Measuring Size Distribution in Highly Heterogeneous Systems with Fluorescence Correlation Spectroscopy
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753 · cited 1×
“Fluorescence correlation spectroscopy (FCS) is one of the most powerful and sensitive techniques for measuring diffusion constants (and therefore the size) of particles in solution (Magde et al., 1972; Elson and Magde, 1974; Thompson, 1991; Eigen and Rigler, 1994; Maiti et al., 1997).”
MethodTopics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436 · cited 1×
“Fluorescence correlation spectroscopy (FCS) is one of the most powerful and sensitive techniques for measuring diffusion constants (and therefore the size) of particles in solution (Magde et al., 1972; Elson and Magde, 1974; Thompson, 1991; Eigen and Rigler, 1994; Maiti et al., 1997).”
MethodSorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956 · cited 2×
“Fluorescence correlation spectroscopy (FCS) is one of the most powerful and sensitive techniques for measuring diffusion constants (and therefore the size) of particles in solution (Magde et al., 1972; Elson and Magde, 1974; Thompson, 1991; Eigen and Rigler, 1994; Maiti et al., 1997).”
BackgroundMethodSchwille, P., Haupts, U., Maiti, S., & Webb, W. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77065-7 · Cited by 722 · cited 2×
“…small fluorescent molecules to larger substrates (Schwille et al., 1996), for investigating the spontaneous chemical kinetics of protein molecules (Haupts et al., 1998; Kummer et al., 2000), and for obtaining the intracellular viscosity of live cells (Berland et al., 1995; Schwille et al., 1999).”
BackgroundSelf-citationHaupts, U., Maiti, S., Schwille, P., & Webb, W. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13573 · Cited by 554 · cited 2×
“…small fluorescent molecules to larger substrates (Schwille et al., 1996), for investigating the spontaneous chemical kinetics of protein molecules (Haupts et al., 1998; Kummer et al., 2000), and for obtaining the intracellular viscosity of live cells (Berland et al., 1995; Schwille et al., 1999).”
BackgroundSelf-citationBerland, K. M., So, P. T., & Gratton, E. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80230-4 · Cited by 490 · cited 2×
“…small fluorescent molecules to larger substrates (Schwille et al., 1996), for investigating the spontaneous chemical kinetics of protein molecules (Haupts et al., 1998; Kummer et al., 2000), and for obtaining the intracellular viscosity of live cells (Berland et al., 1995; Schwille et al., 1999).”
BackgroundAnalyzing the Distribution of Decay Constants in Pulse-Fluorimetry Using the Maximum Entropy Method
Livesey, A. K., & Brochon, J. C. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83264-2 · Cited by 472 · cited 1×
“The algorithm has been used to obtain a distribution of fluorescence lifetimes that fits the fluorescence decay data (Livesey and Brochon, 1987; Swaminathan and Periasamy, 1996) and”
MethodStatistical accuracy in fluorescence correlation spectroscopy
Koppel, D. E. (1974) · Physical Review A · doi:10.1103/physreva.10.1938 · Cited by 450 · cited 2×
“Koppel provided such a formulation under certain assumptions (Koppel, 1974), and it has been shown that a modified version of Koppel’s analytical derivation does provide a reasonable description of the errors, but only at short enough timescales (Wohland et al.”
BackgroundFluorescence Correlation Spectroscopy: Theory and Applications
Rigler, R., & Elson, E. S. (2001) · Springer Series in Chemical Physics · doi:10.1007/978-3-642-59542-4 · Cited by 413
Maximum Entropy Image Restoration in Astronomy
Narayan, R., & Nityananda, R. (1986) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.aa.24.090186.001015 · Cited by 384 · cited 1×
“It has been shown (Narayan and Nityananda, 1986) that the Maximum Entropy Method works equally well for other definitions (Eqs.”
BackgroundFluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 317 · cited 2×
“Fluorescence correlation spectroscopy (FCS) is one of the most powerful and sensitive techniques for measuring diffusion constants (and therefore the size) of particles in solution (Magde et al., 1972; Elson and Magde, 1974; Thompson, 1991; Eigen and Rigler, 1994; Maiti et al., 1997).”
BackgroundMethodSelf-citationSchwille, P., Kummer, S., Heikal, A. A., Moerner, W. E., & Webb, W. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.1.151 · Cited by 297 · cited 2×
“…small fluorescent molecules to larger substrates (Schwille et al., 1996), for investigating the spontaneous chemical kinetics of protein molecules (Haupts et al., 1998; Kummer et al., 2000), and for obtaining the intracellular viscosity of live cells (Berland et al., 1995; Schwille et al., 1999).”
BackgroundThe Standard Deviation in Fluorescence Correlation Spectroscopy
Wohland, T., Rigler, R., & Vogel, H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76264-9 · Cited by 273 · cited 4×
“It has recently been shown that for repeated averaged autocorrelation measurements the standard error of the mean does provide a good description of the error (Wohland et al., 2001).”
BackgroundMethodInfluentialFluorescence Correlation Spectroscopy
Thompson, N. L. (2006) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47057-8_6 · Cited by 262
Single-molecule detection by two-photon-excited fluorescence
Mertz, J., Xu, C., & Webb, W. W. (1995) · Optics Letters · doi:10.1364/ol.20.002532 · Cited by 225 · cited 1×
“…¼ 1 N 1 1þ t tD 0 B@ 1 CA 1 1þ r l 2 t tD 0 B@ 1 CA 1=2 ; (2) where N is the number of particles in the volume (where the volume is defined in the sense of Mertz et al., 1995) and tD ¼ r2/4D is the time taken to diffuse through a distance r in two dimensions by a molecule with diffusion constant D.”
BackgroundPeriasamy, N., & Verkman, A. S. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77545-9 · Cited by 168
Self-citationAmyloid β-peptide polymerization studied using fluorescence correlation spectroscopy
Tjernberg, L. O., Pramanik, A., Björling, S., Thyberg, P., Thyberg, J., Nordstedt, C., Berndt, K. D., Terenius, L., & Rigler, R. (1999) · Chemistry & Biology · doi:10.1016/s1074-5521(99)80020-9 · Cited by 160 · cited 1×
“…biological systems, e.g., to follow the functionally important oligomerization of receptors on cell membranes (Olsson et al., 2001) and to examine aggregation of prionlike proteins implicated in physiological disorders (Post et al., 1998; Tjernberg et al., 1999; Sengupta et al., 2002).”
BackgroundRapid Acquisition of β-Sheet Structure in the Prion Protein Prior to Multimer Formation
Post, K., Pitschke, M., Schäfer, O., Wille, H., Appel, T. R., Kirsch, D., Mehlhorn, I., Serban, H., Prusiner, S. B., & Riesner, D. (1998) · Biological Chemistry · doi:10.1515/bchm.1998.379.11.1307 · Cited by 103 · cited 2×
“, 2001) and to examine aggregation of prionlike proteins implicated in physiological disorders (Post et al., 1998; Tjernberg et al., 1999; Sengupta et al., 2002).”
BackgroundSwaminathan, R., & Periasamy, N. (1996) · Journal of Chemical Sciences · doi:10.1007/bf02872511 · Cited by 77 · cited 1×
“The algorithm has been used to obtain a distribution of fluorescence lifetimes that fits the fluorescence decay data (Livesey and Brochon, 1987; Swaminathan and Periasamy, 1996) and”
MethodSelf-citationFluorescence Correlation Spectroscopy Detects Galanin Receptor Diversity on Insulinoma Cells
Pramanik, A., Olsson, M., Langel, Ü., Bartfai, T., & Rigler, R. W. (2001) · Biochemistry · doi:10.1021/bi010514q · Cited by 45 · cited 2×
“, to follow the functionally important oligomerization of receptors on cell membranes (Olsson et al., 2001) and to examine aggregation of prionlike proteins implicated in physiological disorders (Post et al.”
Background
Cited by
Anomalous transport in the crowded world of biological cells
Höfling, F., & Franosch, T. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/4/046602 · Cited by 1,247
Anomalous Diffusion of Proteins Due to Molecular Crowding
Banks, D. S., & Fradin, C. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.051078 · Cited by 790
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
Principles of maximum entropy and maximum caliber in statistical physics
Pressé, S., Ghosh, K., Lee, J., & Dill, K. A. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1115 · Cited by 413
Active Remodeling of Cortical Actin Regulates Spatiotemporal Organization of Cell Surface Molecules
Gowrishankar, K., Ghosh, S., Saha, S., C., R., Mayor, S., & Rao, M. (2012) · Cell · doi:10.1016/j.cell.2012.05.008 · Cited by 371
Metadata
- Authors
- Sengupta, P., Garai, K., Balaji, J., Periasamy, N., & Maiti, S.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-03
- Volume
- 84
- Issue
- 3
- Pages
- 1977-1984
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2140225232
- Cited by
- 218
- References
- 22
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.