An intrafascicular electrode for recording of action potentials in peripheral nerves
Abstract
We are developing a new type of bipolar recording electrode intended for implantation within individual fascicles of mammalian peripheral nerves. In the experiments reported here we used electrodes fabricated from 25 microns diameter Pt wire, 50 microns 90% Pt-10% Ir wire and 7 microns carbon fibers. The electrodes were implanted in the sciatic nerves of rats and in the ulnar nerves of cats. The signal-to-noise ratio of recorded activity induced by nonnoxious mechanical stimulation of the skin and joints was studied as a function of the type of electrode material used, the amount of insulation removed from the recording zone, and the longitudinal separation of the recording zones of bipolar electrode pairs. Both acute and short term (two day) chronic experiments were performed. The results indicate that a bipolar electrode made from Teflon-insulated, 25 microns diameter, 90% Pt-10% Ir wire, having a 1-2 mm long recording zone, can be used for recording of peripheral nerve activity when implanted with one wire inside the fascicle and the other lead level with the first lead, but outside the fascicle. No insulating cuff needs to be placed around the nerve trunk.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [308]
In the citing paper
“For example, intrafascicular electrodes, such as the transverse intrafascicular multichannel electrode (TIME) and the longitudinal intrafascicular electrode (LIFE), transduce signals that have amplitudes less than 100 µVpp [62, 66, 71, 79, 82, 109].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [79]
Citations
Cites
Current Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830
Sunderland, S., & SMITH, J. W. (1969) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-196912000-00013 · Cited by 752
Waxman, S. G. (1983) · Trends in Neurosciences · doi:10.1016/0166-2236(83)90228-x · Cited by 477
Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258 · cited 1×
“Proper insulation of carbon fiber electrodes is still the subject of some uncertainty, the benefits of Parylene notwithstanding (11).”
BackgroundComputation of Impulse Initiation and Saltatory Conduction in a Myelinated Nerve Fiber
Fitzhugh, R. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86837-4 · Cited by 223
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., Davis, L., Jhamandas, J., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 210 · cited 1×
“The most commonly used cuff electrode consists of a slit Silastic tube into which three platinum-iridium wires have been sewn in a circular manner (17).”
MethodThe Extracellular Potential Field of the Single Active Nerve Fiber in a Volume Conductor
Clark, J., & Plonsey, R. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86524-5 · Cited by 183 · cited 1×
“DISCUSSION Expected Waveform and Amplitude of the Recorded Signal The biophysical basis for our ability to record signals with this technique can be derived from the model describing extracellular potential fields surrounding an active nerve fiber developed by Clark and Plonsey (1,2) and waveform parameters for myelin…”
MethodA Mathematical Evaluation of the Core Conductor Model
Clark, J., & Plonsey, R. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86642-0 · Cited by 173 · cited 1×
“DISCUSSION Expected Waveform and Amplitude of the Recorded Signal The biophysical basis for our ability to record signals with this technique can be derived from the model describing extracellular potential fields surrounding an active nerve fiber developed by Clark and Plonsey (1,2) and waveform parameters for myelin…”
MethodKralj, A. R., Bajd, T., Turk, R., Krajnik, J., & Benko, H. (1983) · PubMed · Cited by 159
Peckham, P. H., Mortimer, J. T., & Marsolais, E. B. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363440 · Cited by 145 · cited 1×
“Functional electrical stimulation (FES) of neuromuscular tissue to produce movement or sensation has reached the clinical stage in many research centers: upper extremity FES has been used to restore key and pinch grasp in paraplegics (16), and lower extremity FES has shown promise for restoring walking (10,14,18).”
Background
Research works printed but not linked: 3
- Marsolais, E.B. Stages in the development of useful FNS-augmented walking. RESNA Proc. 9th Annl. Conf. Rehab. Techn. 9:279–281; 1986.
- Stoehr, H.M.; Bochdansky, T.; Frey, M.; Holle, J.; Kern, H.; Schwanda, G.; Thoma, H. Functional electrostimulation makes paraplegic patients walk again. In: 1st Vienna International Workshop on Functional Electrostimulation. Vienna, Austria: Bioengineering Lab. Van Swieten-Gasse, Austria, 1983; p. 5.4.
- Yonezawa, Y.; Ninomiya, I.; Nishiura, N. A printed implantable electrode for recording neural signals in awake animals. IEEE/Ninth Ann. Conf. Eng. Med. Biol. Soc. Ch2513:485–487; 1987.
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“LIFEs are constructed from thin insulated conducting wires, such as Pt-Ir or metallized Kevlar fibers (Malagodi et al., 1989; McNaughton and Horch, 1996; Yoshida et al., 2000; Lawrence et al., 2003); the active site zone is a short length (250–1,500 mm) of the wire bared of the insulation (Fig.”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Self-citation
Metadata
- Authors
- Malagodi, M. S., Horch, K. W., & Schoenberg, A. A.
- Affiliations
- University of Utah (US)
- Venue
- Annals of Biomedical Engineering
- Published
- 1989-07
- Volume
- 17
- Issue
- 4
- Pages
- 397-410
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2022483102
- Semantic Scholar
- e736a062a7782b9c6876836a05fc0cc19eadde30
- Cited by
- 107
- References
- 20
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 4 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 5 · 2016: 4 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 3
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Public Health Service (G008653199)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intrafascicular electrodes, peripheral nerve recording, action potential, sciatic nerve, ulnar nerve, carbon fiber electrodes, signal-to-noise ratio
- MeSH terms
- Action Potentials, Afferent Pathways, Animals, Cats, Electrodes, Implanted, Equipment Design, Peripheral Nerves, Polytetrafluoroethylene, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An intrafascicular electrode for recording of action potentials in peripheral nerves. https://app.cochat.ai/papers/10.1007/bf02368058
- The paper
- Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989). An intrafascicular electrode for recording of action potentials in peripheral nerves. Annals of Biomedical Engineering. https://doi.org/10.1007/bf02368058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.