High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 5×
“As Pugh (1973) had long ago noted, this assumption is probably inappropriate for trabecular tissue because cortical tissue is stronger in compression than tension (Reilly and Burstein, 1975), and similar behavior is likely for trabecular tissue (Keaveny, 1997; Morgan et al.”
BackgroundInfluentialThe mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Aging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationSilva, M. J., & Gibson, L. J. (1997) · Bone · doi:10.1016/s8756-3282(97)00100-2 · Cited by 355
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
Cited by
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“In these studies, the tissue modulus is determined from a ratio to apparent modulus calibrated against experimental results (141).”
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
“tension) in yield strains across all anatomic sites supports previous suggestions of a similarity in the yield strains between trabecular and cortical tissue (Keaveny, 1997; Niebur et al., 2000).”
ResultSelf-citationPistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
Cortical and Trabecular Load Sharing in the Human Vertebral Body
Eswaran, S. K., Gupta, A., Adams, M. F., & Keaveny, T. M. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2006.21.2.307 · Cited by 307
Self-citationYoung’s modulus of trabecular bone at the tissue level: A review
Wu, D., Isaksson, P., Ferguson, S. J., & Persson, C. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.001 · Cited by 263
Fracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260
“The first ''plastic-damage'' model (PD) used a Mises yield criterion, based on tissue material properties provided by Niebur et al. (2000).”
MethodTrabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur
Van Rietbergen, B., Huiskes, R., Eckstein, F., & Rüegsegger, P. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.10.1781 · Cited by 256
Trabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
“2MPa in tension (Niebur et al., 2000).”
BackgroundGuo, X. E., & Kim, C. H. (2002) · Bone · doi:10.1016/s8756-3282(01)00673-1 · Cited by 180
Homminga, J., McCreadie, B. R., Ciarelli, T. E., Weinans, H., Goldstein, S. A., & Huiskes, R. (2002) · Bone · doi:10.1016/s8756-3282(02)00693-2 · Cited by 177
Multi-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
“This is slightly higher than the 28% difference reported previously using micro-FE with the same 0.2% offset method to determine yield stress ( Niebur et al. 2000 ).”
MethodResultInfluentialLoad distribution in the healthy and osteoporotic human proximal femur during a fall to the side
Verhulp, E., van Rietbergen, B., & Huiskes, R. (2008) · Bone · doi:10.1016/j.bone.2007.08.039 · Cited by 174
“The yield load of each femur was estimated based on a bone–tissue maximal principal strain criterion [ 12 ].”
MethodChevalier, Y., Pahr, D., Allmer, H., Charlebois, M., & Zysset, P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.004 · Cited by 168
Zhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Damage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59
Self-citationLocal strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57
“It is noteworthy, that the value for the elastic modulus used by Chevalier et al., but also in other studies (Niebur et al., 2000; Bayraktar et al., 2004) was usually between 10 and 20 GPa and much higher compared to the value of 2.0 GPa that we measured for our samples.”
InfluentialGoda, I., & Ganghoffer, J.-F. (2015) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2014.10.007 · Cited by 51
Shi, X., Sherry Liu, X., Wang, X., Edward Guo, X., & Niebur, G. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.05.032 · Cited by 45
“This constitutive model results in correct prediction of the apparent level yield behavior (Niebur et al., 2000), and the strain limits in the tissue level constitutive model are consistent with the yield limits measured in cortical bone tissue (Bayraktar et al.”
MethodResultSelf-citation
Metadata
- Authors
- Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 33
- Issue
- 12
- Pages
- 1575-1583
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2095150495
- Cited by
- 431
- References
- 34
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.