A fabric-dependent fracture criterion for bone
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
A fracture criterion for bone tissue is proposed. Bone material is considered to be anisotropic and its properties are described by invoking the concept of directional variation of porosity. The fracture criterion is expressed as a scalar-valued function of the stress tensor and it incorporates an orientation-dependent distribution of compressive/tensile strength. The proposed mathematical framework is applied to a numerical analysis of fracture in the proximal femur due to a fall from standing height. The risk of fracture is assessed in the context of two different porosity distributions, simulating a healthy and an osteoporotic bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Early theoretical research on multiaxial failure in trabecular proposed fabric-based yield criteria (119, 120).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [120]
Citations
Cites
A General Theory of Strength for Anisotropic Materials
Tsai, S. W., & Wu, E. M. (1971) · Journal of Composite Materials · doi:10.1177/002199837100500106 · Cited by 3,393
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 1×
“In addition, previous studies (Reilly and Burstein, 1975; Burstein et al., 1976; Carter and Spengler, 1978; Torzilli et al., 1981; Stone et al., 1983; Keaveny et al., 1994) have clearly demonstrated that the mechanical behaviour is, in general, inelastic and the strength in tension is considerably lower than in compre…”
BackgroundRepresentations of the Rotation and Lorentz Groups and Their Applications.
Hermann, R., Gelfand, I. M., Minlos, R. A., & Shapiro, Z. Y. (1966) · The American Mathematical Monthly · doi:10.2307/2315370 · Cited by 783
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 2×
“Here, o is the density of the bone material (considered as orientation-dependent) and c is a constant, typically within the range 1)c)2 (Keller, 1994).”
BackgroundDistribution of directional data and fabric tensors
Ken-Ichi, K. (1984) · International Journal of Engineering Science · doi:10.1016/0020-7225(84)90090-9 · Cited by 663
Aging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603 · cited 1×
“The former de"nes the distribution of the mean path length between bone/marrow interfaces (Whitehouse, 1974; Harrigan and Mann, 1984), whereas the latter one speci"es for each point within the structure the local orientation of the solid volume.”
BackgroundThe quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579 · cited 1×
“The former de"nes the distribution of the mean path length between bone/marrow interfaces (Whitehouse, 1974; Harrigan and Mann, 1984), whereas the latter one speci"es for each point within the structure the local orientation of the solid volume.”
BackgroundAging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Mechanical Properties and Composition of Cortical Bone
CARTER, D. R., & SPENGLER, D. M. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197809000-00041 · Cited by 407 · cited 2×
“In addition, previous studies (Reilly and Burstein, 1975; Burstein et al., 1976; Carter and Spengler, 1978; Torzilli et al., 1981; Stone et al., 1983; Keaveny et al., 1994) have clearly demonstrated that the mechanical behaviour is, in general, inelastic and the strength in tension is considerably lower than in compre…”
BackgroundMethodKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Abduction forces in the one-legged stance
McLeish, R. D., & Charnley, J. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90006-0 · Cited by 262
Walker, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)90000-4 · Cited by 250
An alternative model for anisotropic elasticity based on fabric tensors
Zysset, P. K., & Curnier, A. (1995) · Mechanics of Materials · doi:10.1016/0167-6636(95)00018-6 · Cited by 210 · cited 1×
“Following the work by Zysset and Curnier (1995), assume that the orthotropic elastic moduli are de"ned as”
BackgroundTelemeterized in vivo hip joint force data: A report on two patients after total hip surgery
Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., & Burstein, A. H. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090502 · Cited by 190
An elastoplastic constitutive model for concrete
Pietruszczak, S., Jiang, J., & Mirza, F. A. (1988) · International Journal of Solids and Structures · doi:10.1016/0020-7683(88)90018-2 · Cited by 163 · cited 2×
“Pietruszczak et al. / Journal of Biomechanics 32 (1999) 1071}1079”
BackgroundSelf-citationMultiaxial strength characteristics of trabecular bone
Stone, J. L., Beaupré, G. S., & Hayes, W. C. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90083-0 · Cited by 133
Estimation of structural anisotropy based on volume orientation. A new concept
Odgaard, A., Jensen, E. B., & Gundersen, H. J. G. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb02955.x · Cited by 132 · cited 1×
“, Zysset and Curnier, 1996; Cowin, 1989), volume orientation (Odgaard et al., 1990), etc.”
Constitutive laws for engineering materials: theory and application
Vardoulakis, I. (1987) · International Journal of Rock Mechanics and Mining Sciences & Geomechanics Abstracts · doi:10.1016/0148-9062(87)90869-2 · Cited by 127
A 3D damage model for trabecular bone based on fabric tensors
Zysset, P. K., & Curnier, A. (1996) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)80006-6 · Cited by 117
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895413 · Cited by 115
Fabric dependence of an anisotropic strength criterion
Cowin, S. C. (1986) · Mechanics of Materials · doi:10.1016/0167-6636(86)90022-0 · Cited by 87 · cited 3×
“, Cowin, 1989) is still too fragmentary. At the same time, however, the architecture of bone structure bears some analogy to that of a class of cemented granular mixtures. Recognizing this fact, it seems rational to adopt a functional form typically employed for brittle-plastic materials. One particular formulation, d…”
BackgroundResultInfluentialAnatomy of the abductor muscles of the hip as studied by computed tomography.
Clark, J. M., & Haynor, D. R. (1987) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198769070-00010 · Cited by 78
Structural Properties of Immature Canine Bone
Torzilli, P. A., Takebe, K., Burstein, A. H., & Heiple, K. G. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138286 · Cited by 71
Smith, L. D. (1953) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-195335020-00009 · Cited by 59
Errors Induced by Off-Axis Measurement of the Elastic Properties of Bone
Turner, C. H., & Cowin, S. C. (1988) · Journal of Biomechanical Engineering · doi:10.1115/1.3108433 · Cited by 56
Geometry of theories of strength
Malmeĭster, A. K. (1969) · Mechanics of Composite Materials · doi:10.1007/bf00860067 · Cited by 54
Automated Finite Element Analysis of Excised Human Femora Based on Precision-QCT
Merz, B., Niederer, P. F., Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796021 · Cited by 40
Description of anisotropic response of clays using a tensorial measure of structural disorder
Pietruszczak, S., & Krucinski, S. (1989) · Mechanics of Materials · doi:10.1016/0167-6636(89)90014-8 · Cited by 39
Self-citationOn inelastic behaviour of anisotropic frictional materials
Pietruszczak, S. (1999) · Mechanics of Cohesive-Frictional Materials · doi:10.1002/(sici)1099-1484(199905)4:3<281::aid-cfm63>3.0.co;2-m · Cited by 25 · cited 1×
“A mathematical formulation of this problem has been recently outlined by Pietruszczak (1998). In order to illustrate the e!ect of aging on the risk of fracture, the numerical analysis discussed above, has been repeated for the case of a 20% uniform increase in average porosity, simulating osteoporotic changes in an ag…”
MethodSelf-citationP026 Assessment of risk of fracture in osteoporotic bone
Pietruszczak, S., & Pande, G. N. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)80138-3 · Cited by 1
Self-citationTaylor, M., Tanner, K. E., Freeman, M. A. R., & Yettram, A. L. (1996) · ePrints Soton (University of Southampton) · Cited by 1
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“It has also been applied to frictional materials [140] and bone tissue [42], with behave differently in terms of tension and compression.”
BackgroundMethodInfluentialAdvances in strength theories for materials under complex stress state in the 20th Century
Yu, M.-H. (2002) · Applied Mechanics Reviews · doi:10.1115/1.1472455 · Cited by 436
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
“Several authors addressed this issue, but many of them did not include a validation against experimental tests (Ford et al., 1996; Oden et al., 1999; Pietruszczak et al., 1999; Taddei et al., 2003), which is a mandatory step for clinical consideration (Viceconti et al.”
BackgroundMulti-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
“An alternative fabric based failure model was proposed which was insensitive to hydrostatic pressure ( Pietruszak et al. 1999 ).”
Metadata
- Authors
- Pietruszczak, S., Inglis, D., & Pande, G. N.
- Affiliations
- McMaster University (CA)
- Swansea University (GB)
- Corresponding author
- Pietruszczak, S.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-10
- Volume
- 32
- Issue
- 10
- Pages
- 1071-1079
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2066503244
- Cited by
- 51
- References
- 34
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 6 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- tensile and compressive strength, stress tensor, hip fracture, fall from standing height, osteoporosis, fracture risk assessment
- MeSH terms
- Biomechanical Phenomena, Femoral Fractures, Femur, Humans, Models, Biological, Osteoporosis, Reference Values, Risk Factors, Tensile Strength, Anisotropy, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.