CoChat

Comparison of Secretory Responses as Measured by Membrane Capacitance and by Amperometry

Open access
Haller, Mirjam, Heinemann, Christian, Chow, Robert H., Heidelberger, Ruth, Neher, Erwin · 1998 · Biophysical Journal
Cited by 82

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We have compared capacitance and amperometric measurements in bovine chromaffin cells when secretion was elicited by flash photolysis of caged-calcium or step depolarizations. Total amperometric charge depended linearly on the amount of capacitance increase in both types of experiments. Furthermore, the properties of resolvable amperometric spikes after flashes were comparable to those observed after depolarizations, and their timing was compatible with the rate of capacitance increase. For a more detailed comparison, we used Monte Carlo simulations of multiple amperometric events occurring randomly over the surface of a sphere and summing together, to generate a reference amperometric signal for a given measured capacitance increase. Even after correction for endocytotic processes, the time courses of the integrated experimental records lagged behind the integrated Monte Carlo records by approximately 50 ms in flash and depolarization experiments. This delay was larger by approximately 40 ms than what can be expected from the "pre-foot delay" or the foot duration. Possible sources for the remaining delay could be diffusional barriers like the patch-pipette and the chamber bottom, which are not taken into account in the model. We also applied a novel type of fluctuation analysis to estimate the relative quantum size of an amperometric event. On average the estimates from experimental amperometric traces, in both flash and depolarization experiments, were 3-5 times smaller than estimates from simulated ones. This discrepancy can be due to contributions to the amperometric current from small vesicles, preferred release from cellular regions orientated toward the chamber bottom, or abundance of "foot-only" events. In conclusion, amperometric signals in flash and depolarization experiments displayed similar delayed average time courses and a lower estimate for the relative quantum size compared to the modeled amperometric signals. However, individual amperometric spikes were in agreement with expectations derived from capacitance signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0006-3495(98)77917-2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 82

Metadata

Authors
Haller, M., Heinemann, C., Chow, R. H., Heidelberger, R., & Neher, E.
Venue
Biophysical Journal
Publisher
Elsevier BV
Published
1998-04
Volume
74
Issue
4
Pages
2100-2113
ISSN
0006-3495 (ISSN-L)
OpenAlex
W1987368066
Cited by
82
References
2
FWCI
2.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Secretory Responses as Measured by Membrane Capacitance and by Amperometry. https://app.cochat.ai/papers/10.1016/s0006-3495(98)77917-2
The paper
Haller, M., Heinemann, C., Chow, R. H., Heidelberger, R., & Neher, E. (1998). Comparison of Secretory Responses as Measured by Membrane Capacitance and by Amperometry. Biophysical Journal. https://doi.org/10.1016/s0006-3495(98)77917-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.