Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

An intrafascicular electrode for recording of action potentials in peripheral nerves

Malagodi, Mark S., Horch, Kenneth W., Schoenberg, Andrew A. · 1989 · Annals of Biomedical Engineering

Abstract

We are developing a new type of bipolar recording electrode intended for implantation within individual fascicles of mammalian peripheral nerves. In the experiments reported here we used electrodes fabricated from 25 microns diameter Pt wire, 50 microns 90% Pt-10% Ir wire and 7 microns carbon fibers. The electrodes were implanted in the sciatic nerves of rats and in the ulnar nerves of cats. The signal-to-noise ratio of recorded activity induced by nonnoxious mechanical stimulation of the skin and joints was studied as a function of the type of electrode material used, the amount of insulation removed from the recording zone, and the longitudinal separation of the recording zones of bipolar electrode pairs. Both acute and short term (two day) chronic experiments were performed. The results indicate that a bipolar electrode made from Teflon-insulated, 25 microns diameter, 90% Pt-10% Ir wire, having a 1-2 mm long recording zone, can be used for recording of peripheral nerve activity when implanted with one wire inside the fascicle and the other lead level with the first lead, but outside the fascicle. No insulating cuff needs to be placed around the nerve trunk.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02368058

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Research works printed but not linked: 3

  1. Marsolais, E.B. Stages in the development of useful FNS-augmented walking. RESNA Proc. 9th Annl. Conf. Rehab. Techn. 9:279–281; 1986.
  2. Stoehr, H.M.; Bochdansky, T.; Frey, M.; Holle, J.; Kern, H.; Schwanda, G.; Thoma, H. Functional electrostimulation makes paraplegic patients walk again. In: 1st Vienna International Workshop on Functional Electrostimulation. Vienna, Austria: Bioengineering Lab. Van Swieten-Gasse, Austria, 1983; p. 5.4.
  3. Yonezawa, Y.; Ninomiya, I.; Nishiura, N. A printed implantable electrode for recording neural signals in awake animals. IEEE/Ninth Ann. Conf. Eng. Med. Biol. Soc. Ch2513:485–487; 1987.

Cited by

See all 107

Metadata

Authors
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A.
Affiliations
University of Utah (US)
Venue
Annals of Biomedical Engineering
Published
1989-07
Volume
17
Issue
4
Pages
397-410
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2022483102
Cited by
107
References
20
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 4 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 5 · 2016: 4 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 3
FWCI
0.55
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. Public Health Service (G008653199)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
intrafascicular electrodes, peripheral nerve recording, action potential, sciatic nerve, ulnar nerve, carbon fiber electrodes, signal-to-noise ratio
MeSH terms
Action Potentials, Afferent Pathways, Animals, Cats, Electrodes, Implanted, Equipment Design, Peripheral Nerves, Polytetrafluoroethylene, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An intrafascicular electrode for recording of action potentials in peripheral nerves. https://app.cochat.ai/papers/10.1007/bf02368058
The paper
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989). An intrafascicular electrode for recording of action potentials in peripheral nerves. Annals of Biomedical Engineering. https://doi.org/10.1007/bf02368058

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.