A gas-liquid solid phase peptide and protein sequenator.
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A new miniaturized protein and peptide sequenator has been constructed which uses gas phase reagents at the coupling and cleavage steps of the Edman degradation. The sample is embedded in a matrix of Polybrene dried onto a porous glass fiber disc located in a small cartridge-style reaction cell. The protein or peptide, though not covalently attached to the support, is essentially immobile throughout the degradative cycle, since only relatively apolar, liquid phase solvents pass through the cell. This instrument can give useful sequence data on as little as 5 pmol or protein, can perform extended sequence runs (greater than 30 residues) on subnanomole quantities of proteins purified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and can sequence hydrophobic peptides to completion. The sequenator is characterized by a high repetitive yield during the degradation, low reagent consumption, low maintenance requirements, and a degradative cycle time of only 50 min using a complete double cleavage program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Edman, P., & Begg, G. (1967) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1967.tb00047.x · Cited by 2,845
Polyquarternary amines prevent peptide loss from sequenators
Tarr, G. E., Beecher, J. F., Bell, M., & McKean, D. J. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90086-6 · Cited by 451
Application of sequenator analysis to the study of proteins
Hermodson, M. A., Ericsson, L. H., Titani, K., Neurath, H., & Walsh, K. A. (1972) · Biochemistry · doi:10.1021/bi00774a011 · Cited by 415
Application of 0.1 M quadrol to the microsequence of proteins and the sequence of tryptic peptides
Brauer, A. W., Margolies, M. N., & Haber, E. (1975) · Biochemistry · doi:10.1021/bi00684a036 · Cited by 393
Hunkapiller, M. W., & Hood, L. E. (1978) · Biochemistry · doi:10.1021/bi00604a016 · Cited by 383
Self-citationSood, A. K., Pereira, D., & Weissman, S. M. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.1.616 · Cited by 363
Automated amino acid sequence of small peptides utilizing Polybrene
Klapper, D. G., Wilde, C. E., & Capra, J. D. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90282-8 · Cited by 321
New Protein Sequenator with Increased Sensitivity
Hunkapiller, M. W., & Hood, L. E. (1980) · Science · doi:10.1126/science.7352258 · Cited by 158
Self-citationWittmann‐Liebold, B., Graffunder, H., & Kohls, H. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90117-2 · Cited by 123
Cited by
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Matsudaira, P. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)61070-1 · Cited by 4,950
The precursor of Alzheimer's disease amyloid A4 protein resembles a cell-surface receptor
Kang, J., Lemaire, H.-G., Unterbeck, A., Salbaum, J. M., Masters, C. L., Grzeschik, K.-H., Multhaup, G., Beyreuther, K., & Müller-Hill, B. (1987) · Nature · doi:10.1038/325733a0 · Cited by 4,619
A novel heterodimeric cysteine protease is required for interleukin-1βprocessing in monocytes
Thornberry, N. A., Bull, H. G., Calaycay, J. R., Chapman, K. T., Howard, A. D., Kostura, M. J., Miller, D. K., Molineaux, S. M., Weidner, J. R., Aunins, J., et al. (1992) · Nature · doi:10.1038/356768a0 · Cited by 2,572
Close similarity of epidermal growth factor receptor and v-erb-B oncogene protein sequences
Downward, J., Yarden, Y., Mayes, E., Scrace, G., Totty, N., Stockwell, P., Ullrich, A., Schlessinger, J., & Waterfield, M. D. (1984) · Nature · doi:10.1038/307521a0 · Cited by 2,516
Metadata
- Authors
- Hewick, R. M., Hunkapiller, M. W., Hood, L. E., & Dreyer, W. J.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1981-08
- Volume
- 256
- Issue
- 15
- Pages
- 7990-7997
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1600871831
- Cited by
- 2,218
- References
- 10
- FWCI
- 32.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.