An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
An optical method for measuring oxygen concentrations in aqueous solutions is described. This method is based upon the oxygen-dependent quenching of phosphorescence. Phosphorescence excitation and emission spectra and lifetimes of some of the probe molecules suitable for measurement of oxygen in aqueous solutions are given. The probes include fluorescein derivatives, 4'5'-diiodofluorescein, eosin Y, 5(and 6)-carboxyeosin, erythrosin, and 5(and 6)-carboxyerythrosin as well as the Zn(II), Y(III), Sn(IV), Lu(III), and Pd(II) derivatives of meso-tetra-(4-sulfonatophenyl)-porphine, meso-tetra-(N-methyl-4-pyridyl)-porphine and coproporphyrin. The phosphorescence lifetimes of the given probes were found to depend upon the oxygen concentration by a simple Stern-Volmer relationship with a quenching constant of approximately 10(9) M-1 S-1. Binding of the molecules to bovine serum albumin decreased the quenching constant for oxygen by approximately an order of magnitude and also inhibited probe self-quenching, indicating that at the protein binding site the probes are somewhat protected from collision with quenchers. The use of this optical method for measuring oxygen is demonstrated for reactions catalyzed by glucose oxidase and by cytochrome c oxidase. It is shown that, using this method oxygen concentrations can be measured from approximately 250 microM (air saturation) down to the nanomolar range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Theory of the Kinetics of the Coagulation of Colloidal Solutions
Smoluchowski, M. (1917) · Zeitschrift für Physikalische Chemie · Cited by 2,814
On the preparation of metalloporphyrins
Adler, A. D., Longo, F. R., Kampas, F., & Kim, J. (1970) · Journal of Inorganic and Nuclear Chemistry · doi:10.1016/0022-1902(70)80535-8 · Cited by 1,761
INTRACELLULAR DISTRIBUTION OF ENZYMES
Schneider, W. C. (1948) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)51025-5 · Cited by 1,095
Porphyrin localization and treatment of tumors
Land, E. J. (1985) · British Journal of Cancer · doi:10.1038/bjc.1985.213 · Cited by 635
The Use of a Derivative of Hematoporphyrin in Tumor Detection 23
(1961) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/26.1.1 · Cited by 628
Kinetics and Mechanism of Action of Glucose Oxidase
Gibson, Q. H., Swoboda, B. E. P., & Massey, V. (1964) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)91224-x · Cited by 536
Triplet-singlet emission in fluid solutions. Phosphorescence of eosin
Parker, C. A., & Hatchard, C. G. (1961) · Transactions of the Faraday Society · doi:10.1039/tf9615701894 · Cited by 476
Photophysical and redox properties of water-soluble porphyrins in aqueous media
Kalyanasundaram, K., & Neumann-Spallart, M. (1982) · The Journal of Physical Chemistry · doi:10.1021/j100223a022 · Cited by 420
Spectra of the Metallo-derivatives of α,β,γ,δ-Tetraphenylporphine
Dorough, G. D., Miller, J. R., & Huennekens, F. M. (1951) · Journal of the American Chemical Society · doi:10.1021/ja01153a085 · Cited by 352
PORPHYRIN PHOTOSENSITIZATION AND PHOTOTHERAPY
Moan, J. (1986) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1986.tb05647.x · Cited by 295
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Helmlinger, G., Yuan, F., Dellian, M., & Jain, R. K. (1997) · Nature Medicine · doi:10.1038/nm0297-177 · Cited by 1,628
Singlet oxygen: there is indeed something new under the sun
Ogilby, P. R. (2010) · Chemical Society Reviews · doi:10.1039/b926014p · Cited by 1,266
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
“Oxygen is not consumed during the reaction, so a continuous readout of tissue pO2 can be obtained [24].”
BackgroundQUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Direct measurement of local oxygen concentration in the bone marrow of live animals
Spencer, J. A., Ferraro, F., Roussakis, E., Klein, A., Wu, J., Runnels, J. M., Zaher, W., Mortensen, L. J., Alt, C., Turcotte, R., et al. (2014) · Nature · doi:10.1038/nature13034 · Cited by 1,167
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Tissue oxygen tension and brain sensitivity to hypoxia
Erecińska, M., & Silver, I. A. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00306-1 · Cited by 615
Molecular Interactions in Organic Nanoparticles for Phototheranostic Applications
Ng, K. K., & Zheng, G. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00140 · Cited by 609
Microcirculatory oxygenation and shunting in sepsis and shock
Ince, C., & Sinaasappel, M. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00031 · Cited by 542
Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
Rumsey, W., Vanderkooi, J., & Wilson, D. (1988) · Science · doi:10.1126/science.241.4873.1649 · Cited by 534
Self-citationSakadžić, S., Roussakis, E., Yaseen, M. A., Mandeville, E. T., Srinivasan, V. J., Arai, K., Ruvinskaya, S., Devor, A., Lo, E. H., Vinogradov, S. A., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1490 · Cited by 451
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Wilson, D. F., Rumsey, W. L., Green, T. J., & Vanderkooi, J. M. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)69126-4 · Cited by 387
Self-citationThe physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Microvascular and tissue oxygen distribution
Intaglietta, M. (1996) · Cardiovascular Research · doi:10.1016/0008-6363(96)00110-1 · Cited by 293
Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288
Self-citationPhosphorescent Oxygen Sensor with Dendritic Protection and Two-Photon Absorbing Antenna
Briñas, R. P., Troxler, T., Hochstrasser, R. M., & Vinogradov, S. A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052947c · Cited by 267
Kajimura, M., Fukuda, R., Bateman, R. M., Yamamoto, T., & Suematsu, M. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2009.2657 · Cited by 266
Dinuclear metal complexes: multifunctional properties and applications
Li, G., Zhu, D., Wang, X., Su, Z., & Bryce, M. R. (2020) · Chemical Society Reviews · doi:10.1039/c8cs00660a · Cited by 227
Controlling the Response Characteristics of Luminescent Porphyrin Plastic Film Sensors for Oxygen
Mills, A., & Lepre, A. (1997) · Analytical Chemistry · doi:10.1021/ac970430g · Cited by 215
Rumsey, W. L., Schlosser, C., Nuutinen, E. M., Robiolio, M., & Wilson, D. F. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)55409-0 · Cited by 211
Self-citationRecent progress and applications for metallodendrimers
Hwang, S.-H., Shreiner, C. D., Moorefield, C. N., & Newkome, G. R. (2007) · New Journal of Chemistry · doi:10.1039/b612656c · Cited by 203
Joenje, H. (1989) · Mutation Research/DNAging · doi:10.1016/0921-8734(89)90001-5 · Cited by 197
Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors
Vinogradov, S. A., Lo, L. W., Jenkins, W. T., Evans, S. M., Koch, C., & Wilson, D. F. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79764-3 · Cited by 175
Self-citationMitochondrial PO2 measured by delayed fluorescence of endogenous protoporphyrin IX
Mik, E. G., Stap, J., Sinaasappel, M., Beek, J. F., Aten, J. A., van Leeuwen, T. G., & Ince, C. (2006) · Nature Methods · doi:10.1038/nmeth940 · Cited by 168
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“Unfortunately, this approach is susceptible to photobleaching, that decreases the intensity of luminescence after constant long-term excitation, to small movements in cells (133), to changes in optical geometry, optical properties and position of the sensor and to fluctuations in the light sources (122).”
BackgroundTao, Z., Raffel, R. A., Souid, A.-K., & Goodisman, J. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.11.071 · Cited by 96
“The reaction of glucose (C6H12O6) with O2 produces glucono-d-lactone (C6H10O6) and H2O2, as follows. glucose þ O2/glucono-d-lactone þ H2O2: In aqueous solutions, glucono-d-lactone (C6H10O6) reacts spontaneously with water to form gluconic acid (C6H12O7), so the overall reaction is C6H12O6 þ H2O þ O2/C6H12O7 þ H2O2: (1…”
BackgroundLocal Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Presley, T., Kuppusamy, P., Zweier, J. L., & Ilangovan, G. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.090175 · Cited by 34
Electron spin resonance microscopic imaging of oxygen concentration in cancer spheroids
Hashem, M., Weiler-Sagie, M., Kuppusamy, P., Neufeld, G., Neeman, M., & Blank, A. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.04.012 · Cited by 25
Hypoxia-inducible factor-1 is a determinant of lobular structure and oxygen consumption in the liver
Tsukada, K., Tajima, T., Hori, S., Matsuura, T., Johnson, R. S., Goda, N., & Suematsu, M. (2013) · Microcirculation · doi:10.1111/micc.12033 · Cited by 18
Metadata
- Authors
- Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1987-04
- Volume
- 262
- Issue
- 12
- Pages
- 5476-5482
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2097172537
- Cited by
- 592
- References
- 21
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.