Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 2×
“A direction dependency of ultimate strain was also found by Zysset and Curnier (1996), but not by Chang et al.”
BackgroundMisch, C. E., Qu, Z., & Bidez, M. W. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90437-8 · Cited by 509 · cited 1×
“The values for E-modulus and strength we found were considerably larger than the values reported for cancellous bone of the mandibular body (E-modulus: 56.0MPa, compressive strength: 3.9MPa; Misch et al., 1999).”
ResultEngineering Mechanics of Solids
Popov, E. P. (1998) · Medical Entomology and Zoology · Cited by 484
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377 · cited 1×
“Further, the compression tests between parallel plates generate systematical and random errors (Keaveny et al., 1997).”
BackgroundMechanical and textural properties of pelvic trabecular bone
Dalstra, M., Huiskes, R., Odgaard, A., & van Erning, L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90014-6 · Cited by 358
Self-citationLimitations of the continuum assumption in cancellous bone
Harrigan, T. P., Jasty, M., Mann, R. W., & Harris, W. H. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90257-6 · Cited by 305 · cited 1×
“Due to the specimens size the continuum assumption (Harrigan et al., 1988) is not valid, but at this point no alternative testing methods are available.”
BackgroundMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233 · cited 2×
“, underestimation of the modulus of elasticity (Linde et al., 1992).”
BackgroundHuman vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
Age variations in the properties of human tibial travecular bone
Ding, M. L., Dalstra, M., Danielsen, C. C., Kabel, J., Hvid, I., & Linde, F. (1997) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.79b6.7538 · Cited by 181
Self-citationConnectivity and the elastic properties of cancellous bone
Kabel, J., Odgaard, A., van Rietbergen, B., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(98)00164-1 · Cited by 168 · cited 1×
“Due to non-equal variance the mechanical parameters and the density parameters were logarithmically transformed and Pearson’s coefficients of correlation were calculated (Hodgskinson and Currey, 1990; Kabel et al., 1999).”
MethodSchaldach, M., & Furman, S. (1975) · Springer eBooks · doi:10.1007/978-3-642-66187-7 · Cited by 137
Elastic and viscoelastic properties of trabecular bone by a compression testing approach.
Linde, F. (1994) · PubMed · Cited by 121
A 3D damage model for trabecular bone based on fabric tensors
Zysset, P. K., & Curnier, A. (1996) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)80006-6 · Cited by 117
The Three-dimensional Cancellous Bone Architecture of the Human Mandibular Condyle
Giesen, E. B. W., & van Eijden, T. M. G. J. (2000) · Journal of Dental Research · doi:10.1177/00220345000790041101 · Cited by 105
Self-citationMechanical Properties of Trabecular Bone by a Non-Destructive Compression Testing Approach
Linde, F., Gøosthgen, C. B., Hvid, I., Pongsoipetch, B., & Bentzen, S. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_008_02 · Cited by 100
Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone
Hodgskinson, R., & Currey, J. D. (1990) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_227_02 · Cited by 88
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77 · cited 1×
“A direction dependency of ultimate strain was also found by Zysset and Curnier (1996), but not by Chang et al. (1999). The values for E-modulus and strength we found were considerably larger than the values reported for cancellous bone of the mandibular body (E-modulus: 56.”
ResultHongo, T., Yotsuya, H., Shibuya, K., et al. (1987) · PubMed · Cited by 3
Cited by
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Polymeric materials for bone and cartilage repair
Puppi, D., Chiellini, F., Piras, A. M., & Chiellini, E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.01.006 · Cited by 913
Hydrogels based on cellulose and chitin: fabrication, properties, and applications
Shen, X., Shamshina, J. L., Berton, P., Gurau, G., & Rogers, R. D. (2016) · Green Chemistry · doi:10.1039/c5gc02396c · Cited by 669
Wagoner Johnson, A. J., & Herschler, B. A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.012 · Cited by 635
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Metadata
- Authors
- Giesen, E. B. W., Ding, M., Dalstra, M., & van Eijden, T. M. G. J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-06
- Volume
- 34
- Issue
- 6
- Pages
- 799-803
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2025344532
- Cited by
- 201
- References
- 20
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.