Cited by 33Corneal surgery and disordersForce Microscopy Techniques and ApplicationsCollagen: Extraction and Characterization

Observation of human corneal and scleral collagen fibrils by atomic force microscopy

Yamamoto, S·2002·Japanese Journal of Ophthalmology

Abstract

Purpose We attempted to analyze the three-dimensional ultrastructure of human corneal and scleral collagen fibrils with an atomic force microscope (AFM). Methods A normal eye removed from a 66-year-old male patient during therapy was used in this study. Suspended corneal and scleral collagen fibrils were individually attached to glass slides by centrifugation. These collagen fibrils were air-dried and observed with a noncontact-mode AFM in air. Results AFM imaging provided information on the surface topography of both corneal and scleral collagen fibrils. The corneal collagen fibrils had a height of 11.9 +/- 1.0 nm (mean +/- SD) and scleral fibrils a height of 82.5 +/- 35.6 nm. A periodic banding pattern of grooves and ridges was clearly found on both types of fibrils; the D-periodicity and the groove depth were 65.7 +/- 0.8 nm and 1.46 +/- 0.50 nm in the corneal fibrils, and 67.3 +/- 1.1 nm and 6.16 +/- 1.23 nm in the scleral fibrils. Conclusions Surface topographic images of human corneal and scleral collagen fibrils were clearly obtained with the AFM. This technique provides quantitative information on the surface morphology of the collagen fibrils at high resolution.

Integrity signals

Registry

Crossref · 10.1016/s0021-5155(02)00558-0

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • When proteoglycans have their attached glycosaminoglycans removed enzymatically, the surface gap depth increases to about 1.5 nm.

    “When proteoglycans have their attached glycosaminoglycans removed enzymatically, the surface gap depth increases to about 1.5 nm (Yamamoto et al., 2002).”

    From Corneal structure and transparency (2015) · cites this paper as Yamamoto et al., 2002

Cited by

Sorted by citations

Authors
Yamamoto, S.
Affiliations
Niigata University (JP)
Corresponding author
Yamamoto, S
Venue
Japanese Journal of Ophthalmology
Publisher
Elsevier BV
Published
2002-10
Volume
46
Issue
5
Pages
496-501
ISSN
0021-5155 (ISSN-L)
OpenAlex
W4248439437
Cited by
33
References
0
Citations by year
2019: 1 · 2016: 3 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 3
FWCI
1.73
Type
journal article
Language
en
Open access
closed
Locations
Japanese Journal of Ophthalmology (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
Keywords
corneal collagen fibrils, collagen fibril ultrastructure, surface topography, non-contact atomic force microscopy, human cornea, human sclera

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review