundCantillon, D. J., Loy, M., Burkle, A., Pengel, S., Brosovich, D., Hamilton, A., Khot, U. N., & Lindsay, B. D. (2016) · JAMA · doi:10.1001/jama.2016.10258 · Cited by 35
Hilbel, T., Helms, T. M., Mikus, G., Katus, H. A., & Zugck, C. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0017-2 · Cited by 35
Over-monitoring and alarm fatigue: For whom do the bells toll?
Feder, S. L., & Funk, M. (2013) · Heart & Lung · doi:10.1016/j.hrtlng.2013.09.001 · Cited by 34
Telemetry outside critical care units: Patterns of utilization and influence on management decisions
Sivaram, C. A., Summers, J. H., & Ahmed, N. (1998) · Clinical Cardiology · doi:10.1002/clc.4960210709 · Cited by 31
Nurse Responses to Physiologic Monitor Alarms on a General Pediatric Unit
Schondelmeyer, A. C., Daraiseh, N. M., Allison, B., Acree, C., Loechtenfeldt, A. M., Timmons, K. M., Mangeot, C., & Brady, P. W. (2019) · Journal of Hospital Medicine · doi:10.12788/jhm.3234 · Cited by 27
Barriers and Facilitators to Guideline-Adherent Pulse Oximetry Use in Bronchiolitis
Wolk, C. B., Schondelmeyer, A. C., Barg, F. K., Beidas, R. S., Betterncourt, A., Brady, P. W., Brent, C. R., Eriksen, W., Kinkler, G., Landrigan, C. P., et al. (2020) · Journal of Hospital Medicine · doi:10.12788/jhm.3535 · Cited by 23
Evaluation of the Appropriateness and Outcome of In-Hospital Telemetry Monitoring
Fålun, N., Nordrehaug, J. E., Hoff, P. I., Langørgen, J., Moons, P., & Norekvål, T. M. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.069 · Cited by 25
“Atrial fibrillation or flutter 153 (39) 33 (35) 90 (38) 30 (50) Nonsustained ventricular tachycardia 82 (21) 18 (19) 56 (24) 8 (13) Sinus tachycardia 40 (10) 12 (13) 24 (10) 4 (7) Sinus bradycardia 36 (9) 8 (9) 24 (10) 4 (7) Supraventricular tachycardia 18 (5) 6 (6) 7 (3) 5 (8) Second degree AV block or complete heart…”
BackgroundInfluentialGatien, M., Perry, J. J., Stiell, I. G., Wielgosz, A. T., & Lee, J. S. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.02.004 · Cited by 25
Potential of Missing Life-Threatening Arrhythmias After Limiting the Use of Cardiac Telemetry
Kansara, P., Jackson, K., Dressler, R. M., Weiner, H., Kerzner, R., Weintraub, W. S., & Doorey, A. J. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.2387 · Cited by 20
Sandgren, P. S. (2004) · Ethos · doi:10.1525/eth.2004.32.1.110 · Cited by 23
Inpatient Cardiac Telemetry Monitoring: Are We Overdoing It?
Kanwar, M. K., Fares, R., Minnick, S., Rosman, H., & Saravolatz, L. I. I. (2008) · Cited by 18
Self-citationSaleem, M. A., McClung, J. A., Aronow, W. S., & Kannam, H. (2005) · The Journals of Gerontology Series A · doi:10.1093/gerona/60.5.605 · Cited by 21
Evaluation of Telemetry Utilization, Policy, and Outcomes in an Inner-City Academic Medical Center
Ivonye, C., Ohuabunwo, C., Henriques-Forsythe, M., Uma, J., Kamuguisha, L. K., Olejeme, K., & Onwuanyi, A. (2010) · Journal of the National Medical Association · doi:10.1016/s0027-9684(15)30637-4 · Cited by 15
Non-critical care telemetry and in-hospital cardiac arrest outcomes
Mohammad, R., Shah, S., Donath, E. M., Hartmann, N., Rasmussen, A., Isaac, S., & Borzak, S. L. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.02.003 · Cited by 17
“Our findings contradict the majority of current evidence reported on telemetry use and its impact on cardiac arrests in non-critical patients [6–11].”
BackgroundResultChen, S., Palchaudhuri, S., Johnson, A. E., Trost, J., Ponor, I. L., & Zakaria, S. (2017) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12708 · Cited by 17
Does in-Patient ECG Monitoring have an Impact on Medical Care in Chronic Heart Failure Patients?
Opasich, C., Capomolla, S., Riccardi, P. G., Febo, O., Forni, G., Cobelli, F., & Tavazzi, L. (2000) · European Journal of Heart Failure · doi:10.1016/s1388-9842(00)00057-x · Cited by 15
Guideline‐based intervention to reduce telemetry rates in a large tertiary centre
Ramkumar, S., Tsoi, E. H., Raghunath, A., Dias, F. F., Suen, C. L. W., Tsoi, A. H., & Mansfield, D. R. (2017) · Internal Medicine Journal · doi:10.1111/imj.13452 · Cited by 15
Behind the Monitor—The Trouble With Telemetry
Chen, S., & Zakaria, S. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.0837 · Cited by 13
A Nurse Practitioner Intervention Model to Maximize Efficient Use of Telemetry Resources
Gross, P. A., Patriaco, D., McGuire, K., Skurnick, J., & Teichholz, L. E. (2002) · The Joint Commission Journal on Quality Improvement · doi:10.1016/s1070-3241(02)28060-8 · Cited by 14
Validation of a tool to safely triage selected patients with chest pain to unmonitored beds
Sultana, R., Kerr, D. C., Kelly, A., & Cameron, P. A. (2002) · Emergency Medicine Australasia · doi:10.1046/j.1442-2026.2002.00380.x · Cited by 13
Palchaudhuri, S., Chen, S., Clayton, E., Accurso, A. J., & Zakaria, S. (2017) · Journal of Hospital Medicine · doi:10.12788/jhm.2754 · Cited by 12
Patient and Nurse-Related Implications of Remote Cardiac Telemetry
Billinghurst, F., Morgan, B., & Arthur, H. M. (2003) · Clinical Nursing Research · doi:10.1177/1054773803258998 · Cited by 13
“Estrada et al. (1995) prospectively recorded the number of admissions to critical care and the mortality of 2,240 telemetry patients to assess the role of telemetry for guiding medical management decisions.”
BackgroundKelly, A., & Kerr, D. C. (2004) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2004.00650.x · Cited by 11
Singer, A. J., Visram, F., Shembekar, A., Khwaja, M., & Viccellio, A. W. (2005) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2005.tb00808.x · Cited by 10
Blomkalns, A. L., & Gibler, W. B. (2004) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2003.10.033 · Cited by 11
Is telemetry useful in evaluating chest pain patients in an observation unit?
Grossman, S. A., Shapiro, N. I., Mottley, J. L., Sánchez, L. D., Ullman, E. A., & Wolfe, R. E. (2011) · Internal and Emergency Medicine · doi:10.1007/s11739-011-0648-x · Cited by 11
“Hollander et al. [ 1 ] reported that 1,029 patient’s chest pain patients admitted to the hospital with normal or nonspecific ECGs, in which only four (0.9%) patients developed any dysrhythmia.”
BackgroundResultInfluentialTiongson, J. E., Robin, J. C., Chana, A., Shin, D. D., & Gheorghiade, M. (2006) · Acute Cardiac Care · doi:10.1080/17482940600934192 · Cited by 9
Chahine, J., Thapa, B., Gosai, F., Abdelghaffar, B., Ashi, S. I. A., Maroo, A. P., Alappan, N., & Gopalakrishna, K. N. (2019) · Cureus · doi:10.7759/cureus.4311 · Cited by 12
“found that less than 1% of patients had life-threatening arrhythmias on cardiac telemetry [8].”
BackgroundTelemetry Monitoring in Acute and Critical Care
Martin, N., & Hendrickson, P. (1999) · Critical Care Nursing Clinics of North America · doi:10.1016/s0899-5885(18)30179-5 · Cited by 9
Appropriate Use of Telemetry Monitoring in Hospitalized Patients
Chen, E. H. (2013) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-013-0030-6 · Cited by 9
“[15] showed that telemetry events led to a change in management in 7 % of the monitored patients (i.”
BackgroundCost-effectiveness in Clinical Cardiology
Willens, H. J., Chakko, S. C., Simmons, J. D., & Kessler, K. M. (1996) · CHEST Journal · doi:10.1378/chest.109.5.1359 · Cited by 8
Lessons Learned from Efforts to Reduce Overuse of Cardiac Telemetry Monitoring
Chakravarthy, R., Goggins, K. M., Leverenz, D. L., Trumbo, S. P., Kripalani, S. B., & Limper, H. M. (2020) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2020.05.001 · Cited by 8
Dhillon (2012) · Cardiology Research · doi:10.4021/cr129w · Cited by 12
“Although many institutions have adopted the American College of Cardiology (ACC) guidelines for telemetry, few clinical studies have systematically measured the value of telemetry monitoring guidelines [6-12].”
Family Perspectives on Continuous Monitor Use in a Children’s Hospital: A Qualitative Study
Schondelmeyer, A. C., Jenkins, A., Vaughn, L. M., & Brady, P. W. (2021) · Hospital Pediatrics · doi:10.1542/hpeds.2021-005949 · Cited by 6
Blomkalns, A. L., & Gibler, W. B. (2004) · PubMed · doi:10.1016/s0196064403011090 · Cited by 8
Telemetry or not telemetry: a great leap forward or a waste of resources?
Goldman, L. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00679-3 · Cited by 5
Interactive Multimodal Curriculum on Use and Interpretation of Inpatient Telemetry
Chuzi, S. E., Cantey, E. P., Unger, E. D., Rosenthal, J. E., Didwania, A. K., McGaghie, W. C., & Prenner, S. B. (2018) · MedEdPORTAL · doi:10.15766/mep_2374-8265.10730 · Cited by 4
Caglar, S., & Leffler, S. M. (2006) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2006.01.028 · Cited by 4
“In another study, Estrada and colleagues [8] asserted that bpatients who did deteriorate were recognized clinically without appreciable contribution from the monitoring processQ [9].”
BackgroundPerkins, J., McCurdy, M. T., Vilke, G. M., & Al-Marshad, A. (2013) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2013.08.098 · Cited by 4
Sharain, K., Vasile, V. C., & Jaffe, A. S. (2016) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872615627709 · Cited by 4
Evaluation of the patient with chest pain: Are the bells and whistles evidence based?
Hollander, J. E. (2003) · Annals of Emergency Medicine · doi:10.1067/mem.2003.79 · Cited by 4
Cost-effectiveness in Clinical Cardiology
Simmons, J. D., Chakko, S. C., Willens, H. J., & Kessler, K. M. (1996) · CHEST Journal · doi:10.1378/chest.110.1.256 · Cited by 4
Indication‐specific event rates among hospitalized patients undergoing continuous cardiac monitoring
Cantillon, D. J., Burkle, A., Kirkwood, D., Loy, M., Amuthan, R., Pengel, S., Tote, J., MORRIS, W. M., Houghtaling, P. L., Hamilton, A. C., et al. (2019) · Clinical Cardiology · doi:10.1002/clc.23244 · Cited by 3
A Call for Evidence-Based Telemetry Monitoring
Najafi, N. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.3502 · Cited by 3
Discovering the cause of syncope: A guide to the focused evaluation
Hauer, K. E. (2003) · Postgraduate Medicine · doi:10.3810/pgm.2003.01.1356 · Cited by 3
Chen, E. H., & Mills, A. M. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2005.07.010 · Cited by 2
McIntyre, W. F., Liu, S., & Garber, P. J. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.03.020 · Cited by 2
Is Telemetry Monitoring Useful in Patients Admitted With Suspected Acute Coronary Syndrome?
Perkins, J., Voore, N. K., Patel, J., Sanna, S., Mann, E., Zakaria, S., & Gozu, A. (2017) · American Journal of Medical Quality · doi:10.1177/1062860617690803 · Cited by 1
“3%) patients required transfer to the intensive care unit for management of clinically relevant dysrhythmias.(12) In another study of 1029 patients with negative initial cardiac enzymes and normal ECGs, 1.”
MethodDecreasing unnecessary use of continuous cardiac monitoring (telemetry) in hospitalised patients
Silverstein, W. K., Chang, I. Y., Sreenivasan, S., & Dhruva, S. S. (2024) · BMJ · doi:10.1136/bmj-2023-077499 · Cited by 3
Clinician Perspectives on Continuous Monitor Use in a Children’s Hospital: A Qualitative Study
Schondelmeyer, A. C., Sauers‐Ford, H. S., Touzinsky, S. M., Brady, P. W., Britto, M. T., Molloy, M. J., Simmons, J. M., Cvach, M. M., Shah, S. S., Vaughn, L. M., et al. (2024) · Hospital Pediatrics · doi:10.1542/hpeds.2023-007638 · Cited by 1
Usefulness of a "satellite", long-term 12-lead ECG in cyberspace
Khoór, S., Nieberl, J., Fudedi, K., & Kail, E. (2003) · Computers in cardiology · doi:10.1109/cic.1999.825898 · Cited by 1
Choosing and Evaluating Outcome Measures for Clinical Studies of Medical Devices
Kunitz, S. C., Gargano, M., & Kozloff, R. C. (1998) · Humana Press eBooks · doi:10.1007/978-1-4757-2756-2_3
Supraventricular Tachycardia and the Use of Telemetry in Hospitalized Patients
McCormick, I. (2014) · Hospital Medicine Clinics · doi:10.1016/j.ehmc.2014.09.006
Jaffe, A. S. (2000) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2000.tb02047.x
Telemetry – Heartbeat of the system
Akhtar, N., & Cooke, M. W. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2013.04.002
2009 Lifelong Learning And Self-Assessment Study Guide
Williford, R., Alvarez, L., & Pai, J. (2009)
The Dos and Don'ts of Telemetry Monitoring: A Telemetry Director's Top 10 Misuses, Explained
Winawer, N. H., & Sfhm (2017) · Journal watch · doi:10.1056/nejm-jw.na44560
Bohossian, H. B., & An, P. G. (2017) · Hospital Medicine Clinics · doi:10.1016/j.ehmc.2017.03.001
Intensive Care Considerations of the Cancer Patient
Botdorf, J., & Nates, J. L. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-69584-8.00039-6
Improving Telemetry use in the Acute Assessment Unit
3, I. M. T., Timmons, P., Reid, L., Clare, K., Beckett, D. J., Thomson, T., & Fabisiak, L. (2024) · Acute Medicine Journal · doi:10.52964/amja.0969
A Multimodal Quality Improvement Initiative to Reduce Non-ICU Telemetry Overutilization
Janabi, T. A., Anderson, J., Ali, M., Mand, K., & Jain, D. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.109232
Metadata
- Authors
- Estrada, C. A., Rosman, H. S., Prasad, N. K., Battilana, G., Alexander, M., Held, A. C., & Young, M. J.
- Affiliations
- Henry Ford Hospital (US)
- Corresponding author
- Rosman, Howard S.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 76
- Issue
- 12
- Pages
- 960-965
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2013105064
- Cited by
- 90
- References
- 17
- Citations by year
- 2026: 1 · 2024: 3 · 2022: 1 · 2021: 1 · 2020: 5 · 2019: 3 · 2018: 2 · 2017: 13 · 2016: 3 · 2015: 3 · 2014: 3 · 2013: 7 · 2012: 2
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- telemetry monitoring, non-intensive care units, arrhythmia detection, ICU transfer, mortality, chest pain syndrome, heart failure, syncope, cardiac revascularization, clinical deterioration
- MeSH terms
- Aged, Decision Making, Female, Heart Diseases, Hospital Units, Humans, Male, Middle Aged, Prospective Studies, Telemetry, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.