The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
MRI susceptometry: Image‐based measurement of absolute susceptibility of MR contrast agents and human blood
Abstract
We present a novel NMR imaging technique that allows absolute determination of the magnetic susceptibility constant, χ, of a solution. By comparing the phase difference of MR images produced with an instant (echo planar) “offset” spin‐echo sequence, we obtain a direct measure of the magnetic field perturbations caused by the solution. We demonstrate this method with Gd(DTPA), Dy(DTPA), human red blood cells, and superparamagnetic iron oxide particles. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Chu, K. ‐. C., Xu, Y., Balschi, J. A., & Springer, C. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130207 · Cited by 373
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Self-citationFabry, M. E., & George, R. C. S. (1983) · Biochemistry · doi:10.1021/bi00286a020 · Cited by 129
Hardy, P., & Henkelman, R. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170207 · Cited by 60
Cited by
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Self-citationSusceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Metadata
- Authors
- Weisskoff, R. M., & Kiihne, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-04
- Volume
- 24
- Issue
- 2
- Pages
- 375-383
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1964906439
- Cited by
- 381
- References
- 12
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MRI susceptometry: Image‐based measurement of absolute susceptibility of MR contrast agents and human blood. https://app.cochat.ai/papers/10.1002/mrm.1910240219
- The paper
- Weisskoff, R. M., & Kiihne, S. (1992). MRI susceptometry: Image‐based measurement of absolute susceptibility of MR contrast agents and human blood. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910240219
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.