A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope
The DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index.
Abstract
Background The initial management of syncope or presyncope typically involves short-term cardiac monitoring using a Holter monitor. A loop recorder is used to extend the period of monitoring to increase the probability of obtaining a symptom-rhythm correlation. Loop recorders and Holter monitors are both used commonly, but their utility has not been compared prospectively. Methods Patients with syncope or presyncope referred for a Holter monitor or a loop recorder were assigned randomly to receive either a 48-hour Holter monitor or a loop recorder for 1 month as an initial diagnostic strategy. If the initial strategy was unsuccessful, patients were offered crossover to the alternate strategy. Results One hundred patients (mean [+/- SD] age, 56 +/- 20 years; 44 women) with syncope (n = 21), presyncope (n = 29), or both (n = 50) were enrolled. Of the 49 patients assigned randomly to an external loop recorder first, 31 (63%) had an arrhythmia identified or excluded, versus 12 (24%) of 51 patients assigned to a Holter monitor initially (P Conclusion Loop recorders have a much higher diagnostic yield for patients with syncope or presyncope as compared with Holter monitors. The utility of loop recorders is limited by some patients' inability to operate them correctly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 1 trial, the overall probability of obtaining a symptom-rhythm correlation increased from 22% to 56% for 48-hr Holters compared to 1 month of ECG loop recording (Sivakumaran et al., 2003).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Sivakumaran et al., 2003
In the citing paper
“It has been reported that the diagnostic rate of ECG monitoring for syncope using the ELR (55%) was superior to that of Holter ECG (22%) [11].”
From Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms (2017) · cites this paper as [11]
Citations
Cites
Robinson, R. (1993) · BMJ · doi:10.1136/bmj.307.6907.793 · Cited by 816
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Self-citationCLINICAL GUIDELINE: Diagnosing Syncope: Part 2: Unexplained Syncope
Linzer, M., Yang, E. H., Estes, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-1-199707010-00014 · Cited by 313
Prospective evaluation of patients with syncope: a population-based study
Sarasin, F. P., Louis-Simonet, M., Carballo, D., Slama, S., Rajeswaran, A., Metzger, J. T., Lovis, C., Unger, P.-F., & Junod, A.-F. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00797-5 · Cited by 282
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490180085031 · Cited by 229
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
Bass, E. B. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00390170103022 · Cited by 156
Cited by
Items 101–159 of 159
Serious outcomes among emergency department patients with presyncope: A systematic review
Mirfazaelian, H., Stiell, I. G., Masoumi, R., Garjani, K., & Thiruganasambandamoorthy, V. (2024) · Academic Emergency Medicine · doi:10.1111/acem.14943 · Cited by 4
Bouzas‐Mosquera, A., Sánchez‐Fernández, G., Barbeito‐Caamaño, C., Broullón, F. J., Martínez, D., Yáñez, J. C., Álvarez‐García, N., & Vázquez‐Rodríguez, J. M. (2015) · Journal of the American Geriatrics Society · doi:10.1111/jgs.13846 · Cited by 4
Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.008 · Cited by 5
Diagnostic and prognostic efficiency of 24-hour Holter monitoring in patients with syncope
Barbeito‐Caamaño, C., Sánchez‐Fernández, G., Bouzas‐Mosquera, A., Broullón, F. J., Álvarez‐García, N., & Vázquez‐Rodríguez, J. M. (2016) · Medicina Clínica (English Edition) · doi:10.1016/j.medcle.2016.09.028 · Cited by 4
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 6
Self-citationBrandes, A., & Bethge, K.-P. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0010-9 · Cited by 10
Electrocardiographic monitoring in the assessment of unexplained syncope
Sarasin, F. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00306-1 · Cited by 4
Hanninen, M., Klein, G. J., & Manlucu, J. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.02.010 · Cited by 4
Self-citationAlotaibi, A., Alakhfash, G. A., Alakhfash, A. A., Mahmoud, T., Alakhfash, A. A., Qwaee, A. A., & Mesned, A. A. (2022) · Cureus · doi:10.7759/cureus.25667 · Cited by 3
“Even in the presence of significant arrhythmia, the rhythm abnormality might not happen during the recording period [6].”
BackgroundVanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.003 · Cited by 3
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 4
Self-citationAmbulatory cardiac rhythm monitoring
Rao, A., Lomax, S., Ramsdale, K. A., & Ramsdale, D. (2007) · British Journal of Hospital Medicine · doi:10.12968/hmed.2007.68.3.22848 · Cited by 4
Klenck, C. (2007) · Current Sports Medicine Reports · doi:10.1007/s11932-007-0008-9 · Cited by 4
Ray, J. C., Kusumoto, F. M., & Goldschlager, N. (2014) · Journal of Intensive Care Medicine · doi:10.1177/0885066614552988 · Cited by 3
“Recent research on the use of ELRs has found their use to be more applicable for individuals with frequent presyncope or palpitations.(100) Implantable loop recorders are subcutaneously implanted devices designed to continuously monitor cardiac rhythms Figure 1.”
BackgroundCaracterísticas clínicas de pacientes llevados a monitoría externa de eventos
Carvajal, J. J., Clavijo, C., Bautista, L. J., & Mora, G. (2014) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2013.11.001 · Cited by 2
Hussein, A. A., & SALIARIS, A. P. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.07.014 · Cited by 2
An introduction to ambulatory electrocardiography
Richley, D. (2010) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2010.5.1.46025 · Cited by 2
Syncope: Approach to diagnosis
Anil, O. (2016) · Journal of Clinical and Preventive Cardiology · doi:10.4103/2250-3528.191099 · Cited by 2
Diagnosis of Arrhythmias with Non-invasive Tools
Sullivan, R. M., Li, W. W., Kendig, A. C., & Olshansky, B. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-161-5_5 · Cited by 4
Srivatsav, A., Thompson, Z., Bruno, M. A., Stephens, S. B., Gutierrez, M. E., Miyake, C. Y., Morris, S. A., Pham, T. D., Valdés, S. O., Kim, J. J., et al. (2024) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.15087 · Cited by 1
Update on syncope in the older person – a clinical review
Mappilakkandy, R. K., & Edwards, I. (2012) · Reviews in Clinical Gerontology · doi:10.1017/s0959259812000202 · Cited by 1
Ambulatory Electrocardiography
Flinders, D., & Akin, S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-05267-2.00087-x · Cited by 1
[Artificial intelligence in wearable electrocardiogram monitoring].
Wang, X., Li, Q., Ma, C., Zhang, S., Lin, Y., Li, J., & Liu, C. (2023) · PubMed Central · doi:10.7507/1001-5515.202301032 · Cited by 4
Long-term Monitoring to Detect Risk of Sudden Cardiac Death in Inherited Arrhythmia Patients
Domain, G., Steinberg, C., Davies, B., Strubé, C., Roberts, J. D., Simpson, C., & Krahn, A. D. (2024) · CJC Open · doi:10.1016/j.cjco.2024.05.007 · Cited by 1
Self-citationCURRENT METHODS OF OUTPATIENT ELECTROCARDIOGRAPHIC MONITORING. CLINICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2017-11-2-58-73 · Cited by 4
Krahn, A. D., Yee, R., Skanes, A. C., & Klein, G. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00066-3 · Cited by 1
Self-citationKida, H., Kawasaki, M., Kikuchi, Y., Okada, K., Watanabe, T., & Yamada, T. (2022) · Journal of Arrhythmia · doi:10.1002/joa3.12782 · Cited by 1
Fahey, T. P., & Schroeder, K. (2004) · Europe PMC (PubMed Central) · Cited by 4
Ambulatory Electrocardiography, Transient Event Monitors, and Continuous Loop Recorders
Kreeger, R. W., Brooks, J., & Movahed, A. (2008) · Springer eBooks · doi:10.1007/978-3-540-78674-0_9
Value and Limitations of Ambulatory Electrocardiographic Monitoring
Krahn, A. D. (2007) · Wiley eBooks · doi:10.1002/9780470692639.ch10
Self-citationEffiziente Synkopenabklärung: Wann soll der implantierbare Loop-Rekorder verwendet werden?
Pezawas, T., & Schmidinger, H. (2004) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 1
Investigation of collapse in small animals
Patteson, M. W. (2014) · Companion animal · doi:10.12968/coan.2014.19.10.500
Evaluation of arrhythmias beyond ECG.
Gupta, S. B., Limaye, H., Motorwla, R., Kothari, S., & Lokhandwala, Y. Y. (2007) · PubMed
Gómez-Preciado, F., Fernández, J. A. S., Gil, A., & Cardona, M. F. (2011) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/s0304-5412(11)70193-7
Comparison of Various Cardiac Event Recorders Clinically Available in Japan
Nakamura, H., Yasuda, S., Odashiro, K., Kaji, Y., & Maruyama, T. (2007) · JOURNAL OF HEALTH SCIENCE · doi:10.15017/10773
Implantierbare Loop-Rekorder in der Synkopendiagnostik
Kaess, B. M., & Ehrlich, J. R. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0476-9
Brignole, M., Blanc, J., Sutton, R., & Moyá, A. (2009)
Arrhythmias in Older People: Focusing on Atrial Fibrillation. Epidemiology and impact on daily Life.
Lindberg, T. (2017) · Lund University Publications (Lund University) · Cited by 3
Assessment of the Patient With a Cardiac Arrhythmia
Das, M. K., & Zipes, D. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00059-6
Krahn, A. D., Yee, R. K., Skanes, A. C., & Klein, G. J. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00064-9
Self-citationIndicazioni all’utilizzo diagnostico del loop recorder impiantabile ed esterno
Brignole, M., Vardas, P. E., Hoffman, E., Huikuri, H. V., Moyá, A., Ricci, R. P., Sulke, N., & Wieling, W. (2011) · Giornale Italiano di Aritmologia e Cardiostimolazione
Olshansky, B., Hu, D., Khanh, P. Q., Pham, N. H., Phuoc, T. T., & Nguyen, T. N. (2007) · Wiley eBooks · doi:10.1002/9780470750858.ch13
Gould, P. A., Klein, G. J., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2008) · Handbook of clinical neurology · doi:10.1016/s0072-9752(07)01714-9
Self-citationSubbiah, R. N., Chia, P., Leong‐Sit, P., Gula, L. J., Skanes, A. C., Yee, R. K., Klein, G. J., & Krahn, A. D. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4978-1_15
Self-citationBrignole, M., Blanc, J., Sutton, R., & Moya‐Mitjans, À. (2009) · doi:10.1093/med/9780199566990.003.026
KRUMERMAN, A. K., & Fisher, J. D. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00103-5
Ambulatory Electrocardiography
Rho, R. W., & Page, R. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00071-5
An Approach to Cardiac Syncope in the Elderly Patient
Roy, P., Walsh, K. E., & Goldberger, Z. D. (2022) · Current Geriatrics Reports · doi:10.1007/s13670-022-00376-y · Cited by 1
Arrhythmia Management in the Elderly
Wallace, R. L., & Calkins, H. G. (2023) · Contemporary cardiology · doi:10.1007/978-3-031-16594-8_6
Contemporary wearable and handheld technology for the diagnosis of cardiac arrhythmias in Singapore
Chia, P., Tan, K. W. K., Ng, S., & Foo, D. C. G. (2023) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2023-048
“[3] However, the usefulness of trans‑telephonic ECG recorders is limited by the patients’ compliance to wearing the electrodes and their ability to operate the device correctly during symptoms.”
Homme, J. L., Kranz, L. A., House, M., & Greenmyer, J. R. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.04.012
Nuvvula, S., & Makaryus, A. N. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2514005
“Some devices are superior to others in certain aspects such as how ILRs had a higher correlation between symptoms and rhythm detection compared to Holter monitors [33].”
InfluentialA study of the clinical usefulness of the eMEMO ®
Nakayama, H., Watanabe, N., Tsukamoto, M., Mori, M., Nakakubo, E., Watanabe, S., & Taniguchi, M. (2025) · Journal of Arrhythmia · doi:10.1002/joa3.70137
“14 Automatic detection of arrhythmia has been reported to be very effective, and there are many cases in which asymptomatic arrhythmias were efficiently detected.”
Incidence and Predictors of Symptom-Arrhythmia Association During Outpatient Holter Monitoring
Saraiya, A., Corsi, D. R., Farhan, S., Hazlewood, C., Qiu, G., & Pavri, B. B. (2025) · Cureus · doi:10.7759/cureus.96201
Benabbas, R., Zehtabchi, S., Wakai, A., Allen, R. W., deSouza, I. S., Richards, R. J., Curley, D., Dunne, E., & Sinert, R. H. (2025) · Academic Emergency Medicine · doi:10.1111/acem.70175
Prolonged Ambulatory ECG Diagnostic Monitoring … Current and Evolving Indications
Brignole, M., & Benditt, D. G. (2010) · Springer eBooks · doi:10.1007/978-0-85729-201-8_8
Neto, A. C. L., Mezzalira, R., & Bittar, R. S. M. (2026) · Brazilian Journal of Otorhinolaryngology · doi:10.1016/j.bjorl.2026.101822 · Cited by 1
“37 However, within this conceptual framework, arrhythmias that cause symptoms of VB hypoflow due to thromboembolism, such as atrial fibrillation, must be considered “ siltation ” , not “ tidal effect ” .”
Ambulatory Electrocardiography Modalities in Pediatric Arrhythmia Detection and Management
Hsu, Y. T., Tseng, W. C., Hsu, Y. L., Wu, M. H., Lu, C. W., Wu, K. L., Peng, W., & Chiu, S. N. (2026) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2026.4910
Metadata
- Authors
- Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C.
- Affiliations
- Western University (CA)
- Corresponding author
- Krahn, Andrew D
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 115
- Issue
- 1
- Pages
- 1-5
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2012123493
- Semantic Scholar
- 43083d3e4ec9bd42fda608878f3c8a43e5afa4ad
- Cited by
- 160
- References
- 23
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 4 · 2023: 7 · 2022: 4 · 2021: 8 · 2020: 2 · 2019: 7 · 2018: 10 · 2017: 15 · 2016: 6 · 2015: 3 · 2014: 9 · 2013: 13 · 2012: 4
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- syncope, presyncope, loop recorder, Holter monitor, cardiac arrhythmias, arrhythmia diagnosis
- MeSH terms
- Female, Humans, Male, Middle Aged, Prospective Studies, Severity of Illness Index, Syncope, Time Factors, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.