CoChat

Identification of plasma proteins adsorbed on hemodialysis tubing that promote Staphylococcus aureus adhesion

Open access
Francois, Patrice, Schrenzel, Jacques, Stoerman-Chopard, Catherine, Favre†, Herve, Herrmann, Mathias, Foster, Timothy J., Lew, Daniel P., Vaudaux, Pierre · 2000 · Journal of Laboratory and Clinical Medicine
Cited by 75

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Risk factors for Staphylococcus aureus infections in patients undergoing hemodialysis include underlying disease, material-induced host defects, and the presence of vascular access catheters. To determine the specific contribution of various potentially adsorbed plasma components in promoting S aureus adhesion to shunt tubing during chronic hemodialysis, we quantified their respective amounts by Western immunoblotting and densitometry and estimated their individual adhesion-promoting activities with specific adhesion-modified bacterial mutants. Fibrinogen, which was the only component consistently present in tubing protein extracts from all patients, was adsorbed in significantly higher amounts on predialyzer than on postdialyzer tubing segments. In contrast, fibronectin and von Willebrand factor were irregularly present in patients' tubing, whereas vitronectin or thrombospondin remained undetectable in all samples. The contribution of fibrinogen in promoting S aureus attachment to hemodialysis tubing was demonstrated by (1) the significantly lower adhesion of a cIfA mutant of strain Newman compared with its parent; (2) the increased attachment of strain 8325-4 after complementation with the cloned cIfA gene on the multicopy plasmid pCF4; and (3) the general tendency for strains Newman and 8325-4(pCF4) to express higher attachment on predialyzer compared with postdialyzer tubing segments in relationship with the higher content of fibrinogen on the former material. However, the specific S aureus attachment-promoting activity of both prefilter and postfilter tubing-adsorbed fibrinogen were much lower than that of the native in vitro-adsorbed protein and may reflect masking or inactivation of the in vivo-adsorbed protein by unknown mechanisms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-2143(00)70018-7

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Francois, P., Schrenzel, J., Stoerman-Chopard, C., Favre†, H., Herrmann, M., Foster, T. J., Lew, D. P., & Vaudaux, P.
Venue
Journal of Laboratory and Clinical Medicine
Publisher
Elsevier BV
Published
2000-01
Volume
135
Issue
1
Pages
32-42
ISSN
0022-2143 (ISSN-L)
OpenAlex
W2083100571
Cited by
75
References
3
FWCI
4.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.