Improvement in Staging of Esophageal Cancer With the Addition of Positron Emission Tomography
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warburg, O. (1956) · Science · doi:10.1126/science.123.3191.309 · Cited by 13,425
Herskovic, A., Martz, K., Al-Sarraf, M., Leichman, L., Brindle, J., Vaitkevicius, V., Cooper, J., Byhardt, R., Davis, L., & Emami, B. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206113262403 · Cited by 2,108
Self-citationStrauss, L. G. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01367602 · Cited by 527
Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
Staging of esophageal cancer with 18F-fluorodeoxyglucose positron emission tomography.
Flanagan, F. L., Dehdashti, F., Siegel, B. A., Trask, D. D., Sundaresan, S. R., Patterson, G. A., & Cooper, J. D. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.168.2.9016218 · Cited by 312
Self-citationPET and [18F]-FDG in oncology: A clinical update
Conti, P. S., Lilien, D. L., Hawley, K., Keppler, J., Grafton, S. T., & Bading, J. R. (1996) · Nuclear Medicine and Biology · doi:10.1016/0969-8051(96)00074-1 · Cited by 259
Scott, W. J., Gobar, L. S., Terry, J. D., Dewan, N. A., & Sunderland, J. J. (1996) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70317-3 · Cited by 182
Toorongian, S. A., Mulholland, G. K., Jewett, D. M., Bachelor, M. A., & Kilbourn, M. R. (1990) · International Journal of Radiation Applications and Instrumentation Part B Nuclear Medicine and Biology · doi:10.1016/0883-2897(90)90052-3 · Cited by 148
Local threshold for segmented attenuation correction of PET imaging of the thorax
Xu, M., Luk, W. K., Cutler, P. D., & Digby, W. M. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.322944 · Cited by 122
Cited by
(2001) · PubMed · Cited by 943
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
Flamen, P., Lerut, A., Van Cutsem, E., De Wever, W., Peeters, M., Stroobants, S., Dupont, P., Bormans, G., Hiele, M., De Leyn, P., et al. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.18.3202 · Cited by 571
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Staging investigations for oesophageal cancer: a meta-analysis
van Vliet, E. P. M., Heijenbrok-Kal, M. H., Hunink, M. G. M., Kuipers, E. J., & Siersema, P. D. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604200 · Cited by 517
Chirieac, L. R., Swisher, S. G., Ajani, J. A., Komaki, R. R., Correa, A. M., Morris, J. S., Roth, J. A., Rashid, A., Hamilton, S. R., & Wu, T. (2005) · Cancer · doi:10.1002/cncr.20916 · Cited by 495
Brücher, B. L. D. M., Weber, W., Bauer, M., Fink, U., Avril, N., Stein, H. J., Werner, M., Zimmerman, F., Siewert, J. R., & Schwaiger, M. (2001) · Annals of Surgery · doi:10.1097/00000658-200103000-00002 · Cited by 389
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
van Westreenen, H. L., Westerterp, M., Bossuyt, P. M. M., Pruim, J., Sloof, G. W., van Lanschot, J. J. B., Groen, H., & Plukker, J. T. M. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.01.083 · Cited by 370
Reske, S. N., & Kotzerke, J. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100626 · Cited by 365
Bar-Shalom, R., Valdivia, A. Y., & Blaufox, M. D. (2000) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2000.7439 · Cited by 340
Downey, R. J., Akhurst, T., Ilson, D., Ginsberg, R., Bains, M. S., Gonen, M., Koong, H., Gollub, M., Minsky, B. D., Zakowski, M., et al. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.04.013 · Cited by 320
Lerut, T., Flamen, P., Ectors, N., Van Cutsem, E., Peeters, M., Hiele, M., De Wever, W., Coosemans, W., Decker, G., De Leyn, P., et al. (2000) · Annals of Surgery · doi:10.1097/00000658-200012000-00003 · Cited by 267
Kato, H., Miyazaki, T., Nakajima, M., Takita, J., Kimura, H., Faried, A., Sohda, M., Fukai, Y., Masuda, N., Fukuchi, M., et al. (2005) · Cancer · doi:10.1002/cncr.20724 · Cited by 241
“Because the evaluation of metastatic infiltration of lymph nodes is based on CT imaging measurements of lymph node size, normal-sized lymph nodes are not detected by CT.”
BackgroundResultInfluential(1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00974-1 · Cited by 235
“PET scanning for distant metastatic disease in esophageal cancer has been less frequently reported, but pilot studies suggest that between 10% and 20% of patients may have radiographically occult distant metastatic disease [8–10].”
BackgroundDetection of extrathoracic metastases by positron emission tomography in lung cancer
Weder, W., Schmid, R. A., Bruchhaus, H., Hillinger, S., von Schulthess, G. K., & Steinert, H. C. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)00675-4 · Cited by 231
Evaluation of 18F‐2‐deoxy‐2‐fluoro‐d‐glucose Positron Emission Tomography for Gastric Cancer
Mochiki, E., Kuwano, H., Katoh, H., Asao, T., Oriuchi, N., & Endo, K. (2004) · World Journal of Surgery · doi:10.1007/s00268-003-7191-5 · Cited by 221
“reported greater sensitivity with FDGPET than with CT for diagnosing involved regional lymph nodes, and they have indicated that PET may have a role in staging esophageal carcinoma [17, 27, 28].”
BackgroundClinical and translational advances in esophageal squamous cell carcinoma
(2019) · Advances in Cancer Research · doi:10.1016/bs.acr.2019.05.004 · Cited by 200
Whole-body FDG-PET imaging in the management of patients with cancer
Hustinx, R., Bénard, F., & Alavi, A. (2002) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2002.29272 · Cited by 199
Preoperative (neoadjuvant) chemoradiotherapy in oesophageal cancer
Geh, J. I., Crellin, A. M., & Glynne-Jones, R. (2001) · Journal of British Surgery · doi:10.1046/j.1365-2168.2001.01670.x · Cited by 195
Flamen, P., Lerut, A., Van Cutsem, E., Cambier, J. P., Maes, A., De Wever, W., Peeters, M., De Leyn, P., Van Raemdonck, D., & Mortelmans, L. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2000.110464 · Cited by 174
Levine, E. A., Farmer, M. R., Clark, P., Mishra, G., Ho, C., Geisinger, K. R., Melin, S. A., Lovato, J., Oaks, T., & Blackstock, A. W. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000208430.07050.61 · Cited by 165
Clinical Staging of Esophageal Carcinoma: CT, EUS, and PET
Rice, T. W. (2000) · Chest Surgery Clinics of North America · doi:10.1016/s1052-3359(25)00515-0 · Cited by 158
Metadata
- Authors
- Block, M. I., Patterson, G. A., Sundaresan, R. S., Bailey, M. S., Flanagan, F. L., Dehdashti, F., Siegel, B. A., & Cooper, J. D.
- Venue
- The Annals of Thoracic Surgery
- Publisher
- Elsevier BV
- Published
- 1997-09
- Volume
- 64
- Issue
- 3
- Pages
- 770-777
- ISSN
- 0003-4975 (ISSN-L)
- OpenAlex
- W2009626729
- Cited by
- 259
- References
- 9
- FWCI
- 10.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.