Red Blood Cell Magnetophoresis
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The existence of unpaired electrons in the four heme groups of deoxy and methemoglobin (metHb) gives these species paramagnetic properties as contrasted to the diamagnetic character of oxyhemoglobin. Based on the measured magnetic moments of hemoglobin and its compounds, and on the relatively high hemoglobin concentration of human erythrocytes, we hypothesized that differential migration of these cells was possible if exposed to a high magnetic field. With the development of a new technology, cell tracking velocimetry, we were able to measure the migration velocity of deoxygenated and metHb-containing erythrocytes, exposed to a mean magnetic field of 1.40 T and a mean gradient of 0.131 T/mm, in a process we call cell magnetophoresis. Our results show a similar magnetophoretic mobility of 3.86 x 10(-6) mm(3) s/kg for erythrocytes with 100% deoxygenated hemoglobin and 3.66 x 10(-6) mm(3) s/kg for erythrocytes containing 100% metHb. Oxygenated erythrocytes had a magnetophoretic mobility of from -0.2 x 10(-6) mm(3) s/kg to +0.30 x 10(-6) mm(3) s/kg, indicating a significant diamagnetic component relative to the suspension medium, in agreement with previous studies on the hemoglobin magnetic susceptibility. Magnetophoresis may open up an approach to characterize and separate cells for biochemical analysis based on intrinsic and extrinsic magnetic properties of biological macromolecules.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Thus, there are about 1 × 10 9 atoms of iron in a human RBC (Chalmers et al., 2017;Zborowski et al., 2003).”
From Iron in infection and immunity (2020) · cites this paper as Zborowski et al., 2003
Citations
Cites
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159 · cited 4×
“Although the differences are minimal and do not affect our mobility measurements on deoxygenated and metHb-containing erythrocytes, our methods should allow us to address in the near future the question posed by Cerdonio (Pauling and Coryell, 1936b; Savicki et al., 1984; Cerdonio et al., 1978, 1985) about oxygenated h…”
MethodInfluentialLewis, T. J. (1982) · Physics Bulletin · doi:10.1088/0031-9112/33/8/034 · Cited by 646
Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1072 · Cited by 461 · cited 18×
“{B magnetic field intensity (in tesla (T)); m0 ¼ 4p 3 10 7 T-m/A (Spees et al., 2001; Graham, 1984).”
BackgroundMethodResultInfluential[26] Oxidative reactions of hemoglobin
Winterbourn, C. C. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)86118-f · Cited by 409 · cited 2×
“were used to calculate the percentage of metHb formed by the oxidative treatment in each sample (Winterbourn, 1990).”
MethodWeisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381 · cited 1×
“, 1984), and NMR methods (Weisskoff and Kiihne, 1992; Spees et al., 2001).”
The Magnetic Properties and Structure of the Hemochromogens and Related Substances
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.3.159 · Cited by 231
Paul, F., Roath, S., Melville, D., Warhurst, D. C., & Osisanya, J. O. S. (1981) · The Lancet · doi:10.1016/s0140-6736(81)90414-1 · Cited by 216 · cited 1×
“Erythrocytes containing hemozoin are paramagnetic, which would allow their enrichment from infected patients’ blood by magnetic means (Paul et al., 1981).”
BackgroundThe Magnetic Properties and Structure of Ferrihemoglobin (Methemoglobin) and Some of its Compounds
Coryell, C. D., Stitt, F., & Pauling, L. (1937) · Journal of the American Chemical Society · doi:10.1021/ja01283a012 · Cited by 199 · cited 9×
“Early in the 20th century, magnetic susceptibility measurements of hemoglobin and its derivatives played an important role in the study of the molecular structure of the heme group and provided an early experimental model in quantum chemistry (Pauling and Coryell, 1936a,b; Coryell et al., 1937).”
BackgroundMethodResultInfluentialDirect magnetic separation of red cells from whole blood
MELVILLE, D., PAUL, F., & ROATH, S. (1975) · Nature · doi:10.1038/255706a0 · Cited by 184 · cited 1×
“Melville and co-workers showed in the mid 1970s the equilibrium capture of erythrocytes, reduced after treatment with a sodium dithionite solution, using a ferromagnetic wire mesh that produces a high gradient magnetic field (HGMF) induced by an external field (Melville et al., 1975).”
MethodSmith, P. J., Blunt, N., Wiltshire, M., Hoy, T., Teesdale-Spittle, P., Craven, M. R., Watson, J. V., Amos, W. B., Errington, R. J., & Patterson, L. H. (2000) · Cytometry · doi:10.1002/1097-0320(20000801)40:4<280::aid-cyto4>3.0.co;2-7 · Cited by 162
Self-citation
Research works printed but not linked: 2
- Ostera, G. 2001. Differential oxidative susceptibility of fetal and adult erythroid cells as a marker for cell separation. Ph.D. thesis. Georgetown University, Washington.
- Plyavin, 1983, Magnetic parameters of blood cells and high gradient paramagnetic and diamagnetic phoresis, Magnetohydrodynamics, 19, 349
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
“Zborowski et al. measured the magnetophoretic mobility of erythrocytes containing these species (under a magnetic field of 1.4 T, mean gradient of 0.131 T/mm) and made a case for separation based on these properties when label-based separation is limited by shared surface antigens [ 79 ].”
BackgroundInfluentialContinuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
“demonstrated magnetophoresis of red blood cells, as well as human lymphocytes labeled with iron-rich protein ferritin [119, 121].”
BackgroundToner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
“Analytical magnetapheresis has been demonstrated in experimental settings involving microscopic features (51, 52).”
BackgroundIron in infection and immunity
Nairz, M., & Weiss, G. (2020) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2020.100864 · Cited by 359
Magnetic separations: From steel plants to biotechnology
Yavuz, C. T., Prakash, A., Mayo, J. T., & Colvin, V. L. (2009) · Chemical Engineering Science · doi:10.1016/j.ces.2008.11.018 · Cited by 343
“…cells, i.e. neural progenitor cells (Lewin et al., 2000), red blood cells (Haukanes and Kvam, 1993; Seesod et al., 1997; Takayasu et al., 2000; Zborowski et al., 2003), tumor cells (Wang et al., 2004), malarial parasites (Paul et al., 1981), baker's yeast (Azevedo et al., 2003), can be…”
BackgroundFundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
“The same research group has illustrated that RBC removal, without magnetic tags, is possible using QMS (Zborowski et al 2003, Jin et al 2012, Moore et al 2013, 2014).”
BackgroundInfluentialContinuous separation of blood cells in spiral microfluidic devices
Nivedita, N., & Papautsky, I. (2013) · Biomicrofluidics · doi:10.1063/1.4819275 · Cited by 245
Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations
Han, K.-H., & Frazier, A. B. (2006) · Lab Chip · doi:10.1039/b514539b · Cited by 205
Yang, L., Lang, J. C., Balasubramanian, P., Jatana, K. R., Schuller, D., Agrawal, A., Zborowski, M., & Chalmers, J. J. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22066 · Cited by 200
Self-citationThe intersection of flow cytometry with microfluidics and microfabrication
Piyasena, M. E., & Graves, S. W. (2014) · Lab Chip · doi:10.1039/c3lc51152a · Cited by 189
Antfolk, M., & Laurell, T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.017 · Cited by 184
Magnetophoretic separation of blood cells at the microscale
Furlani, E. P. (2007) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/40/5/001 · Cited by 166
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“Using a constant magnetic field to separate cells based on the inherent magnetism of each cell in a population was demonstrated by magnetophoresis of red blood cells and labeled human lymphocytes [142,143].”
BackgroundCell manipulation in microfluidics
Yun, H., Kim, K.-S., & Lee, W. G. (2013) · Biofabrication · doi:10.1088/1758-5082/5/2/022001 · Cited by 169
Unified View of Magnetic Nanoparticle Separation under Magnetophoresis
Leong, S. S., Ahmad, Z. A., Low, S. C., Camacho, J., Faraudo, J., & Lim, J. (2020) · Langmuir · doi:10.1021/acs.langmuir.0c00839 · Cited by 147
Cell Culture on MEMS Platforms: A Review
Ni, M., Tong, W. H., Choudhury, D., Rahim, N. A. A., Iliescu, C., & Yu, H. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10125411 · Cited by 162
“Other microfluidic cell sorting technologies developed include devices for high content cell analysis and sorting, impedance spectroscopy for cell sorting, magnetic cell sorting (MACS) [171], and selective cell lysis to biochemically separate the blood cell types [172,173].”
MethodLab-on-Chip for Exosomes and Microvesicles Detection and Characterization
Chiriacò, M. S., Bianco, M., Nigro, A., Primiceri, E., Ferrara, F., Romano, A., Quattrini, A., Furlan, R., Arima, V., & Maruccio, G. (2018) · Sensors · doi:10.3390/s18103175 · Cited by 130
“The possibility to carry out separation of red blood cells without a magnetic label but on the basis of intrinsic magnetic properties due to iron in the haemoglobin was also reported (as well as for some strains of Bacillus spores due to manganese content) [173,174].”
BackgroundMicrosystems for isolation and electrophysiological analysis of breast cancer cells from blood
Han, K.-H., Han, A., & Frazier, A. B. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.024 · Cited by 119
Basic Principles and Recent Advances in Magnetic Cell Separation
Frénéa‐Robin, M., & Marchalot, J. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010011 · Cited by 133
Jain, V., Abdulmalik, O., Propert, K. J., & Wehrli, F. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23282 · Cited by 113
“(22) on RBC magnetophoretic motilities yielded a value of 0.”
BackgroundMagnetic Biotransport: Analysis and Applications
Furlani, E. P. (2010) · Materials · doi:10.3390/ma3042412 · Cited by 130
Hosseini, E., Loghmani, G. B., Heydari, M., & Rashidi, M. M. (2017) · The European Physical Journal Plus · doi:10.1140/epjp/i2017-11598-1 · Cited by 114
Continuous-flow ferrohydrodynamic sorting of particles and cells in microfluidic devices
Zhu, T., Cheng, R., Lee, S. A., Rajaraman, E., Eiteman, M. A., Querec, T. D., Unger, E. R., & Mao, L. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1004-9 · Cited by 115
Magnetic Force-Based Microfluidic Techniques for Cellular and Tissue Bioengineering
Yaman, S., Anıl-İnevi, M., Özçivici, E., & Tekin, H. C. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00192 · Cited by 120
“In addition, intrinsic magnetic properties of erythrocytes with iron-containing hemoglobin have been exploited in positive magnetophoresis for cell separation (Zborowski et al., 2003).”
BackgroundCima, I., Wen Yee, C., Iliescu, F. S., Min Phyo, W., Hon Lim, K., Iliescu, C., & Han Tan, M. (2013) · Biomicrofluidics · doi:10.1063/1.4780062 · Cited by 106
Magnetic Separation of Malaria-Infected Red Blood Cells in Various Developmental Stages
Nam, J., Huang, H., Lim, H., Lim, C., & Shin, S. (2013) · Analytical Chemistry · doi:10.1021/ac4012057 · Cited by 104
Hemoglobin degradation in malaria‐infected erythrocytes determined from live cell magnetophoresis
Moore, L. R., Fujioka, H., Williams, P. S., Chalmers, J. J., Grimberg, B., Zimmerman, P. A., & Zborowski, M. (2006) · The FASEB Journal · doi:10.1096/fj.05-5122fje · Cited by 103
“In order to produce an observable displacement on a large number of erythrocytes randomly distributed within a microscope field, an open-gradient, spatially independent [isodynamic (20, 29)] field configuration was used, as illustrated in Fig.”
BackgroundMethodInfluentialSelf-citationLeong, S. S., Yeap, S. P., & Lim, J. (2016) · Interface Focus · doi:10.1098/rsfs.2016.0048 · Cited by 107
Lateral-driven continuous magnetophoretic separation of blood cells
Jung, J.-H., & Han, K.-H. (2008) · Applied Physics Letters · doi:10.1063/1.3036898 · Cited by 100
Zhu, T., Lichlyter, D. J., Haidekker, M. A., & Mao, L. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0754-5 · Cited by 96
“…particles and cells (Pamme and Manz 2004; Pamme 2006; Pamme and Wilhelm 2006) except in the cases of manipulation of red blood cells and magnetotactic bacteria, both of which are paramagnetic by themselves (Schuler and Frankel 1999; Zborowski et al. 2003; Han and Frazier 2004; Lee et al. 2004).”
BackgroundUrine biopsy technologies: Cancer and beyond
Chen, C. K., Liao, J., Li, M. S., & Khoo, B. L. (2020) · Theranostics · doi:10.7150/thno.44634 · Cited by 100
“Contrary to acoustophoresis, magnetophoresis is a label-based approach of which specific targets labelled by antibody-coated magnetic beads will be immobilized or concentrated on designed outlets under the external magnetic field to achieve the isolation of specific labelled targets [111].”
BackgroundXu, S., Okano, H., Tomita, N., & Ikada, Y. (2010) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2011/620984 · Cited by 93
“Other reports indicate that an SMF of strong intensity higher than a few Tesla has bioeffects [8, 9, 53–62].”
BackgroundKasetsirikul, S., Buranapong, J., Srituravanich, W., Kaewthamasorn, M., & Pimpin, A. (2016) · Malaria Journal · doi:10.1186/s12936-016-1400-9 · Cited by 94
“5 [80, 86].”
Isolating plasma from blood using a dielectrophoresis-active hydrophoretic device
Yan, S., Zhang, J., Alıcı, G., Du, H., Zhu, Y., & Li, W. (2014) · Lab on a Chip · doi:10.1039/c4lc00343h · Cited by 82
Dielectrophoretic characterization of erythrocytes: Positive ABO blood types
Srivastava, S. K., Daggolu, P. R., Burgess, S. C., & Minerick, A. R. (2008) · Electrophoresis · doi:10.1002/elps.200800166 · Cited by 91
Quantitative intracellular magnetic nanoparticle uptake measured by live cell magnetophoresis
Jing, Y., Mal, N., Williams, P. S., Mayorga, M. E., Penn, M. S., Chalmers, J. J., & Zborowski, M. (2008) · The FASEB Journal · doi:10.1096/fj.07-105544 · Cited by 73
“We have used this method to measure changes in magnetic susceptibility of single erythrocytes (25, 32), to characterize the cell binding of antibodies conjugated to magnetic nanoparticles (33, 34), and to measure magnetic susceptibility of nanoparticles used for immunomagnetic cell separation (27) and magnetic suscept…”
MethodSelf-citationHydrophoretic high-throughput selection of platelets in physiological shear-stress range
Choi, S., Ku, T., Song, S., Choi, C., & Park, J. (2010) · Lab on a Chip · doi:10.1039/c0lc00148a · Cited by 72
A glass microfluidic chip for continuous blood cell sorting by a magnetic gradient without labeling
Qu, B.-Y., Wu, Z., Fang, F., Bai, Z., Yang, D., & Xu, S.-K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2382-4 · Cited by 72
Exploring linearity of deep neural network trained QSM: QSMnet+
Jung, W., Yoon, J., Ji, S., Choi, J. Y., Kim, J. M., Nam, Y., Kim, E. Y., & Lee, J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116619 · Cited by 84
“ution of the training dataset sufficiently covered the susceptibility value of the fully deoxygenated blood, which was approximately 1.4 ppm (see Discussion) (Chang et al., 2016; Haacke et al., 1997; Zborowski et al., 2003). The four different QSMnet+ networks were labeled as QSMnetλ=1 + , QSMnet λ=2 + , QSMnet λ=3 +…”
InfluentialBég, O. A., Bhargava, R. R., Rawat, S., Halim, K., & Takhar, H. S. (2007) · Meccanica · doi:10.1007/s11012-007-9102-6 · Cited by 67
Pulsatile magneto-biofluid flow and mass transfer in a non-Darcian porous medium channel
Bhargava, R. R., Rawat, S., Takhar, H. S., & Bég, O. A. (2007) · Meccanica · doi:10.1007/s11012-007-9052-z · Cited by 65
Zhang, H., Moore, L. R., Zborowski, M., Williams, P. S., Margel, S., & Chalmers, J. J. (2005) · The Analyst · doi:10.1039/b412723d · Cited by 62
Self-citationMagnetic susceptibility of iron in malaria-infected red blood cells
Hackett, S. L., Hamzah, J., Davis, T. M. E., & Pierre, T. G. S. (2008) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2008.11.001 · Cited by 60
“15 agreement with recent literature values [7, 8, 34].”
BackgroundMethodInfluentialMagnetophoresis of Nonmagnetic Particles in Ferrofluids
Gao, Y., Jian, Y. C., Zhang, L. F., & Huang, J. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp0705673 · Cited by 70
Micropatterning of Cells Using Modulated Magnetic Fields
Kimura, T., Sato, Y., Kimura, F., Iwasaka, M., & Ueno, S. (2004) · Langmuir · doi:10.1021/la047517z · Cited by 60
Häfeli, U. O., Lobedann, M. A., Steingroewer, J., Moore, L. R., & Riffle, J. S. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.02.001 · Cited by 57
Self-citationLangham, M. C., Magland, J. F., Epstein, C. L., Floyd, T. F., & Wehrli, F. W. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21981 · Cited by 54
Diamagnetic capture mode magnetophoretic microseparator for blood cells
Han, K.-H., & Frazier, A. B. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859097 · Cited by 54
Recent Advances in Continuous-Flow Particle Manipulations Using Magnetic Fluids
Xuan, X. S. (2019) · Micromachines · doi:10.3390/mi10110744 · Cited by 59
Magnetophoresis of iron oxide nanoparticles at low field gradient: The role of shape anisotropy
Lim, J., Yeap, S. P., Leow, C. H., Toh, P. Y., & Low, S. C. (2014) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.01.044 · Cited by 51
Hemolysis as Expression of Nanoparticles-Induced Cytotoxicity in Red Blood Cells
Mocan, T. (2013) · Cited by 59
Design of microfluidic channels for magnetic separation of malaria-infected red blood cells
Wu, W., Martin, A. B., Gandini, A., Aubry, N., Massoudi, M., & Antaki, J. F. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1707-4 · Cited by 50
“It has been known for many decades that the malaria-infected, parasitized RBCs (pRBCs) exhibit paramagnetic properties; therefore, it is possible to separate and remove the pRBCs by applying a force via a high magnetic field gradient (Paul et al. 1981; Zborowski et al. 2003; Moore et al. 2006; Hackett et al. 2009).”
On magnetophoretic separation of blood cells using Halbach array of magnets
Shiriny, A., & Bayareh, M. (2020) · Meccanica · doi:10.1007/s11012-020-01225-y · Cited by 52
Das, S., Chakraborty, S. K., & Mitra, S. K. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1001-z · Cited by 47
Immunology on chip: Promises and opportunities
Baratchi, S., Khoshmanesh, K., Sacristán, C., Depoil, D., Włodkowic, D., McIntyre, P., & Mitchell, A. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.008 · Cited by 51
Zhang, H., Williams, P. S., Zborowski, M., & Chalmers, J. J. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.21024 · Cited by 47
“While it is true for most types of cells suspended in buffer (mainly phosphate buffered saline (PBS)), it has been reported that red blood cells showdifferent intrinsicmagnetic properties as a result of the oxygenization state of hemoglobin (Zborowski et al., 2003).”
BackgroundSelf-citationThree-dimensional and analytical modeling of microfluidic particle transport in magnetic fluids
Cheng, R., Zhu, T., & Mao, L. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1280-z · Cited by 46
Simultaneous Separation and Washing of Nonmagnetic Particles in an Inertial Ferrofluid/Water Coflow
Chen, Q., Li, D., Lin, J., Wang, M., & Xuan, X. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01608 · Cited by 46
Advances in Microfluidics for Single Red Blood Cell Analysis
Grigorev, G. V., Lebedev, A., Wang, X., Qian, X., Maksimov, G. V., & Lin, L. (2023) · Biosensors · doi:10.3390/bios13010117 · Cited by 54
Sharma, M. K., Bansal, K., & Bansal, S. (2012) · Korea-Australia Rheology Journal · doi:10.1007/s13367-012-0022-1 · Cited by 49
Adhesive-based liquid metal radio-frequency microcoil for magnetic resonance relaxometry measurement
Kong, T. F., Peng, W. K., Luong, T. D., Nguyen, N., & Han, J. (2012) · Lab on a Chip · doi:10.1039/c1lc20853e · Cited by 46
Chalmers, J. J., Xiong, Y., Jin, X., Shao, M., Tong, X., Farag, S. S., & Zborowski, M. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22635 · Cited by 43
“labels, or intrinsic to the cell itself (Melnik et al., 2007; Zborowski et al., 2003) to be quantified.”
BackgroundMethodSelf-citationAndhariya, N., Chudasama, B., Patel, R., Upadhyay, R. V., & Mehta, R. V. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.04.018 · Cited by 42
Six-stage cascade paramagnetic mode magnetophoretic separation system for human blood samples
Jung, Y., Choi, Y., Han, K.-H., & Frazier, A. B. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9416-3 · Cited by 41
In Situ 3D Label-Free Contactless Bioprinting of Cells through Diamagnetophoresis
Fattah, A. R. A., Meleca, E., Mishriki, S., Lelic, A., Geng, F., Sahu, R. P., Ghosh, S., & Puri, I. K. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00614 · Cited by 43
Klein, A. N., & Schankin, C. J. (2021) · Headache The Journal of Head and Face Pain · doi:10.1111/head.14213 · Cited by 47
Magnetophoresis: Fundamentals and Applications
Zborowski, M., & Chalmers, J. J. (2015) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w8236 · Cited by 41
Self-citationBég, O. A., Bég, T. A., Bhargava, R. R., RAWAT, S., & Tripathi, D. (2012) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519412500819 · Cited by 40
Leukocyte depletion for safe blood transfusion
Singh, S., & Kumar, A. (2009) · Biotechnology Journal · doi:10.1002/biot.200800182 · Cited by 40
Magnetophoresis of diamagnetic microparticles in a weak magnetic field
Zhu, G., Hejiazan, M., Huang, X., & Nguyen, N. (2014) · Lab on a Chip · doi:10.1039/c4lc00885e · Cited by 38
Micro/Nanosystems for Magnetic Targeted Delivery of Bioagents
Garello, F., Svenskaya, Y. I., Parakhonskiy, B. V., & Filippi, M. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14061132 · Cited by 40
Moore, L. R., Milliron, S., Williams, P. S., Chalmers, J. J., Margel, S., & Zborowski, M. (2004) · Analytical Chemistry · doi:10.1021/ac049910f · Cited by 35
Self-citationFabricated Micro‐Nano Devices for In vivo and In vitro Biomedical Applications
Barkam, S., Saraf, S., & Seal, S. (2013) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1236 · Cited by 40
Current and emerging techniques of fetal cell separation from maternal blood
Kavanagh, D. M., Kersaudy-Kerhoas, M., Dhariwal, R. S., & Desmulliez, M. P. Y. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.05.007 · Cited by 38
Hoque, M. M., Alam, M. M., Ferdows, M., & Bég, O. A. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913493844 · Cited by 33
Strategy for selection of methods for separation of bioparticles from particle mixtures
van Hee, P., Hoeben, M. A., van der Lans, R. G. J. M., & van der Wielen, L. A. M. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20885 · Cited by 33
“Even though this force can possibly exceed the centrifugal force, it has been applied in biotechnology mostly on a small scale for the concentration and separation of cells (Comella et al., 2001; Cullison and Jaykus, 2002; McCloskey et al., 2003;Melville et al., 1975; Owen, 1978; Radbruch et al., 1994; Zborowski et al…”
BackgroundChen, Q., Li, D., Malekanfard, A., Cao, Q., Lin, J., Wang, M., Han, X., & Xuan, X. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01813 · Cited by 32
Jin, X., Zhao, Y., Richardson, A., Moore, L. R., Williams, P. S., Zborowski, M., & Chalmers, J. J. (2008) · The Analyst · doi:10.1039/b802113a · Cited by 31
Self-citationMultifunctional manipulation of red blood cells using optical tweezers
Xie, Y., & Liu, X. (2021) · Journal of Biophotonics · doi:10.1002/jbio.202100315 · Cited by 31
Xu, J., Mahajan, K. D., Xue, W., Winter, J. O., Zborowski, M., & Chalmers, J. J. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2012.07.039 · Cited by 30
“, Journal of Magnetism intrinsically magnetic such as deoxygenated red blood cells, magnetic bacteria, and magnetic spores [7–10].”
BackgroundSelf-citationRemoval of malaria-infected red blood cells using magnetic cell separators: A computational study
Kim, J., Massoudi, M., Antaki, J. F., & Gandini, A. (2012) · Applied Mathematics and Computation · doi:10.1016/j.amc.2011.12.057 · Cited by 30
The Applications of BioMEMS in Diagnosis, Cell Biology, and Therapy: A Review
Menon, K., Joy, R. A., Sood, N., & Mittal, R. K. (2013) · BioNanoScience · doi:10.1007/s12668-013-0112-7 · Cited by 29
Design of a low-voltage dielectrophoresis lab-on-the chip to separate tumor and blood cells
Valijam, S., Salehi, A., & Andersson, M. J. (2023) · Microfluidics and Nanofluidics · doi:10.1007/s10404-023-02632-9 · Cited by 27
Magnetophoretic-based microfluidic device for DNA isolation
Hale, C. M., & Darabi, J. (2014) · Biomicrofluidics · doi:10.1063/1.4893772 · Cited by 27
Microfluidic device for continuous magnetophoretic separation of white blood cells
Iliescu, C., Xu, G., Barbarini, E., Avram, M., & Avram, A. M. (2008) · Microsystem Technologies · doi:10.1007/s00542-008-0718-9 · Cited by 27
Synchronous magnetic control of water droplets in bulk ferrofluid
Katsikis, G., Bréant, A., Rinberg, A., & Prakash, M. (2017) · Soft Matter · doi:10.1039/c7sm01973d · Cited by 27
“00 96 1v 2 [ ph ys ic s. fl udy bacteria [Schüler and Frankel(1999),Zborowski et al.(2003)Zborowski, Ostera, Moore, Milliron, Chalmers, and Schechter,Han and Frazier(2004),Lee et al.(2004)Lee, Purdon, Chu, and Westervelt].”
Carpino, F., Zborowski, M., & Williams, P. S. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.11.162 · Cited by 27
Self-citationJin, X., Yazer, M. H., Chalmers, J. J., & Zborowski, M. (2011) · The Analyst · doi:10.1039/c0an01018a · Cited by 26
Self-citationBiosimilar liquid-metal living matter
Li, J., Zhao, X. M., & Liu, J. (2024) · Matter · doi:10.1016/j.matt.2024.04.038 · Cited by 27
Continuous Separation Principles Using External Microaction Forces
Watarai, H. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092551 · Cited by 29
Applications of magnetic and electromagnetic forces in micro-analytical systems
Suwa, M., Tsukahara, S., & Watarai, H. (2023) · Lab on a Chip · doi:10.1039/d2lc00702a · Cited by 26
Open Gradient Magnetic Red Blood Cell Sorter Evaluation on Model Cell Mixtures
Moore, L. R., Nehl, F., Dorn, J., Chalmers, J. J., & Zborowski, M. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2225098 · Cited by 28
“We have measured the intrinsic (label-free) RBC magnetophoretic mobility (MM) in the course of previous studies using a technique referred to as cell tracking velocimetry (CTV), and have shown that it depends on the presence of high-spin hemoglobin in the cell [5].”
Self-citationPark, K. J., Kim, J., Testoff, T. T., Adams, J. R., Poklar, M., Zborowski, M., Venere, M., & Chalmers, J. J. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26973 · Cited by 29
Self-citationYadav, S., Khanam, R., & Singh, J. P. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131303 · Cited by 24
Huang, W., Chang, C.-L., Brault, N. D., Gur, O., Wang, Z., Jalal, S. I., Low, P. S., Ratliff, T. L., Пили, Р., & Savran, C. A. (2017) · Lab on a Chip · doi:10.1039/c6lc01279e · Cited by 29
Development of a High-Throughput Magnetic Separation Device for Malaria-Infected Erythrocytes
Martin, A. B., Wu, W., Kameneva, M. V., & Antaki, J. F. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1925-2 · Cited by 24
Noninvasive assessment of magnetic nanoparticle–cancer cell interactions
Giustini, A. J., Perreard, I. M., Rauwerdink, A. M., Hoopes, P. J., & Weaver, J. B. (2012) · Integrative Biology · doi:10.1039/c2ib20130e · Cited by 23
Metadata
- Authors
- Zborowski, M., Ostera, G. R., Moore, L. R., Milliron, S., Chalmers, J. J., & Schechter, A. N.
- Affiliations
- Cleveland Clinic (US)
- National Institutes of Health (US)
- The Ohio State University (US)
- Corresponding author
- Zborowski, Maciej
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 84
- Issue
- 4
- Pages
- 2638-2645
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1302830
- OpenAlex
- W2055459109
- Semantic Scholar
- ac84d1d1582750c9f8da2a72a80ae705ee302f70
- Cited by
- 260
- References
- 36
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 7 · 2023: 14 · 2022: 12 · 2021: 8 · 2020: 10 · 2019: 11 · 2018: 14 · 2017: 13 · 2016: 16 · 2015: 6 · 2014: 12 · 2013: 18 · 2012: 19
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 3759 d)
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Cancer Institute (R33CA081662, R01CA062349)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geomagnetism and Paleomagnetism Studies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- erythrocytes, methemoglobin, deoxyhemoglobin, paramagnetism, magnetophoretic mobility, magnetic field gradient, cell isolation
- MeSH terms
- Cell Movement, Cell Separation, Electromagnetic Fields, Erythrocytes, Hemoglobins, Humans, Magnetics, Oxyhemoglobins, Rheology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.