The DOI matches its Crossref record.
A gas-liquid solid phase peptide and protein sequenator.
Open accessAbstract
A new miniaturized protein and peptide sequenator has been constructed which uses gas phase reagents at the coupling and cleavage steps of the Edman degradation. The sample is embedded in a matrix of Polybrene dried onto a porous glass fiber disc located in a small cartridge-style reaction cell. The protein or peptide, though not covalently attached to the support, is essentially immobile throughout the degradative cycle, since only relatively apolar, liquid phase solvents pass through the cell. This instrument can give useful sequence data on as little as 5 pmol or protein, can perform extended sequence runs (greater than 30 residues) on subnanomole quantities of proteins purified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and can sequence hydrophobic peptides to completion. The sequenator is characterized by a high repetitive yield during the degradation, low reagent consumption, low maintenance requirements, and a degradative cycle time of only 50 min using a complete double cleavage program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Matsudaira, P. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)61070-1 · Cited by 4,950
The precursor of Alzheimer's disease amyloid A4 protein resembles a cell-surface receptor
Kang, J., Lemaire, H.-G., Unterbeck, A., Salbaum, J. M., Masters, C. L., Grzeschik, K.-H., Multhaup, G., Beyreuther, K., & Müller-Hill, B. (1987) · Nature · doi:10.1038/325733a0 · Cited by 4,619
Close similarity of epidermal growth factor receptor and v-erb-B oncogene protein sequences
Downward, J., Yarden, Y., Mayes, E., Scrace, G., Totty, N., Stockwell, P., Ullrich, A., Schlessinger, J., & Waterfield, M. D. (1984) · Nature · doi:10.1038/307521a0 · Cited by 2,516
Hirano, T., Yasukawa, K., Harada, H., Taga, T., Watanabe, Y., Matsuda, T., Kashiwamura, S.-I., Nakajima, K., Koyama, K., Iwamatsu, A., et al. (1986) · Nature · doi:10.1038/324073a0 · Cited by 2,139
Metadata
- Authors
- Hewick, R. M., Hunkapiller, M. W., Hood, L. E., & Dreyer, W. J.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1981-08
- Volume
- 256
- Issue
- 15
- Pages
- 7990-7997
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1600871831
- Cited by
- 2,218
- References
- 0
- FWCI
- 32.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A gas-liquid solid phase peptide and protein sequenator. https://app.cochat.ai/papers/10.1016/s0021-9258(18)43377-7
- The paper
- Hewick, R. M., Hunkapiller, M. W., Hood, L. E., & Dreyer, W. J. (1981). A gas-liquid solid phase peptide and protein sequenator. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)43377-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.