CoChat

A critical evaluation of laboratory tests in acute pancreatitis

Yadav, D · 2002 · The American Journal of Gastroenterology
Cited by 375

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

An ideal laboratory test in the evaluation of a patient with acute pancreatitis (AP) should, in addition to accurately establishing the diagnosis of AP, provide early assessment of its severity and identify the etiology. None of the tests available today meet all these criteria, and presently there is no biochemical test that can be considered the "gold standard" for the diagnosis and assessment of severity of AP. In the diagnosis of AP, serum amylase and lipase remain important tests. Advantages of amylase estimation are its technical simplicity, easy availability, and high sensitivity. However, its greatest disadvantage is its low specificity. A normal amylase would usually exclude the diagnosis of AP, with the exception of AP secondary to hyperlipidemia, acute exacerbation of chronic pancreatitis, and when the estimation of amylase is delayed in the course of the disease. The major advantage of lipase is an increased sensitivity in acute alcoholic pancreatitis and in patients who initially present to the emergency room days after the onset of the disease, as lipase remains elevated longer than amylase. Although once considered to be specific for AP, nonspecific elevations of lipase have been reported in almost as many disorders as amylase, thus decreasing its specificity. Simultaneous estimation of amylase and lipase does not improve the accuracy. Other enzymes for the diagnosis of AP--pancreatic isoamylase, immunoreactive trypsin, and elastase--are more cumbersome and expensive and have no clear role in the diagnosis of AP. No enzyme assay has a predictive role in determining the severity or etiology of AP. Once the diagnosis of AP is established, daily measurements of enzymes have no value in assessing the clinical progress of the patient or ultimate prognosis and should be discouraged. A host of new serological and urinary markers have been investigated in the last few years. Their main use is in predicting the severity of AP. At present, serum C-reactive protein at 48 h is the best available laboratory marker of severity. Urinary trypsinogen activation peptides within 12-24 h of onset of AP are able to predict the severity but are not widely available. Serum interleukins 6 and 8 seem promising but remain experimental.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0002-9270(02)04122-9

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 375

Metadata

Authors
Yadav, D.
Venue
The American Journal of Gastroenterology
Published
2002-06
Volume
97
Issue
6
Pages
1309-1318
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2041522924
Cited by
375
References
45
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.