Red Blood Cell Magnetophoresis
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The existence of unpaired electrons in the four heme groups of deoxy and methemoglobin (metHb) gives these species paramagnetic properties as contrasted to the diamagnetic character of oxyhemoglobin. Based on the measured magnetic moments of hemoglobin and its compounds, and on the relatively high hemoglobin concentration of human erythrocytes, we hypothesized that differential migration of these cells was possible if exposed to a high magnetic field. With the development of a new technology, cell tracking velocimetry, we were able to measure the migration velocity of deoxygenated and metHb-containing erythrocytes, exposed to a mean magnetic field of 1.40 T and a mean gradient of 0.131 T/mm, in a process we call cell magnetophoresis. Our results show a similar magnetophoretic mobility of 3.86 x 10(-6) mm(3) s/kg for erythrocytes with 100% deoxygenated hemoglobin and 3.66 x 10(-6) mm(3) s/kg for erythrocytes containing 100% metHb. Oxygenated erythrocytes had a magnetophoretic mobility of from -0.2 x 10(-6) mm(3) s/kg to +0.30 x 10(-6) mm(3) s/kg, indicating a significant diamagnetic component relative to the suspension medium, in agreement with previous studies on the hemoglobin magnetic susceptibility. Magnetophoresis may open up an approach to characterize and separate cells for biochemical analysis based on intrinsic and extrinsic magnetic properties of biological macromolecules.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Thus, there are about 1 × 10 9 atoms of iron in a human RBC (Chalmers et al., 2017;Zborowski et al., 2003).”
From Iron in infection and immunity (2020) · cites this paper as Zborowski et al., 2003
Citations
Cites
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159 · cited 4×
“Although the differences are minimal and do not affect our mobility measurements on deoxygenated and metHb-containing erythrocytes, our methods should allow us to address in the near future the question posed by Cerdonio (Pauling and Coryell, 1936b; Savicki et al., 1984; Cerdonio et al., 1978, 1985) about oxygenated h…”
MethodInfluentialLewis, T. J. (1982) · Physics Bulletin · doi:10.1088/0031-9112/33/8/034 · Cited by 646
Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1072 · Cited by 461 · cited 18×
“{B magnetic field intensity (in tesla (T)); m0 ¼ 4p 3 10 7 T-m/A (Spees et al., 2001; Graham, 1984).”
BackgroundMethodResultInfluential[26] Oxidative reactions of hemoglobin
Winterbourn, C. C. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)86118-f · Cited by 409 · cited 2×
“were used to calculate the percentage of metHb formed by the oxidative treatment in each sample (Winterbourn, 1990).”
MethodWeisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381 · cited 1×
“, 1984), and NMR methods (Weisskoff and Kiihne, 1992; Spees et al., 2001).”
The Magnetic Properties and Structure of the Hemochromogens and Related Substances
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.3.159 · Cited by 231
Paul, F., Roath, S., Melville, D., Warhurst, D. C., & Osisanya, J. O. S. (1981) · The Lancet · doi:10.1016/s0140-6736(81)90414-1 · Cited by 216 · cited 1×
“Erythrocytes containing hemozoin are paramagnetic, which would allow their enrichment from infected patients’ blood by magnetic means (Paul et al., 1981).”
BackgroundThe Magnetic Properties and Structure of Ferrihemoglobin (Methemoglobin) and Some of its Compounds
Coryell, C. D., Stitt, F., & Pauling, L. (1937) · Journal of the American Chemical Society · doi:10.1021/ja01283a012 · Cited by 199 · cited 9×
“Early in the 20th century, magnetic susceptibility measurements of hemoglobin and its derivatives played an important role in the study of the molecular structure of the heme group and provided an early experimental model in quantum chemistry (Pauling and Coryell, 1936a,b; Coryell et al., 1937).”
BackgroundMethodResultInfluentialDirect magnetic separation of red cells from whole blood
MELVILLE, D., PAUL, F., & ROATH, S. (1975) · Nature · doi:10.1038/255706a0 · Cited by 184 · cited 1×
“Melville and co-workers showed in the mid 1970s the equilibrium capture of erythrocytes, reduced after treatment with a sodium dithionite solution, using a ferromagnetic wire mesh that produces a high gradient magnetic field (HGMF) induced by an external field (Melville et al., 1975).”
MethodSmith, P. J., Blunt, N., Wiltshire, M., Hoy, T., Teesdale-Spittle, P., Craven, M. R., Watson, J. V., Amos, W. B., Errington, R. J., & Patterson, L. H. (2000) · Cytometry · doi:10.1002/1097-0320(20000801)40:4<280::aid-cyto4>3.0.co;2-7 · Cited by 162
Self-citationBlood Cell Biochemistry: Hematopoiesis and Gene Therapy
(1999) · Blood cell biochemistry · doi:10.1007/978-1-4615-4889-8 · Cited by 153
Fabry, M. E., & George, R. C. S. (1983) · Biochemistry · doi:10.1021/bi00286a020 · Cited by 142
Gladwin, M. T., Schechter, A. N., Shelhamer, J. H., Pannell, L. K., Conway, D. A., Hrinczenko, B. W., Nichols, J. S., Pease-Fye, M. E., Noguchi, C. T., Rodgers, G. P., et al. (1999) · Journal of Clinical Investigation · doi:10.1172/jci7637 · Cited by 131 · cited 1×
“The effects of metHb, however, would be smaller because its production by oxidative processes, especially the interaction with nitric oxide (Gladwin et al., 1999), normally leads to very low levels in the circulation.”
BackgroundSelf-citationPhysico-chemical aspects of hemozoin (malaria pigment) structure and formation
Egan, T. J. (2002) · Journal of Inorganic Biochemistry · doi:10.1016/s0162-0134(02)00372-0 · Cited by 102 · cited 1×
“During its intraerythrocytic stage, the malaria parasite ingests intracellular hemoglobin generating hemozoin, a waste product, which is an oligomeric, high spin, ferriporphyrin complex (Egan, 2002).”
BackgroundChapter 23 High-Gradient Magnetic Cell Sorting
Radbruch, A., Mechtold, B., Thiel, A., Miltenyi, S., & Pflüger, E. (1994) · Methods in cell biology · doi:10.1016/s0091-679x(08)61086-9 · Cited by 83 · cited 1×
“These columns were the precursors of the immunomagnetic cell separation columns commercially available today in which cell selection is done with the use of monoclonal antibodies linked to ferromagnetic nanoparticles (Roath et al., 1992, 1994; Radbruch et al., 1994; Svoboda, 2000).”
BackgroundHigh gradient magnetic separation of erythrocytes
Owen, C. S. (1978) · Biophysical Journal · doi:10.1016/s0006-3495(78)85482-4 · Cited by 80 · cited 1×
“Later, Owen showed that equilibrium cell capture was also possible using metHb-containing erythrocytes (Owen, 1978).”
BackgroundFlow Rate Optimization for the Quadrupole Magnetic Cell Sorter
Williams, P. S., Zborowski, M., & Chalmers, J. J. (1999) · Analytical Chemistry · doi:10.1021/ac990284+ · Cited by 75
Self-citationMagnetophoretic mobilities correlate to antibody binding capacities
McCloskey, K. E., Chalmers, J. J., & Zborowski, M. (2000) · Cytometry · doi:10.1002/1097-0320(20000801)40:4<307::aid-cyto6>3.0.co;2-h · Cited by 73 · cited 2×
“Particularly interesting were the experiments in which we measured MM relative to cell surface antigen expression in specific cell types, and its effect on immunomagnetic cell labeling efficiency (McCloskey et al., 2000, 2001).”
BackgroundSelf-citationHigh Gradient Magnetic Cell Sorting
Miltenyi, S., & Schmitz, J. (2000) · Springer eBooks · doi:10.1007/978-3-662-04129-1_20 · Cited by 64
Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin
CERDONIO, M., Congiu‐Castellano, A., Calabrese, L., Morante, S., Pispisa, B., & Vitale, S. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.10.4916 · Cited by 58 · cited 2×
“…measurements on deoxygenated and metHb-containing erythrocytes, our methods should allow us to address in the near future the question posed by Cerdonio (Pauling and Coryell, 1936b; Savicki et al., 1984; Cerdonio et al., 1978, 1985) about oxygenated hemoglobin’s possible paramagnetic contribution.”
MethodMagnetic susceptibility of oxy- and carbonmonoxyhemoglobins.
Savicki, J. P., Lang, G., & Ikeda‐Saito, M. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.17.5417 · Cited by 57 · cited 16×
“Although the differences are minimal and do not affect our mobility measurements on deoxygenated and metHb-containing erythrocytes, our methods should allow us to address in the near future the question posed by Cerdonio (Pauling and Coryell, 1936b; Savicki et al., 1984; Cerdonio et al., 1978, 1985) about oxygenated h…”
BackgroundMethodResultInfluentialSEPARATIONS BASED ON MAGNETOPHORETIC MOBILITY
Zborowski, M., Moore, L. R., Williams, P. S., & Chalmers, J. J. (2002) · Separation Science and Technology · doi:10.1081/ss-120014809 · Cited by 53 · cited 3×
“In general, cell mobility is defined as directly proportional to the particlefield interaction parameter, and inversely proportional to the cell friction coefficient (Zborowski et al., 2002).”
BackgroundMethodSelf-citationThe use of magnetite-doped polymeric microspheres in calibrating cell tracking velocimetry
Moore, L. R., Zborowski, M., Nakamura, M., McCloskey, K. E., Gura, S., Zuberi, M., Margel, S., & Chalmers, J. J. (2000) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(00)00085-3 · Cited by 53 · cited 12×
“The CTV channel was flushed with ;60 ml of carrier buffer before each experiment.”
BackgroundMethodResultSelf-citationStatistical investigation of errors in particle image velocimetry
GUEZENNEC, Y. G., & Kiritsis, N. (1990) · Experiments in Fluids · doi:10.1007/bf00215022 · Cited by 49
Nakamura, M., Zborowski, M., Lasky, L. C., Margel, S., & Chalmers, J. J. (2001) · Experiments in Fluids · doi:10.1007/s003480000211 · Cited by 46 · cited 12×
“The CTV channel was flushed with ;60 ml of carrier buffer before each experiment.”
BackgroundMethodResultSelf-citationReexamination of the evidence for paramagnetism in oxy- and carbonmonoxyhemoglobins.
CERDONIO, M., Morante, S., Torresani, D., Vitale, S., DeYoung, A., & Noble, R. W. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.1.102 · Cited by 45 · cited 3×
“…measurements on deoxygenated and metHb-containing erythrocytes, our methods should allow us to address in the near future the question posed by Cerdonio (Pauling and Coryell, 1936b; Savicki et al., 1984; Cerdonio et al., 1978, 1985) about oxygenated hemoglobin’s possible paramagnetic contribution.”
BackgroundMethodRed cell age effects on metabolism and oxygen affinity in humans
Schmidt, W., Boning, D. G., & Braumann, K.-M. (1987) · Respiration Physiology · doi:10.1016/s0034-5687(87)80007-5 · Cited by 41 · cited 1×
“In this case, however, the likely source is slight difference in oxygen saturation between individual cells due to physiological variations in oxygen affinity, normally found during cell aging (Samaja et al., 1990; Schmidt et al., 1987).”
BackgroundDiamagnetic capture in single wire HGMS
Friedlaender, F., Takayasu, M., Nakano, T., & McNeese, W. (1979) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1979.1060451 · Cited by 38 · cited 1×
“Early measurements of red blood cell (RBC) MM relied on the HGMF geometry (Friedlaender et al., 1979; Plyavin and Blum, 1983).”
MethodSeparation of red blood cells by magnetic means
Svoboda, J. (2000) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)00479-0 · Cited by 34 · cited 1×
“These columns were the precursors of the immunomagnetic cell separation columns commercially available today in which cell selection is done with the use of monoclonal antibodies linked to ferromagnetic nanoparticles (Roath et al., 1992, 1994; Radbruch et al., 1994; Svoboda, 2000).”
BackgroundMagnetophoresis: I. detection of magnetically labeled cells
Winoto‐Morbach, S., Tchikov, V., & Müller-Ruchholtz, W. (1994) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.1860080610 · Cited by 31
Erythrocyte Membrane Changes during Aging in Vivo
Bartosz, G. (1990) · Blood cell biochemistry · doi:10.1007/978-1-4757-9528-8_3 · Cited by 27 · cited 1×
“The cellular contents of enzymes involved in antioxidant protection, including metHb reductase, is higher in young erythrocytes (Bartosz, 1990).”
BackgroundA flow cytometry technique for measuring chromosome-mediated gene transfer
Vanderbyl, S. L., MacDonald, N., & de Jong, G. (2001) · Cytometry · doi:10.1002/1097-0320(20010601)44:2<126::aid-cyto1091>3.0.co;2-n · Cited by 24
Self-citationComparison between immunofluorescence and immunomagnetic techniques of cytometry
Tchikov, V., Schütze, S., & Krönke, M. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00567-8 · Cited by 23 · cited 1×
“2003 by the Biophysical Society 0006-3495/03/04/2638/08 $2.00 calculating the mobile cell fraction, giving no information about the mobility of individual cells (Winoto-Morbach et al., 1994; Tchikov et al., 1999).”
MethodInfluentialHuman red cell age, oxygen affinity and oxygen transport
Samaja, M., Rovida, E., Motterlini, R., Tarantola, M., Rubinacci, A., & diPrampero, P. E. (1990) · Respiration Physiology · doi:10.1016/0034-5687(90)90061-3 · Cited by 20 · cited 1×
“In this case, however, the likely source is slight difference in oxygen saturation between individual cells due to physiological variations in oxygen affinity, normally found during cell aging (Samaja et al., 1990; Schmidt et al., 1987).”
BackgroundMeasurement of CD2 expression levels of IFN-?-treated fibrosarcomas using cell tracking velocimetry
McCloskey, K. E., Zborowski, M., & Chalmers, J. J. (2001) · Cytometry · doi:10.1002/1097-0320(20010601)44:2<137::aid-cyto1093>3.0.co;2-d · Cited by 16
Self-citationRoath, S., Thomas, T. E., Jh, W., Lansdorp, P., Rj, S., & Aj, R. (1994) · PubMed · Cited by 10
COMPARISON OF VOLUME AND SURFACE MECHANISMS FOR MAGNETIC FILTRATION OF BLOOD CELLS
Graham, M. D. (1984) · Le Journal de Physique Colloques · doi:10.1051/jphyscol:19841159 · Cited by 9 · cited 7×
“{B magnetic field intensity (in tesla (T)); m0 ¼ 4p 3 10 7 T-m/A (Spees et al., 2001; Graham, 1984).”
BackgroundMethodInfluentialPositive selection of cell subpopulations using a high gradient magnetic field system.
Roath, S., Rj, S., Aj, R., & Jh, W. (1992) · PubMed · Cited by 1
Research works printed but not linked: 2
- Ostera, G. 2001. Differential oxidative susceptibility of fetal and adult erythroid cells as a marker for cell separation. Ph.D. thesis. Georgetown University, Washington.
- Plyavin, 1983, Magnetic parameters of blood cells and high gradient paramagnetic and diamagnetic phoresis, Magnetohydrodynamics, 19, 349
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
“Zborowski et al. measured the magnetophoretic mobility of erythrocytes containing these species (under a magnetic field of 1.4 T, mean gradient of 0.131 T/mm) and made a case for separation based on these properties when label-based separation is limited by shared surface antigens [ 79 ].”
BackgroundInfluentialContinuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
“demonstrated magnetophoresis of red blood cells, as well as human lymphocytes labeled with iron-rich protein ferritin [119, 121].”
Background
Metadata
- Authors
- Zborowski, M., Ostera, G. R., Moore, L. R., Milliron, S., Chalmers, J. J., & Schechter, A. N.
- Affiliations
- Cleveland Clinic (US)
- National Institutes of Health (US)
- The Ohio State University (US)
- Corresponding author
- Zborowski, Maciej
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 84
- Issue
- 4
- Pages
- 2638-2645
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1302830
- OpenAlex
- W2055459109
- Semantic Scholar
- ac84d1d1582750c9f8da2a72a80ae705ee302f70
- Cited by
- 260
- References
- 36
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 7 · 2023: 14 · 2022: 12 · 2021: 8 · 2020: 10 · 2019: 11 · 2018: 14 · 2017: 13 · 2016: 16 · 2015: 6 · 2014: 12 · 2013: 18 · 2012: 19
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 3759 d)
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Cancer Institute (R33CA081662, R01CA062349)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geomagnetism and Paleomagnetism Studies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- erythrocytes, methemoglobin, deoxyhemoglobin, paramagnetism, magnetophoretic mobility, magnetic field gradient, cell isolation
- MeSH terms
- Cell Movement, Cell Separation, Electromagnetic Fields, Erythrocytes, Hemoglobins, Humans, Magnetics, Oxyhemoglobins, Rheology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.