Experimental validation of the nerve conduction velocity selective recording technique using a multi-contact cuff electrode
Abstract
The earthworm (Lumbricus terrestris) is presented as an in vitro model of a peripheral nerve containing only two fibers each with distinctly different conduction velocities, the median and lateral giant fibers (MGF and LGF). The worm model is used with a multi-contact cuff electrode to validate the spatial-temporal filtering effect of different electrode contact configurations and the effect of applying a delay adder and matched filter tuned to either the MGF or LGF action potential (AP) to extract conduction direction and velocity from the recording. The results confirmed the known effect of inter-electrode spacing and bipolar and tripolar recording configuration on the AP amplitude. It also demonstrates a crossover point where the amplitude of the tripolar recording is larger than the monopolar recording, an effect of the slower action potential conduction velocities in the worm. The delay adder was found to be an effective velocity sensitive filter, able to discriminate units based on conduction velocity. The matched filter to be an effective means to eliminate artifact and increase signal to noise ratios, however was not found to improve selectivity.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The ability of velocity selection recording to discriminate recorded activity by fiber type has been validated in several acute in vivo studies.
“The ability of VSR to discriminate recorded activity based on fiber type has been validated in several acute in vivo studies [123, 124, 153]; demonstrating this technique in a chronically implanted model would represent a major advancement.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [153]
Cites
Two decades of array signal processing research: the parametric approach
Krim, H., & Viberg, M. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.526899 · Cited by 4,774 · see citing works
Measurement of current‐voltage relations in the membrane of the giant axon of Loligo
Hodgkin, A. L., Huxley, A. F., & Katz, B. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004716 · Cited by 1,749 · see citing works
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833 · see citing works
Time delay estimation for passive sonar signal processing
Carter, G. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163560 · Cited by 484 · see citing works
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., DAVIS, L. A., Jhamandas, J. H., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 211 · see citing works
The active fiber in a volume conductor
Plonsey, R. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324406 · Cited by 206 · see citing works
The Extracellular Potential Field of the Single Active Nerve Fiber in a Volume Conductor
Clark, J. W., & Plonsey, R. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86524-5 · Cited by 186 · see citing works
Some Observations on the Fine Structure of the Giant Nerve Fibers of the Earthworm, Eisenia foetida
Hama, K. (1959) · The Journal of Cell Biology · doi:10.1083/jcb.6.1.61 · Cited by 183 · see citing works
A Mathematical Evaluation of the Core Conductor Model
Clark, J. W., & Plonsey, R. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86642-0 · Cited by 175 · see citing works
FUNCTIONAL ORGANIZATION OF THE GIANT FIBER SYSTEM OF LUMBRICUS
Bullock, T. H. (1945) · Journal of Neurophysiology · doi:10.1152/jn.1945.8.1.55 · Cited by 112 · see citing works
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Struijk, J. J. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78890-8 · Cited by 93 · see citing works
Günther, J. (1976) · The Journal of Comparative Neurology · doi:10.1002/cne.901680405 · Cited by 89 · see citing works
Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording
Taylor, J. T., Donaldson, N., & Winter, J. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347545 · Cited by 79 · see citing works
Patch clamp recordings from membranes which contain gap junction channels
Brink, P. R., & Fan, S. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82705-5 · Cited by 62 · see citing works
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57 · see citing works
A Mathematical Study of Nerve Fiber Interaction
Clark, J. W., & Plonsey, R. (1970) · Biophysical Journal · doi:10.1016/s0006-3495(70)86344-5 · Cited by 55 · see citing works
Signal strength versus cuff length in nerve cuff electrode recordings
Struijk, L. N. S. A., & Struijk, J. J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800785 · Cited by 55 · see citing works
Noise and selectivity of velocity-selective multi-electrode nerve cuffs
Donaldson, N., Rieger, R., Schuettler, M., & Taylor, J. (2008) · Medical and Biological Engineering and Computing · doi:10.1007/s11517-008-0365-4 · Cited by 49 · see citing works
Goldstein, A. (1989) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(89)90072-0 · Cited by 48 · see citing works
Giant Nerve Fibre Activity in Intact, Freely Moving Earthworms
Drewes, C. D., Landa, K. B., & McFall, J. L. (1978) · Journal of Experimental Biology · doi:10.1242/jeb.72.1.217 · Cited by 47 · see citing works
O’Gara, B. A., Vining, E. P., & Drewes, C. D. (1982) · Journal of Neurobiology · doi:10.1002/neu.480130405 · Cited by 38 · see citing works
Wijesinghe, R. S., Gielen, F. L. H., & Wikswo, J. P. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368462 · Cited by 38 · see citing works
Rieger, R., Taylor, J. T., Comi, E., Donaldson, N., Russold, M., Mahony, C. M. O., McLaughlin, J. A., McAdams, E. T., Demosthenous, A., & Jarvis, J. C. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.02.002 · Cited by 32 · see citing works
Fascicle selective recording with a nerve cuff electrode
Struijk, J. J., Haugland, M. K., & Thomsen, M. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.656993 · Cited by 26 · see citing works
Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode
Schüettler, M., Seetohul, V., Taylor, J. T., & Donaldson, N. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260335 · Cited by 15 · see citing works
A beamformer for the acquisition of evoked potentials
McKinley, C. A., & Parker, P. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133234 · Cited by 12 · see citing works
On the spectrum of nerve cuff electrode recordings
Struijk, J. J. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1997.758738 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50 · see citing works
Schuettler, M., Seetohul, V., Rijkhoff, N. J. M., Moeller, F. V., Donaldson, N., & Taylor, J. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090847 · Cited by 19 · see citing works
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278479 · Cited by 15 · see citing works
- Authors
- Yoshida, K., Kurstjens, G. A. M., & Hennings, K.
- Affiliations
- Indiana University – Purdue University Indianapolis (US)
- Aalborg University (DK)
- Aalborg University Hospital (DK)
- Corresponding author
- Yoshida, K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2009-09-16
- Volume
- 31
- Issue
- 10
- Pages
- 1261-1270
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2075344214
- Cited by
- 43
- References
- 28
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 1 · 2016: 3 · 2015: 2 · 2014: 3 · 2013: 4 · 2012: 5
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Medical Engineering & Physics (publishedVersion)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- nerve conduction velocity, earthworms, Lumbricus terrestris, giant fiber, matched filter, electrode spacing, bipolar recording, action potential amplitude, peripheral nerves, signal-to-noise ratio
- MeSH terms
- Action Potentials, Algorithms, Amplifiers, Electronic, Animals, Electric Conductivity, Electrodes, Electrodes, Implanted, Equipment Design, Models, Neurological, Neural Conduction, Neurons, Oligochaeta, Peripheral Nerves, Signal Processing, Computer-Assisted, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review