Wavelength dependence of cell cloning efficiency after optical trapping
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Acceleration and Trapping of Particles by Radiation Pressure
Ashkin, A. (1970) · Physical Review Letters · doi:10.1103/physrevlett.24.156 · Cited by 5,013
Optical trapping and manipulation of single cells using infrared laser beams
Ashkin, A., Dziedzic, J. M., & Yamane, T. (1987) · Nature · doi:10.1038/330769a0 · Cited by 2,303
Optical Trapping and Manipulation of Viruses and Bacteria
Ashkin, A., & Dziedzic, J. M. (1987) · Science · doi:10.1126/science.3547653 · Cited by 2,191
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038 · cited 2×
“, 1990); to study cellular motors (Kuo and Sheetz, 1993; Block et al., 1990); for cell sorting (Buican et al.”
BackgroundOptical properties of water in the near infrared*
Palmer, K. F., & Williams, D. (1974) · Journal of the Optical Society of America · doi:10.1364/josa.64.001107 · Cited by 709
Relaxation of a Single DNA Molecule Observed by Optical Microscopy
Perkins, T. T., Quake, S. R., Smith, D. E., & Chu, S. (1994) · Science · doi:10.1126/science.8171336 · Cited by 638
Applications of Laser Radiation Pressure
Ashkin, A. (1980) · Science · doi:10.1126/science.210.4474.1081 · Cited by 609
Compliance of bacterial flagella measured with optical tweezers
Block, S. M., Blair, D. F., & Berg, H. C. (1989) · Nature · doi:10.1038/338514a0 · Cited by 447
Cited by
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Neuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
Optical trapping and manipulation of neutral particles using lasers
Ashkin, A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.10.4853 · Cited by 1,474
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
Microfluidic sorting of mammalian cells by optical force switching
Wang, M. M., Tu, E., Raymond, D. E., Yang, J. M., Zhang, H., Hagen, N., Dees, B., Mercer, E. M., Forster, A. H., Kariv, I., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1050 · Cited by 690
Characterization of Photodamage to Escherichia coli in Optical Traps
Neuman, K. C., Chadd, E. H., Liou, G. F., Bergman, K., & Block, S. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77117-1 · Cited by 687
Optical manipulation from the microscale to the nanoscale: fundamentals, advances and prospects
Gao, D., Ding, W., Nieto-Vesperinas, M., Ding, X., Rahman, M., Zhang, T., Lim, C., & Qiu, C.-W. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.39 · Cited by 642
History of optical trapping and manipulation of small-neutral particle, atoms, and molecules
Ashkin, A. (2000) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.902132 · Cited by 635
Centonze, V. E., & White, J. G. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77643-x · Cited by 460
History of Optical Trapping and Manipulation of Small Neutral Particles, Atoms, and Molecules
Ashkin, A. (2001) · Springer Series in Chemical Physics · doi:10.1007/978-3-642-56544-1_1 · Cited by 427
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Unveiling in Vivo Subcutaneous Thermal Dynamics by Infrared Luminescent Nanothermometers
Ximendes, E. C., Santos, W. Q., Rocha, U., Kagola, U. K., Sanz-Rodríguez, F., Fernández, N., Gouveia-Neto, A. D. S., Bravo, D., Domingo, A. M., del Rosal, B., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04611 · Cited by 325
Laser-guided direct writing of living cells
Odde, D. J., & Renn, M. J. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000205)67:3<312::aid-bit7>3.0.co;2-f · Cited by 297
Surgical applications of femtosecond lasers
Chung, S. H., & Mazur, E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910053 · Cited by 281
Jet‐based methods to print living cells
Ringeisen, B. R., Othon, C. M., Barron, J. A., Young, D., & Spargo, B. J. (2006) · Biotechnology Journal · doi:10.1002/biot.200600058 · Cited by 249
“For biological suspensions, a laser with a wavelength in the near-infrared part of the spectrum is chosen because it has been found to cause the least damage to living cells [72, 73].”
BackgroundHolographic optical tweezers and their relevance to lab on chip devices
Padgett, M., & Di Leonardo, R. (2011) · Lab on a Chip · doi:10.1039/c0lc00526f · Cited by 235
Microfluidics and Raman microscopy: current applications and future challenges
Chrimes, A. F., Khoshmanesh, K., Stoddart, P. R., Mitchell, A., & Kalantar-zadeh, K. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35515b · Cited by 217
Cell Visco-Elasticity Measured with AFM and Optical Trapping at Sub-Micrometer Deformations
Nawaz, S., Sánchez, P., Bodensiek, K., Li, S., Simons, M., & Schaap, I. A. T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045297 · Cited by 209
“The used wavelength of 980 nm was specifically chosen to minimize the induced cell damage [37].”
MethodResource Letter: LBOT-1: Laser-based optical tweezers
Lang, M. J., & Block, S. M. (2003) · American Journal of Physics · doi:10.1119/1.1532323 · Cited by 208
Cell separation by non-inertial force fields in microfluidic systems
Tsutsui, H., & Ho, C.-M. (2009) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2008.08.006 · Cited by 190
Optical Tweezers Cause Physiological Damage to Escherichia coli and Listeria Bacteria
Rasmussen, M. B., Oddershede, L. B., & Siegumfeldt, H. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.02265-07 · Cited by 173
“Earlier investigations aiming at quantifying damage caused by optical tweezers have been performed on mammalian cells (11, 14, 15, 22), on E.”
BackgroundTemperature Control Methods in a Laser Tweezers System
Mao, H., Ricardo Arias-Gonzalez, J., Smith, S. B., Tinoco, I., & Bustamante, C. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.054536 · Cited by 165
“In addition, two studies (28,29) have indicated that 980 nm light is the least damaging of the first three NIR wavelengths to living cells.”
Background
Metadata
- Authors
- Liang, H., Vu, K. T., Krishnan, P., Trang, T. C., Shin, D., Kimel, S., & Berns, M. W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1996-03
- Volume
- 70
- Issue
- 3
- Pages
- 1529-1533
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1979340466
- Cited by
- 261
- References
- 17
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.