Electropermeabilization of Mammalian Cells to Macromolecules: Control by Pulse Duration
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Gene transfer into mouse lyoma cells by electroporation in high electric fields.
Neumann, E., Schaefer-Ridder, M., Wang, Y., & Hofschneider, P. H. (1982) · The EMBO Journal · doi:10.1002/j.1460-2075.1982.tb01257.x · Cited by 2,502
Electroporation of cell membranes
Tsong, T. Y. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82054-9 · Cited by 1,094
Electroporation and Electrofusion in Cell Biology
(1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2 · Cited by 942
Deininger, P. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90283-y · Cited by 888
Electroporation for the efficient transfection of mammalian cells with DNA
Chu, G., Hayakawa, H., & Berg, P. (1987) · Nucleic Acids Research · doi:10.1093/nar/15.3.1311 · Cited by 832
Electrochemotherapy potentiation of antitumour effect of bleomycin by local electric pulses
Mir, L. M., Orlowski, S., Belehradek, J., & Paoletti, C. (1991) · European Journal of Cancer and Clinical Oncology · doi:10.1016/0277-5379(91)90064-k · Cited by 643
Electroporation of mammalian skin: a mechanism to enhance transdermal drug delivery.
Prausnitz, M. R., Bose, V. G., Langer, R., & Weaver, J. C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.22.10504 · Cited by 640
Formation and resealing of pores of controlled sizes in human erythrocyte membrane
KINOSITA, K., & TSONG, T. Y. (1977) · Nature · doi:10.1038/268438a0 · Cited by 501
In vivo electroporation and stable transformation of skin cells of newborn mice by plasmid DNA
Titomirov, A. V., Sukharev, S., & Kistanova, E. (1991) · Biochimica et Biophysica Acta (BBA) - Gene Structure and Expression · doi:10.1016/0167-4781(91)90162-f · Cited by 405
Cited by
Membrane Electroporation and Electropermeabilization: Mechanisms and Models
Kotnik, T., Rems, L., Tarek, M., & Miklavčič, D. (2019) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-052118-115451 · Cited by 813
“the transport, with longer (approximately milliseconds) pulses generally required for sufficient electrophoretic drag on DNA to enable DNA–membrane interaction (124, 165, 211).”
BackgroundIntracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Teissie, J., Golzio, M., & Rols, M. P. (2005) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2005.05.006 · Cited by 622
Self-citationGothelf, A., Mir, L. M., & Gehl, J. (2003) · Cancer Treatment Reviews · doi:10.1016/s0305-7372(03)00073-2 · Cited by 549
Cell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
Modeling Electroporation in a Single Cell
Krassowska, W., & Filev, P. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.094235 · Cited by 501
“Alternatively, transport may be sufficiently effective but long pulses required for the uptake (at least 1 ms (53,54)) increase the probability of cells dying.”
BackgroundDirect visualization at the single-cell level of electrically mediated gene delivery
Golzio, M., Teissié, J., & Rols, M.-P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.022646499 · Cited by 411
Self-citationMiklavčič, D., Šemrov, D., Mekid, H., & Mir, L. M. (2000) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(00)00101-x · Cited by 366
Melikov, K. C., Frolov, V. A., Shcherbakov, A., Samsonov, A. V., Chizmadzhev, Y. A., & Chernomordik, L. V. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76153-x · Cited by 267
Escoffre, J.-M., Portet, T., Wasungu, L., Teissié, J., Dean, D., & Rols, M.-P. (2009) · Molecular Biotechnology · doi:10.1007/s12033-008-9121-0 · Cited by 257
Self-citationThe Effects of Intense Submicrosecond Electrical Pulses on Cells
Deng, J., Schoenbach, K. H., Stephen Buescher, E., Hair, P. S., Fox, P. M., & Beebe, S. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75076-0 · Cited by 239
“membrane integrity in living cells (Rols and Teissie, 1998).”
Effect of electric field induced transmembrane potential on spheroidal cells: theory and experiment
Valic, B., Golzio, M., Pavlin, M., Schatz, A., Faurie, C., Gabriel, B., Teissi�, J., Rols, M.-P., & Miklavcic, D. (2003) · European Biophysics Journal · doi:10.1007/s00249-003-0296-9 · Cited by 223
“These electric field parameters were used in previous studies and gave efficient levels of electropermeabilization, having at the same time relatively good cell viability (Rols and Teissié 1998; Rols et al. 1998b).”
MethodSelf-citationBuckow, R., Ng, S., & Toepfl, S. (2013) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12026 · Cited by 216
Equivalent Pulse Parameters for Electroporation
Pucihar, G., Krmelj, J., Reberšek, M., Napotnik, T., & Miklavčič, D. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167232 · Cited by 214
“However, finding a suitable combination of pulse parameters proved to be a difficult task, since simple relations , such as keeping the same energy of the pulses, turned out to be inefficient [1], [32].”
BackgroundGene Electrotransfer: A Mechanistic Perspective
Rosazza, C., Haberl Meglic, S., Zumbusch, A., Rols, M.-P., & Miklavcic, D. (2016) · Current Gene Therapy · doi:10.2174/1566523216666160331130040 · Cited by 209
“At fixed electric field strength, for pulse durations larger than 100 s and pulse number larger than 5, the permeabilization rate reaches a plateau [127, 138].”
BackgroundMethodInfluentialSelf-citationModel of Creation and Evolution of Stable Electropores for DNA Delivery
Smith, K. C., Neu, J. C., & Krassowska, W. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74334-9 · Cited by 188
“…in DNA uptake after electric pulses, some researchers postulated that DNA entry into cells relies on the DNA-membrane interactions, which may be facilitated by a collection of small, 1 nm pores (Neumann et al., 1996; Rols and Teissié, 1998; Rols et al., 1998b; Sukharev et al., 1992, 1994).”
BackgroundInfluentialIn vitro electroporation detection methods – An overview
Batista Napotnik, T., & Miklavčič, D. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2017.12.005 · Cited by 187
“It has been used to test pulse parameter effects (duration, field strength, pulse number) on electroporation [196,197,199,201,202], to detect the site of electroporation and observe dye influx in single cells on an electroporation chip [23] and to determine the role of electroporation in cell fusion [201].”
MethodTutorial: Electroporation of cells in complex materials and tissue
Rems, L., & Miklavčič, D. (2016) · Journal of Applied Physics · doi:10.1063/1.4949264 · Cited by 180
Kinetics of Transmembrane Transport of Small Molecules into Electropermeabilized Cells
Pucihar, G., Kotnik, T., Miklavčič, D., & Teissié, J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.135541 · Cited by 179
“6 C shows, at a given field strength the fluorescence detected 8 s after the pulse increases with the pulse duration in a fairly linear manner, as reported by Rols and Teissié (8).”
InfluentialSelf-citationThe Effect of Intense Subnanosecond Electrical Pulses on Biological Cells
Schoenbach, K. H., Xiao, S., Joshi, R. P., Camp, J. T., Heeren, T., Kolb, J. F., & Beebe, S. J. (2008) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2008.918786 · Cited by 166
“membrane integrity, uptake of this marker after pulsing has also been reported for viable cells [21].”
BackgroundRole of pulse shape in cell membrane electropermeabilization
Kotnik, T., Pucihar, G., Reberšek, M., Miklavčič, D., & Mir, L. M. (2003) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(03)00173-1 · Cited by 166
“Investigations of the role of the amplitude, number, and duration of unipolar rectangular pulses have been the subject of several comprehensive studies [16–20].”
BackgroundMethodCell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Mir, L. M., Flisar, K., Puc, M., & Miklavčič, D. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00114-1 · Cited by 159
A 3D in vitro spheroid model as a way to study the mechanisms of electroporation
Wasungu, L., Escoffre, J.-M., Valette, A., Teissie, J., & Rols, M.-P. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.03.035 · Cited by 58
Self-citationJaeger, D., Hübner, W., Huser, T., Mussgnug, J. H., & Kruse, O. (2017) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2017.03.011 · Cited by 31
Metadata
- Authors
- Rols, M.-P., & Teissié, J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-09
- Volume
- 75
- Issue
- 3
- Pages
- 1415-1423
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1967093606
- Cited by
- 347
- References
- 41
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.