Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797 · cited 5×
“An uncoupled deviatoric/dilational constitutive formulation has numerical advantages for simulating nearly incompressible material behavior with the FE method (Weiss et al., 1996), and the formulation is identical to the fully coupled strain energy in the limit of incompressibility or for an isochoric deformation (J 1…”
BackgroundMethodInfluentialSelf-citationMechanical characterization of skin—Finite deformations
Veronda, D. R., & Westmann, R. A. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90055-2 · Cited by 555 · cited 4×
“It was assumed that this stiffening behavior was due to the matrix strain energy, F1: After testing several forms for F1; a form introduced by Veronda and Westmann (Veronda and Westmann, 1970) was adopted: F1 ¼ C1½expðC2ð *I1 3ÞÞ 1 C1C2 2 ð *I2 3Þ: ð3Þ This strain energy is convex and exhibits physically reasonable be…”
MethodInfluentialWhirley, R. G., & Engelmann, B. E. (1993) · doi:10.2172/10139227 · Cited by 395
Material Characterization of Human Medial Collateral Ligament
Quapp, K. M., & Weiss, J. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834890 · Cited by 351 · cited 7×
“The values for the fiber family material coefficients, C3 C5; were taken from our previous work (C3 1⁄4 2:45; C4 1⁄4 30:6; C5 1⁄4 323:7 (Quapp and Weiss, 1998)), and C6 followed from the condition that the stress must be at least C0 continuous at l 1⁄4 l : The bulk modulus for each sample was chosen so that the ratio…”
BackgroundMethodResultInfluentialSelf-citationThe prime static stabilizer of the medical side of the knee.
Warren, L. E., Marshall, J. S., & Girgis, F. G. (1974) · PubMed · Cited by 285
Medial Collateral Ligament Injuries of the Knee: A Rationale for Treatment
FETTO, J. F., & MARSHALL, J. L. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197805000-00038 · Cited by 280 · cited 2×
“The medial collateral ligament (MCL) was chosen for study because it is one of the most frequently injured ligaments in the knee (Fetto and Marshall, 1978; Miyasaka et al., 1991), it plays a critical role in valgus and anterior–posterior knee stability and it provides an ideal ligamentous structure…”
BackgroundMethodViscoelastic shear properties of articular cartilage and the effects of glycosidase treatments
Zhu, W., Mow, V. C., Koob, T. J., & Eyre, D. R. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110602 · Cited by 280 · cited 1×
“It has been demonstrated that the resistance of cartilage to shear is highly dependent on the chemical status of proteoglycans, and shear modulus is greatly reduced when proteoglycans are degraded (Zhu et al., 1993).”
BackgroundThe Prime Static Stabilizer of the Medial Side of the Knee
WARREN, L. F., MARSHALL, J. L., & GIRGIS, F. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456040-00002 · Cited by 278 · cited 1×
“The distribution of stress and strain in knee ligaments is highly inhomogeneous under in vivo loading conditions (Gardiner et al., 2001; Hollis et al., 1991; Hull et al., 1996; Livesay et al., 1995, 1997; Markolf et al., 1993; Pfaeffle et al., 2000; Wang et al., 1973; Warren et al., 1974).”
BackgroundMedial collateral ligament injuries of the knee : a rationale for treatment
Fetto, J. L. (1978) · Clinical Orthopaedics and Related Research · Cited by 266
Puso, M. A., & Weiss, J. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834308 · Cited by 231
Self-citationA Structurally Based Stress-Stretch Relationship for Tendon and Ligament
Hurschler, C., Loitz-Ramage, B., & Vanderby, R. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798284 · Cited by 209 · cited 1×
“Transverse isotropy has been used successfully to describe ligament material symmetry (Hannafin and Arnoczky, 1994; Hirokawa and Tsuruno, 2000; Hurschler et al., 1997; Kohles et al., 1997; Lanir, 1980; Puso and Weiss, 1998; Simbeya et al., 1992; Weiss et al., 1996).”
MethodDanto, M. I., & Woo, S. L. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110108 · Cited by 193 · cited 1×
“When ligament is subjected to tensile testing at different strain rates, it exhibits some strain-rate dependence and less drop in stress during relaxation as compared to the shear loading (Danto and Woo, 1993).”
BackgroundPhysically based strain invariant set for materials exhibiting transversely isotropic behavior
Criscione, J. C., Douglas, A. S., & Hunter, W. C. (2001) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(00)00047-8 · Cited by 178 · cited 1×
“Criscione et al. (2001) reported on the development of a new, physically motivated set of invariants for describing transversely isotropic hyperelastic materials, and one of the invariants is directly proportional to shear strain.”
BackgroundHollis, J. M., Takai, S., Adams, D. J., Horibe, S., & Woo, S. L.-Y. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2891236 · Cited by 177 · cited 1×
“The distribution of stress and strain in knee ligaments is highly inhomogeneous under in vivo loading conditions (Gardiner et al., 2001; Hollis et al., 1991; Hull et al., 1996; Livesay et al., 1995, 1997; Markolf et al., 1993; Pfaeffle et al., 2000; Wang et al., 1973; Warren et al., 1974).”
BackgroundStrain in the Human Medial Collateral Ligament During Valgus Loading of the Knee
Gardiner, J. C., Weiss, J. A., & Rosenberg, T. D. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200110000-00031 · Cited by 167 · cited 1×
“The distribution of stress and strain in knee ligaments is highly inhomogeneous under in vivo loading conditions (Gardiner et al., 2001; Hollis et al., 1991; Hull et al., 1996; Livesay et al., 1995, 1997; Markolf et al., 1993; Pfaeffle et al., 2000; Wang et al., 1973; Warren et al., 1974).”
BackgroundSelf-citationThe effects of flexion and rotation on the length patterns of the ligaments of the knee
Wang, C.-J., Walker, P. S., & Wolf, B. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90016-x · Cited by 161 · cited 1×
“The distribution of stress and strain in knee ligaments is highly inhomogeneous under in vivo loading conditions (Gardiner et al., 2001; Hollis et al., 1991; Hull et al., 1996; Livesay et al., 1995, 1997; Markolf et al., 1993; Pfaeffle et al., 2000; Wang et al., 1973; Warren et al., 1974).”
BackgroundLivesay, G. A., Fujie, H., Kashiwaguchi, S., Morrow, D. A., Fu, F. H., & Woo, S. L. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584446 · Cited by 155
Hannafin, J. A., & ARNOCZKY, S. P. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120307 · Cited by 149 · cited 1×
“Transverse isotropy has been used successfully to describe ligament material symmetry (Hannafin and Arnoczky, 1994; Hirokawa and Tsuruno, 2000; Hurschler et al., 1997; Kohles et al., 1997; Lanir, 1980; Puso and Weiss, 1998; Simbeya et al., 1992; Weiss et al., 1996).”
MethodFrank, C., McDonald, D., Wilson, J., Eyre, D., & Shrive, N. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130203 · Cited by 127 · cited 2×
“Both hydroxyproline crosslink density (Frank et al., 1995; Woo et al., 1997) and hydroxypyridinium crosslink density (Ng et al., 1996; Salehpour et al., 1995) are positively correlated with modulus in ligaments and tendons.”
BackgroundHIROKAWA, S., & Tsuruno, R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00073-7 · Cited by 121 · cited 1×
“Transverse isotropy has been used successfully to describe ligament material symmetry (Hannafin and Arnoczky, 1994; Hirokawa and Tsuruno, 2000; Hurschler et al., 1997; Kohles et al., 1997; Lanir, 1980; Puso and Weiss, 1998; Simbeya et al., 1992; Weiss et al., 1996).”
MethodStrain in the medial collateral ligament of the human knee under single and combined loads
Hull, M. L., Berns, G. S., Varma, H., & Patterson, H. A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00046-1 · Cited by 102 · cited 1×
“The distribution of stress and strain in knee ligaments is highly inhomogeneous under in vivo loading conditions (Gardiner et al., 2001; Hollis et al., 1991; Hull et al., 1996; Livesay et al., 1995, 1997; Markolf et al., 1993; Pfaeffle et al., 2000; Wang et al., 1973; Warren et al., 1974).”
BackgroundNg, G. Y. F., Oakes, B. W., Deacon, O. W., McLean, I. D., & Eyre, D. R. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140602 · Cited by 78 · cited 2×
“, 1997) and hydroxypyridinium crosslink density (Ng et al., 1996; Salehpour et al., 1995) are positively correlated with modulus in ligaments and tendons.”
BackgroundEarly medial collateral ligament scars have inferior creep behaviour
Thornton, G. M., Leask, G. P., Shrive, N. G., & Frank, C. B. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180211 · Cited by 76 · cited 1×
“There is some evidence that crosslink density influences the viscoelasticity of healing ligament (Thornton et al., 2000), and thus crosslinking may govern both the quasi-static and viscoelastic response of ligament to shear.”
BackgroundSimple Shear Testing of Parallel-Fibered Planar Soft Tissues
Gardiner, J. C., & Weiss, J. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1351891 · Cited by 76 · cited 14×
“Specimen dimensions and loading conditions were chosen based on a previous FE parameter study that assessed the sensitivity of the strain field to changes in specimen aspect ratio ( Gardiner and Weiss, 2001 ).”
BackgroundMethodInfluentialSelf-citationWoo, S. L., Niyibizi, C., Matyas, J. R., Kavalkovich, K. W., Weaver-Green, C., & Fox, R. J. (1997) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679709003997 · Cited by 55 · cited 1×
“Both hydroxyproline crosslink density (Frank et al., 1995; Woo et al., 1997) and hydroxypyridinium crosslink density (Ng et al., 1996; Salehpour et al., 1995) are positively correlated with modulus in ligaments and tendons.”
BackgroundRecent advances in computer methods in biomechanics & biomedical engineering
Middleton, J., Pande, G. N., & Williams, K. R. (1992) · Medical Entomology and Zoology · Cited by 29
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Provenzano, P. P., & Vanderby, R. (2006) · Matrix Biology · doi:10.1016/j.matbio.2005.09.005 · Cited by 339
Lynch, H. A., Johannessen, W., Wu, J. P., Jawa, A., & Elliott, D. M. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1614819 · Cited by 272
Gardiner, J. C., & Weiss, J. A. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00113-x · Cited by 238
“The response of the strain energy function used in this study may be too stiff under shear loading as evidenced by large deformation simple shear loading of MCL samples [41].”
MethodSelf-citationVan Loocke, M., Lyons, C. G., & Simms, C. K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.007 · Cited by 228
“It can therefore be expected to display time and history-dependent behaviour resulting from interactions between these constituents as shown for soft tissues with similar structure such as ligaments and tendons (Abramowitch et al., 2004; Kwan et al., 1993; Weiss et al., 2002).”
Background
Metadata
- Authors
- Weiss, J. A., Gardiner, J. C., & Bonifasi-Lista, C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 35
- Issue
- 7
- Pages
- 943-950
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2159634163
- Cited by
- 210
- References
- 26
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.