A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope
Abstract
Background The initial management of syncope or presyncope typically involves short-term cardiac monitoring using a Holter monitor. A loop recorder is used to extend the period of monitoring to increase the probability of obtaining a symptom-rhythm correlation. Loop recorders and Holter monitors are both used commonly, but their utility has not been compared prospectively. Methods Patients with syncope or presyncope referred for a Holter monitor or a loop recorder were assigned randomly to receive either a 48-hour Holter monitor or a loop recorder for 1 month as an initial diagnostic strategy. If the initial strategy was unsuccessful, patients were offered crossover to the alternate strategy. Results One hundred patients (mean [+/- SD] age, 56 +/- 20 years; 44 women) with syncope (n = 21), presyncope (n = 29), or both (n = 50) were enrolled. Of the 49 patients assigned randomly to an external loop recorder first, 31 (63%) had an arrhythmia identified or excluded, versus 12 (24%) of 51 patients assigned to a Holter monitor initially (P Conclusion Loop recorders have a much higher diagnostic yield for patients with syncope or presyncope as compared with Holter monitors. The utility of loop recorders is limited by some patients' inability to operate them correctly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 1 trial, the overall probability of obtaining a symptom-rhythm correlation increased from 22% to 56% for 48-hr Holters compared to 1 month of ECG loop recording (Sivakumaran et al., 2003).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Sivakumaran et al., 2003
In the citing paper
“It has been reported that the diagnostic rate of ECG monitoring for syncope using the ELR (55%) was superior to that of Holter ECG (22%) [11].”
From Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms (2017) · cites this paper as [11]
Citations
Cites
Robinson, R. (1993) · BMJ · doi:10.1136/bmj.307.6907.793 · Cited by 816
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Self-citationCLINICAL GUIDELINE: Diagnosing Syncope: Part 2: Unexplained Syncope
Linzer, M., Yang, E. H., Estes, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-1-199707010-00014 · Cited by 313
Prospective evaluation of patients with syncope: a population-based study
Sarasin, F. P., Louis-Simonet, M., Carballo, D., Slama, S., Rajeswaran, A., Metzger, J. T., Lovis, C., Unger, P.-F., & Junod, A.-F. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00797-5 · Cited by 282
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490180085031 · Cited by 229
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
Bass, E. B. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00390170103022 · Cited by 156
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 478
“External loop recorders are also limited an external loop recorder over Holtermonitoring stems from a longer than Holter monitoring (149,153) and may offer a diagnosis after a iagnostic yield of an external loop recorder may be lower than that of vasive strategy is reasonable as a first approach.”
BackgroundSelf-citationShen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000499 · Cited by 438
“2003 12867227 (75) Aim: To compare diagnostic utility of ELR to Holter in determining arrhythmic cause of syncope.”
MethodSelf-citation
Metadata
- Authors
- Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C.
- Affiliations
- Western University (CA)
- Corresponding author
- Krahn, Andrew D
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 115
- Issue
- 1
- Pages
- 1-5
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2012123493
- Cited by
- 160
- References
- 23
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 4 · 2023: 7 · 2022: 4 · 2021: 8 · 2020: 2 · 2019: 7 · 2018: 10 · 2017: 15 · 2016: 6 · 2015: 3 · 2014: 9 · 2013: 13 · 2012: 4
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- syncope, presyncope, loop recorder, Holter monitor, cardiac arrhythmias, arrhythmia diagnosis
- MeSH terms
- Female, Humans, Male, Middle Aged, Prospective Studies, Severity of Illness Index, Syncope, Time Factors, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope. https://app.cochat.ai/papers/10.1016/s0002-9343(03)00233-x
- The paper
- Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003). A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope. The American Journal of Medicine. https://doi.org/10.1016/s0002-9343(03)00233-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.