High concentration of dexamethasone in aqueous and vitreous after subconjunctival injection
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olsen, T. W., Edelhauser, H. F., Lim, J. I., & Geroski, D. H. (1995) · PubMed · Cited by 230
(1989) · Elsevier eBooks · doi:10.1016/c2013-0-06552-8 · Cited by 181
Sears, M. L. (1984) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-69222-2 · Cited by 170
Weijtens, O., van der Sluijs, F. A., Schoemaker, R. C., Lentjes, E. G. W. M., Cohen, A. F., Romijn, F. P. H. T. M., & MEURS, J. C. V. (1997) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)70131-x · Cited by 115
Self-citationPenetration of synthetic corticosteroids into human aqueous humour
McGhee, C. N. J., Watson, D. G., Midgley, J. M., Noble, M. B., Dutton, G. N., & Fern, A. I. (1990) · Eye · doi:10.1038/eye.1990.70 · Cited by 101
Dexamethasone Concentration in Vitreous and Serum After Oral Administration
Weijtens, O., Schoemaker, R. C., Cohen, A. F., Romijn, F. P. H. T. M., Lentjes, E. G. W. M., van Rooij, J., & van Meurs, J. C. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00003-8 · Cited by 87
Self-citationBiochemical Quantification of Triamcinolone in Subconjunctival Depots
Kalina, P. H., Erie, J. C., & Rosenbaum, L. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100070041022 · Cited by 85
Treatment of Persistent Glaucoma Secondary to Periocular Corticosteroids
Akduman, L., Kolker, A. E., Black, D. L., Priore, L. V. D., & Kaplan, H. J. (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72027-6 · Cited by 66
The Ocular Uptake of Subconjunctivally Injected C14 Hydrocortisone
Wine, N. A., Gornall, A. G., & Basu, P. K. (1964) · American Journal of Ophthalmology · doi:10.1016/0002-9394(64)91214-0 · Cited by 65
Intraocular Penetration Kinetics of Prednisolone after Subconjunctival Injection in Rabbits
Tsuji, A., Tamai, I., & Sasaki, K. (2009) · Ophthalmic Research · doi:10.1159/000266253 · Cited by 48
Cited by
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
Pharmacokinetic aspects of retinal drug delivery
del Amo, E. M., Rimpelä, A.-K., Heikkinen, E., Kari, O. K., Ramsay, E., Lajunen, T., Schmitt, M., Pelkonen, L., Bhattacharya, M., Richardson, D., et al. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.001 · Cited by 693
Pharmacokinetics and Pharmacodynamics of a Sustained-Release Dexamethasone Intravitreal Implant
Chang-Lin, J.-E., Attar, M., Acheampong, A. A., Robinson, M. R., Whitcup, S. M., Kuppermann, B. D., & Welty, D. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5285 · Cited by 590
Drug delivery to the posterior segment of the eye
Thrimawithana, T. R., Young, S., Bunt, C. R., Green, C., & Alany, R. G. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2010.12.004 · Cited by 335
Locally Administered Ocular Corticosteroids: Benefits and Risks
Mcghee, C. N. J., Dean, S., & Danesh-Meyer, H. (2002) · Drug Safety · doi:10.2165/00002018-200225010-00004 · Cited by 332
Ghate, D., & Edelhauser, H. F. (2006) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.3.2.275 · Cited by 329
Transscleral drug delivery for posterior segment disease
Geroski, D. H., & Edelhauser, H. F. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00193-4 · Cited by 282
Nanomedicines for back of the eye drug delivery, gene delivery, and imaging
Kompella, U. B., Amrite, A. C., Pacha Ravi, R., & Durazo, S. A. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.04.001 · Cited by 258
Periocular routes for retinal drug delivery
Raghava, S., Hammond, M., & Kompella, U. B. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.99 · Cited by 257
Gaballa, S. A., Kompella, U. B., Elgarhy, O., Alqahtani, A. M., Pierscionek, B., Alany, R. G., & Abdelkader, H. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-020-00843-z · Cited by 255
“The subconjunctival injections were associated with some ocular side effects such as ocular pain, retinal detachment, globe perforation [173], and formation of granuloma at the injection site [162, 174].”
BackgroundIntrascleral Drug Delivery to the Eye Using Hollow Microneedles
Jiang, J., Moore, J. S., Edelhauser, H. F., & Prausnitz, M. R. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9756-3 · Cited by 208
“ocular injection (8,9) and ocular implants of gel formulations (10) and biodegradable polymers (11), and across the conjunctiva using iontophoresis (12).”
Chang-Lin, J.-E., Burke, J. A., Peng, Q., Lin, T., Orilla, W. C., Ghosn, C. R., Zhang, K.-M., Kuppermann, B. D., Robinson, M. R., Whitcup, S. M., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6387 · Cited by 197
Jamilloux, Y., Kodjikian, L., Broussolle, C., & Sève, P. (2014) · Autoimmunity Reviews · doi:10.1016/j.autrev.2014.04.001 · Cited by 193
Subconjunctival injectable dendrimer-dexamethasone gel for the treatment of corneal inflammation
Soiberman, U., Kambhampati, S. P., Wu, T., Mishra, M. K., Oh, Y., Sharma, R., Wang, J., Al Towerki, A. E., Yiu, S., Stark, W. J., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.016 · Cited by 170
“A single subconjunctival corticosteroid administration results in higher drug concentration than several topical administrations [17,24,25].”
The dexamethasone drug delivery system: Indications and evidence
London, N. J. S., Chiang, A., & Haller, J. A. (2011) · Advances in Therapy · doi:10.1007/s12325-011-0019-z · Cited by 169
Transscleral drug delivery to the posterior eye: Prospects of pharmacokinetic modeling
Ranta, V.-P., & Urtti, A. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.025 · Cited by 160
Patel, S., Garapati, C., Chowdhury, P., Gupta, H., Nesamony, J., Nauli, S., & Boddu, S. H. S. (2015) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.2014.0152 · Cited by 48
“34 No signs of irritation or redness were observed in rabbit eyes even after repeated application (2 times daily for 7 days).”
El Zaoui, I., Touchard, E., Berdugo, M., Abadie, C., Kowalczuk, L., Deloche, C., Zhao, M., Naud, M.-C., Combette, J.-M., & Behar-Cohen, F. (2015) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.2014.0019 · Cited by 31
Bonfiglio, V., Reibaldi, M., Macchi, I., Fallico, M., Pizzo, C., Patane, C., Russo, A., Longo, A., Pizzo, A., Cillino, G., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9051556 · Cited by 25
“[12–15] reported that the concentration of DEX disodium phosphate in both subretinal fluid and the vitreous of eyes affected by RRD was higher after a subconjunctival injection compared to a peribulbar injection or an oral administration [15].”
Background
Metadata
- Authors
- Weijtens, O., Feron, E. J., Schoemaker, R. C., Cohen, A. F., Lentjes, E. G. W. M., Romijn, F. P. H. T. M., & van Meurs, J. C.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1999-08
- Volume
- 128
- Issue
- 2
- Pages
- 192-197
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W1971098776
- Cited by
- 188
- References
- 12
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.