A fabric-dependent fracture criterion for bone
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
A fracture criterion for bone tissue is proposed. Bone material is considered to be anisotropic and its properties are described by invoking the concept of directional variation of porosity. The fracture criterion is expressed as a scalar-valued function of the stress tensor and it incorporates an orientation-dependent distribution of compressive/tensile strength. The proposed mathematical framework is applied to a numerical analysis of fracture in the proximal femur due to a fall from standing height. The risk of fracture is assessed in the context of two different porosity distributions, simulating a healthy and an osteoporotic bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Early theoretical research on multiaxial failure in trabecular proposed fabric-based yield criteria (119, 120).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [120]
Citations
Cites
A General Theory of Strength for Anisotropic Materials
Tsai, S. W., & Wu, E. M. (1971) · Journal of Composite Materials · doi:10.1177/002199837100500106 · Cited by 3,393
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 1×
“In addition, previous studies (Reilly and Burstein, 1975; Burstein et al., 1976; Carter and Spengler, 1978; Torzilli et al., 1981; Stone et al., 1983; Keaveny et al., 1994) have clearly demonstrated that the mechanical behaviour is, in general, inelastic and the strength in tension is considerably lower than in compre…”
BackgroundRepresentations of the Rotation and Lorentz Groups and Their Applications.
Hermann, R., Gelfand, I. M., Minlos, R. A., & Shapiro, Z. Y. (1966) · The American Mathematical Monthly · doi:10.2307/2315370 · Cited by 783
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“Here, o is the density of the bone material (considered as orientation-dependent) and c is a constant, typically within the range 1)c)2 (Keller, 1994).”
BackgroundDistribution of directional data and fabric tensors
Ken-Ichi, K. (1984) · International Journal of Engineering Science · doi:10.1016/0020-7225(84)90090-9 · Cited by 663
Aging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603 · cited 1×
“The former de"nes the distribution of the mean path length between bone/marrow interfaces (Whitehouse, 1974; Harrigan and Mann, 1984), whereas the latter one speci"es for each point within the structure the local orientation of the solid volume.”
BackgroundThe quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579 · cited 1×
“The former de"nes the distribution of the mean path length between bone/marrow interfaces (Whitehouse, 1974; Harrigan and Mann, 1984), whereas the latter one speci"es for each point within the structure the local orientation of the solid volume.”
BackgroundAging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“It has also been applied to frictional materials [140] and bone tissue [42], with behave differently in terms of tension and compression.”
BackgroundMethodInfluentialAdvances in strength theories for materials under complex stress state in the 20th Century
Yu, M.-H. (2002) · Applied Mechanics Reviews · doi:10.1115/1.1472455 · Cited by 436
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
“Several authors addressed this issue, but many of them did not include a validation against experimental tests (Ford et al., 1996; Oden et al., 1999; Pietruszczak et al., 1999; Taddei et al., 2003), which is a mandatory step for clinical consideration (Viceconti et al.”
BackgroundMulti-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
“An alternative fabric based failure model was proposed which was insensitive to hydrostatic pressure ( Pietruszak et al. 1999 ).”
Lekszycki, T., & dell'Isola, F. (2012) · ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik · doi:10.1002/zamm.201100082 · Cited by 163
“in [40] where a fabric-dependent fracture criterion for bone is introduced.”
BackgroundModelling of bone fracture and strength at different length scales: a review
Sabet, F. A., Najafi, A. R., Hamed, E., & Jasiuk, I. (2015) · Interface Focus · doi:10.1098/rsfs.2015.0055 · Cited by 159
Parametric finite element analysis of verterbral bodies affected by tumors
Whyne, C. M., Hu, S. S., & Lotz, J. C. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00086-0 · Cited by 110
Hambli, R., Bettamer, A., & Allaoui, S. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.011 · Cited by 92
A Review of Head Injury and Finite Element Head Models
Tse, K. M., Lim, S. P., Tan, V. B. C., & Lee, H. P. (2015) · Journal of Engineering and Technology · Cited by 83
Madeo, A., Lekszycki, T., & dell’Isola, F. (2011) · Comptes Rendus Mécanique · doi:10.1016/j.crme.2011.07.004 · Cited by 81
“in [36] where a fabric-dependent fracture criterion for bone is introduced.”
BackgroundTrabelsi, N., & Yosibash, Z. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004180 · Cited by 73
Patient‐specific modelling of bone and bone‐implant systems: the challenges
Pankaj, P. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2536 · Cited by 71
“A range of anisotropic yield criteria, such as the Tsai–Wu [61, 62], Kelvin mode [63], cellularsolid [64] fabric-based [65,66] and fabric-based generalised Hill [67] have also been used for bone.”
BackgroundImaging Techniques for the Study of Food Microstructure: A Review
Falcone, P. M., Baiano, A., Conte, A., Mancini, L., Tromba, G., Zanini, F., & Nobile, M. A. D. (2006) · Advances in food and nutrition research · doi:10.1016/s1043-4526(06)51004-6 · Cited by 64
Finite Element Prediction of Proximal Femoral Fracture Patterns Under Different Loads
Gómez‐Benito, M. J., García‐Aznar, J. M., & Doblaré, M. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835347 · Cited by 62
Characterization of anisotropy in porous media by means of linear intercept measurements
Inglis, D., & Pietruszczak, S. (2003) · International Journal of Solids and Structures · doi:10.1016/s0020-7683(02)00595-4 · Cited by 62
“Several other measures, such as mean free path (Underwood, 1970), areal porosity distribution (Pietruszczak et al., 1999), etc.”
BackgroundSelf-citationTse, K. M., Tan, L. B., Lee, S. J., Lim, S. P., & Lee, H. P. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2609 · Cited by 51
“It is not possible to quantify the whole anisotropic structure of a bone organ with current techniques, although only one study with simple geometry [31] did include the anisotropic behavior of bone, but with a spatially constant anisotropy ratio [28].”
BackgroundRabiee, A. H., Tahmasbi, V., & Qasemi, M. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.105874 · Cited by 47
On Homogeneous and Localized Deformation in Water-Infiltrated Soils
Pietruszczak, S. (1999) · International Journal of Damage Mechanics · doi:10.1177/105678959900800302 · Cited by 47
Self-citationIsotropic Failure Criteria Are Not Appropriate for Anisotropic Fibrous Biological Tissues
Korenczuk, C. E., Votava, L. E., Dhume, R. Y., Kizilski, S. B., Brown, G. E., Narain, R., & Barocas, V. H. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4036316 · Cited by 47
Functionally heterogeneous porous scaffold design for tissue engineering
Khoda, B., & Koç, B. (2013) · Computer-Aided Design · doi:10.1016/j.cad.2013.05.005 · Cited by 45
On the modelling bone tissue fracture and healing of the bone tissue.
Doblaré, M., & García, J. M. (2003) · PubMed · Cited by 43
An Alternative Fabric-based Yield and Failure Criterion for Trabecular Bone
Zysset, P., & Rincón, L. (2006) · Mechanics of Biological Tissue · doi:10.1007/3-540-31184-x_33 · Cited by 39
Tse, K. M., Tan, L. B., Lee, S. J., Lim, S. P., & Lee, H. P. (2015) · Accident Analysis & Prevention · doi:10.1016/j.aap.2015.03.012 · Cited by 39
Computational analyses of small endosseous implants in osteoporotic bone
Wirth, A. J., Müller, R., & van Lenthe, H. (2010) · European Cells and Materials · doi:10.22203/ecm.v020a06 · Cited by 38
“It allows for a three-dimensional (3D) assessment of bone microstructure, with high accuracy and efficiency; some systems can even be used in vivo (Morgan and Bouxsein, 2005; Müller, 2002; Ploeg et al., 2004; Van Lenthe and Müller, 2006; Viceconti et al., 2004).”
MethodBoccaccio, A., Vena, P., Gastaldi, D., Franzoso, G., Pietrabissa, R., & Pappalettere, C. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim296 · Cited by 34
On the assessment of brittle–elastic cortical bone fracture in the distal radius
Pietruszczak, S., Gdela, K., Webber, C. E., & Inglis, D. (2006) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2006.06.005 · Cited by 26
Self-citationLeahy, P. D., Smith, B. S., Easton, K. L., Kawcak, C. E., Eickhoff, J. C., Shetye, S. S., & Puttlitz, C. M. (2010) · Bone · doi:10.1016/j.bone.2010.01.366 · Cited by 25
Fracture risk assessment in metastatic femurs: a patient-specific CT-based finite-element approach
Falcinelli, C., Martino, A. C. D., Gizzi, A., Vairo, G., & Denaro, V. (2019) · Meccanica · doi:10.1007/s11012-019-01097-x · Cited by 18
Miles, B., Kolos, E. C., Walter, W. L., Appleyard, R. C., Shi, A., Li, Q., & Ruys, A. J. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.03.012 · Cited by 17
Ojeda, C. (2009) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.1797 · Cited by 13
Process Plan for Multimaterial Heterogeneous Object in Additive Manufacturing
Khoda, B. (2014) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2014.0022 · Cited by 12
“17,18 These spatially distributed 3D features might represent uniform properties and their combination could capture the anisotropy in the bone ’ s structure.”
Kraiem, T., Barkaoui, A., Merzouki, T., & Chafra, M. (2020) · International Journal of Applied Mechanics · doi:10.1142/s1758825120500817 · Cited by 12
Micromechanics of Bone Modeled as a Composite Material
Jasiuk, I. (2017) · Springer eBooks · doi:10.1007/978-3-319-52794-9_10 · Cited by 10
Inelastic Analysis of Fracture Propagation in Distal Radius
Pietruszczak, S., & Gdela, K. (2009) · Journal of Applied Mechanics · doi:10.1115/1.3168595 · Cited by 9
Self-citationGasser, T. C., & Holzapfel, G. A. (2007) · IUTAM bookseries · doi:10.1007/978-1-4020-6530-9_12 · Cited by 9
Prediction of proximal femur fracture risk from DXA images based on novel fracture indexes
Zellagui, S., Hivet, A., Mouss, M. E., & Hambli, R. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2020.1833367 · Cited by 8
“…hip fracture risk are based on finite element (FE) models (Lotz et al. 1991a, 1991b; Ford and Keaveny 1996; Ford et al. 1996; Ota et al. 1999; Pietruszczak et al. 1999; Keyak and Falkinstein 2003; Taddei et al. 2006; Schileo et al. 2008; Dragomir-Daescu et al. 2011; Hambli et al. 2012;…”
BackgroundOn Colles’ Fracture: An Experimental Study Involving Structural and Material Testing
Gdela, K., Pietruszczak, S., Lade, P. V., & Tsopelas, P. C. (2008) · Journal of Applied Mechanics · doi:10.1115/1.2839902 · Cited by 8
Self-citationReliable Patient-Specific Simulations of the Femur
Yosibash, Z., & Trabelsi, N. (2011) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2011_89 · Cited by 8
“[27]).”
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Numerical analysis of hip fracture due to a sideways fall
Mohammadi, H., Pietruszczak, S., & Quenneville, C. E. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104283 · Cited by 7
Self-citationEngineering Microstructures to Evaluate and Replace Trabecular Bone
Hollister, S. J., Zysset, P. K., Guldberg, R. E., Chu, T. G., & Halloran, J. W. (2001) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0651-5_19 · Cited by 7
Bettamer, A. (2013) · theses.fr (ABES) · doi:10.70675/7d04b4bfza5b5z44dfz8f0cz49556bee8989 · Cited by 6
“…CT were developed in order to predict the human proximal failure under different conditions [Lotz et al., 1991, Ford et al., 1996, Ota et al., 1999, Pietruszczak et al., 1999, Testi et al., 1999, Keyak and Falkinstein, 2003, Schileo et al., 2008, Taddei et al., 2006, Dragomir-Daescu et al., 2011].”
BackgroundExperimental and analytical study of anisotropic strength properties of bovine cortical bone
Mohammadi, H., & Pietruszczak, S. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01319-2 · Cited by 6
Self-citationPredicting fracture of the femoral neck
Stepanskiy, L. G., & Seliktar, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.07.002 · Cited by 5
Virtual modelling the impact of torsional loading on osteoporotic vertebrae buckling
Chabarova, O., & Selivonec, J. (2024) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb-02392-2024-03 · Cited by 3
Reliability of Using Elastic Modulus for Non-Homogeneous Materials
Khan, R., & Mustansar, Z. (2016) · MATEC Web of Conferences · doi:10.1051/matecconf/20164909001 · Cited by 3
“904GPa [32] in the same axial direction using different bone-types.”
BackgroundOrthotropic reconstruction and characterization of bone tissues through a visco-plasto-damage model
Marangon, G., Fincato, R., Carniel, E. L., Toniolo, I., Berardo, A., & Mazzucco, G. (2025) · PLoS ONE · doi:10.1371/journal.pone.0335948 · Cited by 2
Öchsner, A. Ö., & Hosseini, S. M. H. (2010) · Wiley eBooks · doi:10.1002/9783527632732.ch6 · Cited by 2
Computational Analysis of Bone Fracture
Nicolella, D. P., & Bredbenner, T. L. (2014) · Springer eBooks · doi:10.1007/978-1-4939-1732-7_7 · Cited by 1
“On this basis, one could argue that relative fracture risk could be simply described in a relationship with bone density [8, 9], perhaps including the effects of the anisotropic microstructure of the bone [10, 11].”
BackgroundDubois, G. (2008) · theses.fr (ABES) · doi:10.70675/c0372420z90b2z4b0bz84e6zb600fca37e66 · Cited by 1
On incorporating bone microstructure in macro- nite-element models
Donaldson, F. E. (2011) · Edinburgh Research Archive (University of Edinburgh) · Cited by 1
The use of dual-energy X-ray absorptiometry images to evaluate the risk of bone fracture
Bettamer, A., Almhdie-Imjabbar, A., Hambli, R., Allaoui, S., Mahmud, M., & Jennane, R. (2015) · International Conference on Image Processing Theory, Tools and Applications (IPTA) · doi:10.1109/ipta.2015.7367155
“Over the past decades, a number of different 2D and 3D FE models based on DXA and CT were developed in order to predict the human proximal failure under different conditions [5-13].”
BackgroundMonotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
Ayagara, A. R. (2019) · theses.fr (ABES) · doi:10.70675/429ab026z48a8z4a6bz8e01zb25faacb1b3e
Behari, J. (2009) · Wiley eBooks · doi:10.1002/9780470824023.refs
Two tools for the science of material effort
Dudda, W., Nowak, Z., Ochrymiuk, T., & Badur, J. (2024) · Journal of Theoretical and Applied Mechanics/Mechanika Teoretyczna i Stosowana · doi:10.15632/jtam-pl/194319
“Some application of the ρ ( θ ) shape function has been applied to bone fracture mechanics by Pietruszczak et al .”
Remacha-Andrés, M., & Pérez Ansón, M. Á. (2016) · Zaguan (Universidad de Zaragoza)
Tse, K. M., Robinson, D. L., Franklyn, M., & Lee, P. V. S. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04347-8
Metadata
- Authors
- Pietruszczak, S., Inglis, D., & Pande, G. N.
- Affiliations
- McMaster University (CA)
- Swansea University (GB)
- Corresponding author
- Pietruszczak, S.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-10
- Volume
- 32
- Issue
- 10
- Pages
- 1071-1079
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2066503244
- Cited by
- 51
- References
- 34
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 6 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- tensile and compressive strength, stress tensor, hip fracture, fall from standing height, osteoporosis, fracture risk assessment
- MeSH terms
- Biomechanical Phenomena, Femoral Fractures, Femur, Humans, Models, Biological, Osteoporosis, Reference Values, Risk Factors, Tensile Strength, Anisotropy, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.