Separation of Polystyrene Microbeads Using Dielectrophoretic/Gravitational Field-Flow-Fractionation
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The characterization of a dielectrophoretic/gravitational field-flow-fractionation (DEP/G-FFF) system using model polystyrene (PS) microbeads is presented. Separations of PS beads of different surface functionalization (COOH and none) and different sizes (6, 10, and 15 microm in diameter) are demonstrated. To investigate the factors influencing separation performance, particle elution times were determined as a function of particle suspension conductivity, fluid flow rate, and applied field frequency and voltage. Experimental data were analyzed using a previously reported theoretical model and good agreement between theory and experiment was found. It was shown that separation of PS beads was based on the differences in their effective dielectric properties. Particles possessing different dielectric properties were positioned at different heights in a fluid-flow profile in a thin chamber by the balance of DEP and gravitational forces, transported at different velocities under the influence of the fluid flow, and thereby separated. To explore hydrodynamic (HD) lift effects, velocities of PS beads were determined as a function of fluid flow rate in the separation chamber when no DEP field was applied. In this case, particle equilibrium height positions were governed solely by the balance of HD lift and gravitational forces. It was concluded that under the experimental conditions reported here, the DEP force was the dominant factor in controlling particle equilibrium height and that HD lift force played little role in DEP/G-FFF operation. Finally, the influence of various experimental parameters on separation performance was discussed for the optimization of DEP/G-FFF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
Numerical Recipes: The Art of Scientific Computing
Ziegel, E. (1987) · Technometrics · doi:10.1080/00401706.1987.10488304 · Cited by 6,702
The lift on a small sphere in a slow shear flow
Saffman, P. G. (1965) · Journal of Fluid Mechanics · doi:10.1017/s0022112065000824 · Cited by 3,426
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Inertial migration of rigid spheres in two-dimensional unidirectional flows
Ho, B. P., & Leal, L. G. (1974) · Journal of Fluid Mechanics · doi:10.1017/s0022112074001431 · Cited by 821
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Self-citationDielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Self-citationInteractions between electromagnetic fields and cells
Chiabrera, A., Nicolini, C. A., & Schwan, H. P. (1985) · Medical Entomology and Zoology · Cited by 389
Pethig, R., Huang, Y., Wang, X.-B., & Burt, J. P. H. (1992) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/25/5/022 · Cited by 312
Self-citation
Cited by
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Self-citationParticle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Separation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523
Isolation of rare cells from cell mixtures by dielectrophoresis
Gascoyne, P. R. C., Noshari, J., Anderson, T. J., & Becker, F. F. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800373 · Cited by 436
Self-citationDielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321
Self-citationRare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Microsample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
Self-citationIsolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
Self-citationAntibody-independent isolation of circulating tumor cells by continuous-flow dielectrophoresis
Shim, S., Stemke-Hale, K., Tsimberidou, A. M., Noshari, J., Anderson, T. E., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774304 · Cited by 215
Self-citationMorgan, H., Izquierdo, A. G., Bakewell, D., Green, N. G., & Ramos, A. (2001) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/34/10/316 · Cited by 209
Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array
Choi, S., & Park, J.-K. (2005) · Lab on a Chip · doi:10.1039/b505088j · Cited by 186
Biomimetic technique for adhesion-based collection and separation of cells in a microfluidic channel
Chang, W. C., Lee, L. P., & Liepmann, D. (2005) · Lab on a Chip · doi:10.1039/b400455h · Cited by 166
Choi, S., & Park, J.-K. (2007) · Lab on a Chip · doi:10.1039/b701227f · Cited by 162
Continuous dielectrophoretic cell separation microfluidic device
Li, Y., Dalton, C., Crabtree, H. J., Nilsson, G., & Kaler, K. V. I. S. (2007) · Lab Chip · doi:10.1039/b613344d · Cited by 158
A three-dimensional dielectrophoretic particle focusing channel for microcytometry applications
Yu, C., Vykoukal, J., Vykoukal, D. M., Schwartz, J. A., Shi, L., & Gascoyne, P. R. C. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844839 · Cited by 158
“On the other hand, at voltages below 5 V, the dielectrophoretic force was too weak to hold the particles at the center of the channel because the dielectrophoretic force falls exponentially with the distance from the edges of the electrodes [ 30 ].”
BackgroundSelf-citation
Metadata
- Authors
- Wang, X.-B., Vykoukal, J., Becker, F. F., & Gascoyne, P. R. C.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-05
- Volume
- 74
- Issue
- 5
- Pages
- 2689-2701
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2067576282
- Cited by
- 175
- References
- 22
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.