Current status of monophasic action potential recording: theories, measurements and interpretations
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Time for primary review 26 days. Monophasic action potentials (MAPs) are extracellularly recorded wave forms that, under optimal conditions, can reproduce the repolarization time course of transmembrane action potentials (TAPs) with high fidelity [1–3]. While TAP recordings require the impalement of an individual cardiac cell by a glass-microelectrode and therefore generally are limited to in vitro preparations, MAPs can be recorded from the endocardium and epicardium of the in situ beating heart, including that of human subjects. MAP recordings therefore are suitable for studying the characteristics of local myocardial electrophysiology, especially of repolarization, in the clinical setting. This has made MAP recordings an important bridge between basic and clinical electrophysiology in multiple areas of arrhythmia research [4]. Despite the growing use of the MAP recording method, there still is surprisingly little hard data on the exact mechanism by which MAPs are created and recorded. New methods for recording MAPs recently have been proposed, and new theories and models have been suggested to explain the mechanisms that underlie the genesis of the MAP signal. There have been attempts to record MAPs from sites within the myocardial wall, an effort spurred on by the discovery that mid-myocardial cells (M-cells) have different repolarization characteristics than either epicardial or endocardial cells [5], and these different characteristics have been found to be important for the development of torsade de pointes arrhythmias [6]. This article attempts to review the available information on the MAP genesis and its particular recording modes. It also highlights some important MAP quality criteria and guidelines for correct interpretation of MAPs and how to avoid artifacts. Last but not least, important differences between unipolar and bipolar recordings of both MAPs and conventional electrograms will be discussed, as they pertain to the fidelity and spatial resolution of these recordings. The first MAP was recorded in 1882 by Burdon-Sanderson and Page [7]who placed one electrode on the intact epicardial surface and the other on an injured site of a frog heart, and thereby captured the phasic electrical changes of the cardiac cycle on a charcoal-covered recording drum. Burdon-Sanderson and Page produced this injury by cutting into the myocardium, and termed these recordings monophasic action currents (later to be replaced by monophasic action potentials). Until then, electrodes placed on intact heart tissue had been recording multiphasic deflections, similar to those recorded today in the human electrophysiology laboratory by conventional electrode catheters; so the term monophasic was a logical choice. It was believed for several decades that such monophasic action potentials could only be produced by traumatic tissue injury or cellular disruption. Methods such as cutting, stabbing or burning of a myocardial site were invented to produce monophasic ‘injury’ currents [8]. In 1934, Schütz [9]introduced the suction electrode for experimental MAP recording. In 1969, Korsgren et al. [10]used a suction electrode catheter in a patient and recorded, for the first time, MAPs from the in situ ventricular endocardium. This pioneering step subsequently was amplified by the work of Olsson and coworkers [11–13]who refined the suction electrode technique and demonstrated the value of MAP recording in exploring human cardiac electrophysiology, mainly of the right atrium. Injury was still deemed necessary and to do this ‘cautiously’ in the human heart by suction technique required the use of three-way stop cocks, bubble filters to prevent air emboli and other precautions [13]. Because this technique was cumbersome and raised patient safety concerns, the suction electrode technique never gained wide acceptance in the clinical electrophysiological laboratory (nor FDA approval). The first nontraumatic method for recording MAPs was published in 1935 by Jochim et al. [14]. These authors demonstrated that MAPs can be obtained by simply pressing an electrode against the epicardium of the toad ventricle while another electrode merely touched the nearby epicardium (Fig. 1). They also showed that the MAP is positive with respect to zero if the pressure electrode is the active electrode (connected to the positive amplifier input). This important observation went largely unnoticed for many years. However, their observation was in both methodology and interpretation surprisingly similar to the current principle of recording MAPs by contact electrode. The ‘contact electrode technique’ for clinical use was developed between 1980 and 1983 by Franz et al. [15, 16]. With the contact electrode technique, MAP recordings can be obtained from the human endocardium or epicardium without suction but rather by pressing a nonpolarizable electrode gently against the endocardium or epicardium. Catheters and probes for endocardial and epicardial MAP rec
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac resting and action potentials recorded with an intracellular electrode
Draper, M. H., & Weidmann, S. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004653 · Cited by 508
Franz, M. R., Swerdlow, C. D., Liem, L. B., & Schaefer, J. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113706 · Cited by 457
Self-citationDownar, E., Janse, M. J., & Durrer, D. (1977) · Circulation · doi:10.1161/01.cir.56.2.217 · Cited by 450
Franz, M. R., Cima, R., Wang, D., Profitt, D., & Kurz, R. (1992) · Circulation · doi:10.1161/01.cir.86.3.968 · Cited by 411
Self-citationFranz, M. R., Bargheer, K., Rafflenbeul, W., Haverich, A., & Lichtlen, P. R. (1987) · Circulation · doi:10.1161/01.cir.75.2.379 · Cited by 352
Self-citationDynamic Tracking of Cardiac Vulnerability by Complex Demodulation of the T Wave
Nearing, B. D., Huang, A. H., & Verrier, R. L. (1991) · Science · doi:10.1126/science.2017682 · Cited by 323
Mechanisms underlying early and delayed afterdepolarizations induced by catecholamines
Priori, S. G., & Corr, P. B. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.6.h1796 · Cited by 322
Contraction-excitation feedback in myocardium. Physiological basis and clinical relevance.
Lab, M. J. (1982) · Circulation Research · doi:10.1161/01.res.50.6.757 · Cited by 304 · cited 1×
“tation coupling [ 45 ] or mechanoelectrical feedback [46], repolarization levels [58,59].”
Effect of intracellular injection of calcium and strontium on cell communication in heart.
De Mello, W. C. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011051 · Cited by 302
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Self-citationComparison of cardiac monophasic action potentials recorded by intracellular and suction electrodes
Hoffman, B. F., Cranefield, P. F., Lepeschkin, E., Surawicz, B., & Herrlich, H. C. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.196.6.1297 · Cited by 248 · cited 1×
“[1] Because MAPs are directly at the myocardial surface [78].”
Long-term recording of monophasic action potentials from human endocardium
Franz, M. R. (1983) · The American Journal of Cardiology · doi:10.1016/0002-9149(83)90199-6 · Cited by 218
Self-citationMethod and theory of monophasic action potential recording
Franz, M. R. (1991) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(91)90002-4 · Cited by 209
Self-citationMechanically induced action potential changes and arrhythmia in isolated and in situ canine hearts
Franz, M. R., Burkhoff, D., Yue, D. T., & SAGAWA, K. (1989) · Cardiovascular Research · doi:10.1093/cvr/23.3.213 · Cited by 200
Self-citationVos, M. A., Verduyn, S. C., Gorgels, A. P. M., Lipcsei, G. C., & Wellens, H. J. J. (1995) · Circulation · doi:10.1161/01.cir.91.3.864 · Cited by 195
In vitro validation of a new cardiac catheter technique for recording monophasic action potentials
FRANZ, M. R., BURKHOFF, D., SPURGEON, H., WEISFELDT, M. L., & LAKATTA, E. G. (1986) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a061954 · Cited by 176 · cited 14×
“The smaller rise in velocity of The MAP faithfully reflects the duration as well as the the MAP is in part due to its smaller amplitude and in part configuration of the repolarization phases one through to the fact that the MAP electrode records the electrical three of the TAP [2,31].”
InfluentialSelf-citationShimizu, W., Ohe, T., Kurita, T., Kawade, M., Arakaki, Y., Aihara, N., Kamakura, S., Kamiya, T., & Shimomura, K. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00313-4 · Cited by 164
Mechano-electrical feedback in ventricular myocardium
FRANZ, M. (1996) · Cardiovascular Research · doi:10.1016/0008-6363(96)00074-0 · Cited by 159
Self-citationBen-David, J., & Zipes, D. P. (1988) · Circulation · doi:10.1161/01.cir.78.5.1241 · Cited by 155
Antiarrhythmic agents: modulated receptor applications.
Hondeghem, L. M. (1987) · Circulation · doi:10.1161/01.cir.75.3.514 · Cited by 149
Distribution of M Cells in the Canine Ventricle
Sicouri, S., Fish, J. M., & Antzelevitch, C. N. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01121.x · Cited by 135
Lerman, B. B., Burkhoff, D., Yue, D. T., Franz, M. R., & SAGAWA, K. (1985) · Journal of Clinical Investigation · doi:10.1172/jci112177 · Cited by 131
Self-citationFranz, M. R., CHIN, M. C., Sharkey, H., Griffin, J. C., & Scheinman, M. M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80336-5 · Cited by 123
Self-citationOn the Time‐Relations of the Excitatory Process in the Ventricle of the Heart of the Frog
Burdon-Sanderson, J. S. (1880) · The Journal of Physiology · doi:10.1113/jphysiol.1880.sp000070 · Cited by 120
Sicouri, S., & Antzelevitch, C. N. (1993) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1993.tb01211.x · Cited by 105
El‐Sherif, N., Bekheit, S.-S., & Henkin, R. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90082-x · Cited by 104
Localization of regional myocardial ischemia by recording of monophasic action potentials.
Franz, M. R., Flaherty, J. T., Platia, E. V., Bulkley, B. H., & Weisfeldt, M. L. (1984) · Circulation · doi:10.1161/01.cir.69.3.593 · Cited by 102
Self-citationFranz, M. R., & Costard‐Jäckle, A. (1988) · Circulation · doi:10.1161/01.cir.77.5.1177 · Cited by 101
Self-citationA Study on the Healing-over of Myocardial Cells of Toads
Mello, W. C. D., de Motta, G. E., & Chapeau, M. (1969) · Circulation Research · doi:10.1161/01.res.24.3.475 · Cited by 98
Electrophysiologic Characteristics of M Cells in the Canine Left Ventricular Free Wall
Sicouri, S., & Antzelevitch, C. (1995) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1995.tb00435.x · Cited by 97 · cited 1×
“Methods such different repolarization characteristics than either epicar- as cutting, stabbing or burning of a myocardial site were dial or endocardial cells [5], and these different charac- invented to produce monophasic ‘injury’ currents [8].”
Antzelevitch, C., & Moe, G. K. (1981) · Circulation Research · doi:10.1161/01.res.49.5.1129 · Cited by 89
Electrophysiologic Features of Torsades de Pointes: Insights from a New Isolated Rabbit Heart Model
Zabel, M., Hohnloser, S. H., BEHRENS, S., Li, Y., Woosley, R. L., & Franz, M. R. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01001.x · Cited by 89
Self-citationFranz, M. R. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01192.x · Cited by 86
Self-citationHabbab, M. A., & El-Sherie, N. (1990) · The American Journal of Medicine · doi:10.1016/0002-9343(90)90307-y · Cited by 76
Mello, W. C. D. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011627 · Cited by 75
Lee, R. J., Liem, L. B., Cohen, T. J., & Franz, M. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80281-5 · Cited by 59
Self-citationKurz, R. W., Mohabir, R., Ren, X.-D., & Franz, M. R. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.10.1410 · Cited by 57
Self-citationRole of M cells in acquired long QT syndrome, U waves, and torsade de pointes
Antzelevitch, C., Nesterenko, V. V., & Yan, G. (1995) · Journal of Electrocardiology · doi:10.1016/s0022-0736(95)80038-7 · Cited by 53 · cited 1×
“In ̈ teristics have been found to be important for the develop- 1934, Schutz [9] introduced the suction electrode for ment of torsade de pointes arrhythmias [6].”
Shimizu, W., Ohe, T., Kurita, T., TOKUDA, T., & Shimomura, K. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01183.x · Cited by 48
Franz, M. R., Kirchhof, P. F., Fabritz, L., & Zabel, M. (1995) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1995.tb06988.x · Cited by 46
Self-citationOlsson, S. B. (1972) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1972.tb00030.x · Cited by 44
Local Capture by Atrial Pacing in Spontaneous Chronic Atrial Fibrillation
Pandozi, C., Bianconi, L., Villani, M., Castro, A., Altamura, G., Toscano, S., Jesi, A. P., Gentilucci, G., Ammirati, F., Bianco, F. L., et al. (1997) · Circulation · doi:10.1161/01.cir.95.10.2416 · Cited by 44
Intracardiac Recording of Monophasic Action Potentials in the Human Heart
Korsgren, M., Leskinen, E., Sjöstrand, U. H., & Varnauskas, E. (1966) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365516609103922 · Cited by 42 · cited 1×
“[10] attempts to review the available information on the MAP used a suction electrode catheter in a patient and recorded, genesis and its particular recording modes.”
Pf, K., Fabritz, L., Zabel, M., & Franz, M. R. (1996) · PubMed · Cited by 40
Self-citationCostard‐Jäckle, A., Liem, L. B., & Franz, M. R. (1989) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-198912000-00003 · Cited by 35
Self-citationStambler, B., Wood, M., & Ellenbogen, K. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00459-9 · Cited by 33
Schaefer, H. E., Peña, A., & Schölmerich, P. (1943) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf01753348 · Cited by 32
MONOPHASIC ACTION POTENTIALS FROM RIGHT ATRIAL MUSCLE RECORDED DURING HEART CATHETERIZATION
Olsson, S. B. (1971) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1971.tb07445.x · Cited by 26
Tande, P. M., Mortensen, E. S., & Refsum, H. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.5.h1387 · Cited by 24
Shock‐Induced Dispersion of Ventricular Repolarization:
Behrens, S., Li, C., Fabritz, L., Kirchhof, P. F., & Franz, M. R. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb00623.x · Cited by 18
Self-citationElectrical Characteristics of Injury Potentials
Cranefield, P. F., Eyster, J. A. E., & Gilson, W. E. (1951) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1951.167.2.450 · Cited by 17
Kirchhof, P. F., Fabritz, L., Behrens, S., & Franz, M. R. (1997) · Basic Research in Cardiology · doi:10.1007/bf00803755 · Cited by 16
Self-citationClinical Application of a Microcomputer System for Analysis of Monophasic Action Potentials
Yuan, S., Wohlfart, B., Olsson, S. B., & Blomström‐Lundqvist, C. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03331.x · Cited by 11
Cited by
Effect of Adrenergic Stimulation on Action Potential Duration Restitution in Humans
Taggart, P., Sutton, P., Chalabi, Z., Boyett, M. R., Simon, R., Elliott, D., & Gill, J. S. (2003) · Circulation · doi:10.1161/01.cir.0000044941.13346.74 · Cited by 184
Brisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/521 · Cited by 6
Metadata
- Authors
- Franz, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-01-01
- Volume
- 41
- Issue
- 1
- Pages
- 25-40
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2129124697
- Cited by
- 173
- References
- 53
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.