CoChat

Measurement and characterization of postischemic free radical generation in the isolated perfused heart

Open access
Zweier, J L, Kuppusamy, P, Williams, R, Rayburn, B K, Smith, D, Weisfeldt, M L, Flaherty, J T · 1989 · Journal of Biological Chemistry
Cited by 384

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Electron paramagnetic resonance spectroscopy has been applied to measure radical generation in the postischemic heart; however, there is controversy regarding the methods used and the conclusion as to whether radicals are generated. In order to resolve this controversy, direct and spin trapping measurements of the time course and mechanisms of radical generation were performed in isolated perfused rabbit hearts. In reperfused tissue, 3 prominent radical signals are observed: A, isotropic g = 2.004 suggestive of a semiquinone; B, anisotropic g parallel = 2.033 and g perpendicular = 2.005 suggestive of ROO.; and C, a triplet g = 2.000 and aN = 24 G suggestive of a nitrogen centered radical. B and C, however, are highly labile and disappear at temperatures probably encountered in some previous studies. In normally perfused hearts, A is observed with only small amounts of B and C. During ischemia, B and C increase reaching a maximum after 45 min while A decreases. On reflow with oxygenated perfusate all 3 signals increase. With varying duration of ischemia and reflow, peak signal intensities occurred after 15 s of reflow following 30 min of ischemia. Reperfusion with superoxide dismutase, deferoxamine, or mannitol abolished the reperfusion increase of B. Measurements performed with the spin trap 5,5'-dimethyl-1-pyrroline-N-oxide (DMPO) demonstrated a similar time course of radical generation with prominent DMPO-OH and DMPO-R signals peaking between 10 and 20 s of reflow. Superoxide dismutase and deferoxamine also quenched these signals. Thus, .O2- derived .OH, R., and ROO. radicals are generated in postischemic myocardium. While the experimental techniques used can result in loss of intrinsic radicals and generation of extraneous radicals, with proper care and controls valid measurements of free radicals in biological tissues can be performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(19)47240-2

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 384

Metadata

Authors
Zweier, J. L., Kuppusamy, P., Williams, R., Rayburn, B. K., Smith, D., Weisfeldt, M. L., & Flaherty, J. T.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1989-11
Volume
264
Issue
32
Pages
18890-18895
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1577460994
Cited by
384
References
20
FWCI
14.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.