The DOI matches its Crossref record.
Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons
Open accessAbstract
A video-rate (30 frames/s) scanning two-photon excitation microscope has been successfully tested. The microscope, based on a Nikon RCM 8000, incorporates a femtosecond pulsed laser with wavelength tunable from 690 to 1050 nm, prechirper optics for laser pulse-width compression, resonant galvanometer for video-rate point scanning, and a pair of nonconfocal detectors for fast emission ratioing. An increase in fluorescent emission of 1.75-fold is consistently obtained with the use of the prechirper optics. The nonconfocal detectors provide another 2.25-fold increase in detection efficiency. Ratio imaging and optical sectioning can therefore be performed more efficiently without confocal optics. Faster frame rates, at 60, 120, and 240 frames/s, can be achieved with proportionally reduced scan lines per frame. Useful two-photon images can be acquired at video rate with a laser power as low as 2.7 mW at specimen with the genetically modified green fluorescent proteins. Preliminary results obtained using this system confirm that the yellow "cameleons" exhibit similar optical properties as under one-photon excitation conditions. Dynamic two-photon images of cardiac myocytes and ratio images of yellow cameleon-2.1, -3.1, and -3.1nu are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
FUKUMURA, D., DUDA, D. G., MUNN, L. L., & JAIN, R. K. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00029.x · Cited by 451
Two-Photon Microscopy of Cells and Tissue
Rubart, M. (2004) · Circulation Research · doi:10.1161/01.res.0000150593.30324.42 · Cited by 339
Simultaneous two-photon calcium imaging at different depths with spatiotemporal multiplexing
Cheng, A., Gonçalves, J. T., Golshani, P., Arisaka, K., & Portera-Cailliau, C. (2011) · Nature Methods · doi:10.1038/nmeth.1552 · Cited by 289
Metadata
- Authors
- Fan, G. Y., Fujisaki, H., Miyawaki, A., Tsay, R.-K., Tsien, R. Y., & Ellisman, M. H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 76
- Issue
- 5
- Pages
- 2412-2420
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1997192016
- Cited by
- 231
- References
- 0
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons. https://app.cochat.ai/papers/10.1016/s0006-3495(99)77396-0
- The paper
- Fan, G. Y., Fujisaki, H., Miyawaki, A., Tsay, R.-K., Tsien, R. Y., & Ellisman, M. H. (1999). Video-Rate Scanning Two-Photon Excitation Fluorescence Microscopy and Ratio Imaging with Cameleons. Biophysical Journal. https://doi.org/10.1016/s0006-3495(99)77396-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.