A Mathematical Evaluation of the Core Conductor Model
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
THE CONDUCTIVITY OF LIVING TISSUES
Schwan, H. P., & Kay, C. F. (1957) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1957.tb36701.x · Cited by 238
Cited by
Time Constants and Electrotonic Length of Membrane Cylinders and Neurons
Rall, W. (1969) · Biophysical Journal · doi:10.1016/s0006-3495(69)86467-2 · Cited by 751
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
A model of the stimulation of a nerve fiber by electromagnetic induction
Roth, B. J., & Basser, P. J. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55662 · Cited by 363
The electrophysics of a nerve fiber
Scott, A. C. (1975) · Reviews of Modern Physics · doi:10.1103/revmodphys.47.487 · Cited by 305
Goldman, L., & Albus, J. S. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86510-5 · Cited by 275
Closed-Loop Control of Deep Brain Stimulation: A Simulation Study
Santaniello, S., Fiengo, G., Glielmo, L., & Grill, W. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2081377 · Cited by 202
“First, the extracellular potentials generated by the electrode when the stimulus was ON were calculated [24]”
BackgroundMethodThe Extracellular Potential Field of the Single Active Nerve Fiber in a Volume Conductor
Clark, J., & Plonsey, R. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86524-5 · Cited by 183
Self-citationSolid angle theory and the electrocardiogram: Physiologic and quantitative interpretations
Holland, R. P., & Arnsdorf, M. F. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(77)90009-3 · Cited by 161
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
“DISCUSSION Expected Waveform and Amplitude of the Recorded Signal The biophysical basis for our ability to record signals with this technique can be derived from the model describing extracellular potential fields surrounding an active nerve fiber developed by Clark and Plonsey (1,2) and waveform parameters for myelin…”
MethodYoshida, K., Kurstjens, G. A. M., & Hennings, K. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.005 · Cited by 43
Metadata
- Authors
- Clark, J., & Plonsey, R.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1966-01
- Volume
- 6
- Issue
- 1
- Pages
- 95-112
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2049106535
- Cited by
- 173
- References
- 2
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.