Cited by 39Elasticity and Material ModelingBone health and osteoporosis researchCellular and Composite Structures

An Alternative Fabric-based Yield and Failure Criterion for Trabecular Bone

Zysset, Ph., Rincón, L.·2006·Mechanics of Biological Tissue

Integrity signals

Registry

Crossref · 10.1007/3-540-31184-x_33

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • This barrier was subsequently overcome using numerical simulation, and there now exist several multiaxial yield criteria for trabecular bone.

    “This barrier was subsequently overcome using numerical simulation, as discussed in Section 2.2.9, below, and there now exist several multiaxial yield criteria for trabecular bone (see References 121–123 and references therein).”

    From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [121]

  • Casting the yield criterion in terms of strain, rather than stress, eliminates nearly all of the dependence of the yield surface on porosity and much of its dependence on fabric.

    “As several of these studies have found, casting the yield criterion in terms of strain, rather than stress, eliminates nearly all of the dependence of the yield surface on porosity and much of its dependence on fabric.”

    From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [121]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zysset, P., & Rincón, L.
Affiliations
Stryker (Switzerland) (CH)
Venue
Mechanics of Biological Tissue
Published
2006-06-02
Pages
457-470
OpenAlex
W31419221
Cited by
39
References
31
Citations by year
2026: 1 · 2025: 1 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2015: 2 · 2014: 4 · 2013: 6 · 2012: 6
FWCI
8.66
Type
book chapter
Language
en
Open access
closed
Locations
Springer eBooks (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
Keywords
trabecular bone, yield criterion, failure criteria, bone mechanical behavior, anisotropic porous media

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›