CoChat

Purification and properties of human erythrocyte glutathione peroxidase.

Open access
Awasthi, Y C, Beutler, E, Srivastava, S K · 1975 · Journal of Biological Chemistry
Cited by 357

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Glutathione peroxidase has been purified to homogeneity from human erythrocytes. The purification steps involved ammonium sulfate precipitation of hemolysate, CM-cellulose (CM-52), DEAE-cellulose (DE52), Sephadex G-200, and DEAE-Sephadex column chromatography. In the last step, i.e. DEAE-Sephadex A-25 column chromatography, the enzyme was eluted in a major peak and tailing fraction. The major peak was found to be homogeneous on polyacrylamide disc electrophoresis and disignated as glutathione peroxidase A (GSH-Px A). The tail fraction, however, separated into two protein bands on polyacrylamide disc electrophoresis. One of the bands corresponded to GSH-Px A while the other band was slower moving and was designated as GSH-Px B. GSH-Px A and GSH-Px B had specific activity of 103 and 4 enzyme units per mg of protein, respectively. Antibodies raised against the homogeneous GSH-Px A have been found to cross-react with GSH-Px B. Both, GSH-Px A and B are selenoproteins. GSH-Px A has been found to contain 3.5 g atoms of selenium per mol of protein. Selenium content of GSH-Px B, however, could not be determined accurately due to insufficient material. The molecular weight of GSH-Px A as determined by the sedimentation equilibrium method is 95,000 plus or minus 3,000. On urea-sodium dodecyl sulfate-polyacrylamide disc electrophoresis GSH-Px A and B dissociate into single subunits. The molecular weight of the subunits of GSH-Px A is 23,000 and that of GSH-Px B is 47,000. Thus, it appears that GSH-Px A is a tetramer. Our results suggest that GSH-Px B is probably an altered form of the major component, GSH-Px A, or its precursor. The properties of GSH-Px A have been studied. The isoelectric pH was found to be 4.9 and the optimum pH for enzyme activity was 8.5. The energy of activation was 8.2 kcal. The Km of the enzyme for GSH was 4.1 mM while the Km for t-butyl hydroperoxide was 52 mu-M. The effect of sulfhydryl reagents and the metal ions on the enzyme was also studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(19)41289-1

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 357

Metadata

Authors
Awasthi, Y. C., Beutler, E., & Srivastava, S. K.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1975-07
Volume
250
Issue
13
Pages
5144-5149
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1484180915
Cited by
357
References
14
FWCI
12.14
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.