Human hearing enhanced by noise11Published on the World Wide Web on 23 May 2000.
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477
Gammaitoni, L., Hänggi, P., Jung, P., & Marchesoni, F. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.223 · Cited by 5,443
Stochastic Resonance: From Suprathreshold Stochastic Resonance to Stochastic Signal Quantization
McDonnell, M. D., Stocks, N. G., Pearce, C. E. M., & Abbott, D. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511535239 · Cited by 2,403
Stochastic resonance and the benefits of noise: from ice ages to crayfish and SQUIDs
Wiesenfeld, K., & Moss, F. (1995) · Nature · doi:10.1038/373033a0 · Cited by 1,830
Noise enhancement of information transfer in crayfish mechanoreceptors by stochastic resonance
Douglass, J. K., Wilkens, L., Pantazelou, E., & Moss, F. (1993) · Nature · doi:10.1038/365337a0 · Cited by 1,432
Auditory-nerve response from cats raised in a low-noise chamber
Liberman, M. C. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.381736 · Cited by 1,203
Broadband neural encoding in the cricket cereal sensory system enhanced by stochastic resonance
Levin, J. E., & Miller, J. P. (1996) · Nature · doi:10.1038/380165a0 · Cited by 672
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“…averaged data across all subjects. plitude stimuli at low frequencies [22], a biphasic pulse The dashed line represents a hypothetical masking growth function. signal (100-ms per phase), in addition to the standard Standard deviations for the three threshold measures ranged from 0.1 to 4…”
BackgroundInfluentialNoise-enhanced tactile sensation
Collins, J. J., Imhoff, T. T., & Grigg, P. (1996) · Nature · doi:10.1038/383770a0 · Cited by 482
Responses to amplitude-modulated tones in the auditory nerve of the cat
Joris, P. X., & Yin, T. C. T. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402757 · Cited by 444
Cited by
Stochastic resonance and sensory information processing: A tutorial and review of application
Moss, F., Ward, L. M., & Sannita, W. G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.09.014 · Cited by 994
Acoustic Communication in Noise
Brumm, H., & Slabbekoorn, H. (2005) · Advances in the Study of Behavior · doi:10.1016/s0065-3454(05)35004-2 · Cited by 973
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Self-citationLiu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Noise-Enhanced Human Balance Control
Priplata, A., Niemi, J., Salen, M., Harry, J., Lipsitz, L. A., & Collins, J. J. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.238101 · Cited by 357
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Self-citationWard, L. M. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/2525.001.0001 · Cited by 231
Stimulus-dependent dopamine release in attention-deficit/hyperactivity disorder.
Sikström, S., & Söderlund, G. (2007) · Psychological Review · doi:10.1037/0033-295x.114.4.1047 · Cited by 205
van der Groen, O., & Wenderoth, N. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4519-15.2016 · Cited by 199
“For example, adding an optimal level of noise to weak visual (Riani and Simonotto, 1994; Simonotto et al., 1997; Ward et al., 2001), tactile (Collins et al., 1995; Collins et al., 1996), or auditory stimuli (Zeng et al., 2000) has been shown to significantly enhance detection performance.”
BackgroundBehavioral Stochastic Resonance within the Human Brain
Kitajo, K., Nozaki, D., Ward, L. M., & Yamamoto, Y. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.218103 · Cited by 188
A biomimetic neural encoder for spiking neural network
Subbulakshmi Radhakrishnan, S., Sebastian, A., Oberoi, A., Das, S., & Das, S. (2021) · Nature Communications · doi:10.1038/s41467-021-22332-8 · Cited by 174
The effects of background white noise on memory performance in inattentive school children
Söderlund, G. B., Sikström, S., Loftesnes, J. M., & Sonuga-Barke, E. J. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-55 · Cited by 173
“For instance, SR has been found in several modalities; audition [15], vision [16], and touch [17] where stochastic noise improves sensory discriminability.”
Speech dynamic range and its effect on cochlear implant performance
Zeng, F.-G., Grant, G., Niparko, J., Galvin, J., Shannon, R., Opie, J., & Segel, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1423926 · Cited by 171
Self-citationPredictive coding and stochastic resonance as fundamental principles of auditory phantom perception.
Schilling, A., Sedley, W., Gerum, R., Metzner, C., Tziridis, K., Maier, A., Schulze, H., Zeng, F.-G., Friston, K. J., & Krauss, P. (2023) · Brain · doi:10.1093/brain/awad255 · Cited by 70
Self-citation
Metadata
- Authors
- Zeng, F.-G., Fu, Q.-J., & Morse, R.
- Venue
- Brain Research
- Publisher
- Elsevier BV
- Published
- 2000-06
- Volume
- 869
- Issue
- 1-2
- Pages
- 251-255
- ISSN
- 0006-8993 (ISSN-L)
- OpenAlex
- W1983297885
- Cited by
- 309
- References
- 23
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.