Prospective observation of CAD/CAM titanium ceramic single crowns: A three-year follow up
The DOI matches its Crossref record; 43 of the 46 references it cites were found in a registry or an index.
Abstract
Statement of problem Computer-aided design/computer-aided manufacturing (CAD/CAM) titanium ceramic restorations were developed with the potential for replacing expensive, high noble metal ceramic restorations. However, there is a lack of information about the clinical performance of CAD/CAM titanium ceramic single crowns.Purpose The purpose of this study was to evaluate CAD/CAM titanium ceramic single crowns after 3 years in function.Material and methods A total of 41 crowns were fabricated for 21 patients. The titanium copings were CAD/CAM milled (Everest CAD/CAM system) with an even thickness of 0.5 mm, and low-fusing veneering porcelain (Vita Titanium Porcelain) was added incrementally. The crowns were cemented using zinc phosphate cement after confirming that there were no mechanical and biological complications. The patients were recalled at 12, 24, and 36 months after cementation to examine the presence of any complications and measure periodontal parameters such as probing depth (PD), bleeding on probing (BOP), and plaque index (PI). The success and survival rates were estimated using the Kaplan-Meier analysis.Results The success rate of CAD/CAM titanium ceramic crowns with regard to mechanical complications was 82.3% (95% confidence interval: 71.2% to 95.1%). The cumulative survival rate of the crowns was 94.9% (95% confidence interval: 88.3% to 100%) after 3 years. No biological complications were observed. At the end of the follow up, PD was 2.93 mm, percentile of surface with BOP was 29.2, and PI was 0.31.Conclusions The clinical performances of the CAD/CAM titanium ceramic crowns for 3 years were acceptable, with no biologic complications and a high cumulative survival rate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal Condition
Silness, J., & Löe, H. (1964) · Acta Odontologica Scandinavica · doi:10.3109/00016356408993968 · Cited by 7,932
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
Carranza's Clinical Periodontology
Newman, H. H. T. E. B. M. G. (2001) · Medical Entomology and Zoology · Cited by 837
Tan, K., Pjetursson, B. E., Lang, N. P., & Chan, E. S. Y. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01119.x · Cited by 769
Sailer, I., Pjetursson, B. E., Zwahlen, M., & Hämmerle, C. H. F. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01468.x · Cited by 724
Pjetursson, B. E., Tan, K., Lang, N. P., Brägger, U., Egger, M., & Zwahlen, M. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01117.x · Cited by 486
Titanium and titanium alloys as dental materials.
Lautenschlager, E. P., & Monaghan, P. (1993) · PubMed · Cited by 474
Pjetursson, B. E., Sailer, I., Zwahlen, M., & Hämmerle, C. H. F. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01467.x · Cited by 454
Periodontal probing: What does it mean?
Listgarten, M. A. (1980) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1980.tb01960.x · Cited by 435
Titanium for prosthodontic applications: a review of the literature.
Wang, R. R., & Fenton, A. H. (1996) · PubMed · Cited by 374
Research works printed but not linked: 1
- Persson, 1995, The accuracy of a high-precision digitizer for CAD/CAM of crowns, J Prosthet Dent, 74, 223, 10.1016/s0022-3913(05)80127-1 · DOI
Cited by
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0569 · Cited by 105
Clinical outcome of single porcelain-fused-to-zirconium dioxide crowns: A systematic review
Takeichi, T., Katsoulis, J., & Blatz, M. B. (2013) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.09.015 · Cited by 76
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12950 · Cited by 67
Revolutionizing Restorative Dentistry: An Overview
Prithviraj, D. R., Bhalla, H. K., Vashisht, R., Sounderraj, K., & Prithvi, S. (2014) · The Journal of Indian Prosthodontic Society · doi:10.1007/s13191-014-0351-5 · Cited by 49
“[11] evaluated CAD/CAM titanium ceramic single crowns after 3 years in function.”
MethodOzer, F., Mante, F. K., Chiche, G., Saleh, N., Takeichi, T., & Blatz, M. B. (2014) · PubMed · doi:10.3290/j.qi.a30768 · Cited by 45
Single crowns with CAD/CAM-fabricated copings from titanium: 6-year clinical results
Hey, J., Beuer, F., Bensel, T., & Boeckler, A. F. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.09.031 · Cited by 35
Self-citationTakeuchi, Y., Tanaka, M., Tanaka, J., Kamimoto, A., Furuchi, M., & Imai, H. (2019) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2019.07.008 · Cited by 29
Evaluating electrochemical behaviour of recrystallized titanium alloys in Ringer's solution
Mareci, D., Chelariu, R., Sutiman, D., Gordin, D. M., & Gloriant, T. (2011) · Materials and Corrosion · doi:10.1002/maco.201106185 · Cited by 25
Patel, D. R., O'Brien, T., Petrie, A., & Petridis, H. P. (2014) · Journal of Prosthodontics · doi:10.1111/jopr.12160 · Cited by 20
Influence of the processing route of porcelain/Ti–6Al–4V interfaces on shear bond strength
Toptan, F., Alves, A. C., Henriques, B. A. P. D. C., Souza, J. C. M., Coelho, R., Silva, F. S., Rocha, L. A., & Ariza, E. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.02.003 · Cited by 20
Bonding of Dental Ceramics to Titanium: Processing and Conditioning Aspects
Antanasova, M., & Jevnikar, P. (2016) · Current Oral Health Reports · doi:10.1007/s40496-016-0107-x · Cited by 20
Bond strength and interactions of machined titanium-based alloy with dental cements
Wadhwani, C. P. K., & Chung, K. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.015 · Cited by 19
“The clinical performances of both CAD/CAM titanium-ceramic crowns and fixed dental prostheses appear to be acceptable at 3 years with no apparent biologic complications and a high cumulative survival rate.(7,8) However, no guidelines exist as to the most appropriate luting agent to use.”
BackgroundCAD/CAM versus traditional indirect methods in the fabrication of inlays, onlays, and crowns
Oen, K. T., Veitz‐Keenan, A., Spivakovsky, S. E., Wong, Y. J., Bakarman, E. O., & Yip, J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011063 · Cited by 16
Effect of titanium preoxidation on wrought pure titanium to ceramic bond strength
Zhang, C.-C., Ye, J., Zhang, Y., Liao, J., & Li, B.-H. (2013) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(13)60025-6 · Cited by 16
Porcelain-titanium bonding with a newly introduced, commercially available system
Yang, J., Kelly, J. R., Bailey, O. G., & FISCHMAN, G. S. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.08.032 · Cited by 13
Espacio biológico y prótesis fija: Del concepto clásico a la aplicación tecnológica
Valdivieso, E. M., Palacios, M. A. A., & Morales, C. M. (2014) · Revista Estomatológica Herediana · doi:10.20453/reh.v22i2.135 · Cited by 11
Effect of Bonding Agent Application Method on Titanium‐Ceramic Bond Strength
Curtis, J., Dossett, J. M., Prihoda, T. J., & Teixeira, E. C. N. (2014) · Journal of Prosthodontics · doi:10.1111/jopr.12234 · Cited by 11
Donovan, T. E., Becker, W., Cagna, D. R., Hilton, T. J., & Rouse, J. S. (2010) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(10)60087-x · Cited by 10
Bonding of dental porcelain to non-cast titanium with different surface treatments
Lin, M.-C., Kuo-Lung, T. U. N. G., Lin, S.-C., & Huang, H. (2012) · Dental Materials Journal · doi:10.4012/dmj.2012-073 · Cited by 9
Ryniewicz, W., Bojko, Ł., & Ryniewicz, A. M. (2022) · Materials · doi:10.3390/ma15175835 · Cited by 9
Fukuyama, T., HAMANO, N., & Ino, S. (2016) · Dental Materials Journal · doi:10.4012/dmj.2015-290 · Cited by 9
Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces
Kumasaka, T., Ohno, A., Hori, N., Hoshi, N., Maruo, K., KUWABARA, A., Seimiya, K., Toyoda, M., & Kimoto, K. (2018) · Dental Materials Journal · doi:10.4012/dmj.2016-417 · Cited by 4
Dimofte, A.-R., Gheorghe, D. N., Popescu, D. M., Mitruț, I., Mărăşescu, P. C., Manolea, H. O., Boldeanu, M. V., & Șurlin, P. (2023) · Applied Sciences · doi:10.3390/app131910993 · Cited by 3
“In the presence of MC crowns, high GI values and up-regulated expression of CRP were detected, which clinically translated into exacerbation of periodontal inflammation in patients with periodontitis.”
Uz, N., İşisağ, Ö., Perçin, S., Aslantaş, K., & Kılıçlı, V. (2025) · BMC Oral Health · doi:10.1186/s12903-025-06133-9 · Cited by 3
“However, despite initially high expectations for milled Ti-ceramic systems, an increased risk of ceramic failure has been observed [25–29].”
Mareci, D., Strugaru, S. I., Iacoban, S., Bolat, G., & Munteanu, C. (2012) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-012-0330-0 · Cited by 3
The effect of thermal cycling on the shear bond strength of porcelain/Ti–6Al–4V interfaces
Sendão, I. A., Alves, A. C., Galo, R., Toptan, F., Silva, F. S., & Ariza, E. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.01.004 · Cited by 3
“…and some of its alloys have gained attention during the recent decades due to their excellent corrosion resistance, high strength-to-weight ratio, adequate mechanical properties and good biocompatibility (Bieniaś et al., 2009; Boeckler et al., 2009; Chakmakchi et al., 2009; Furuhashi et al., 2012).”
BackgroundBilkhair, A. (2014) · FreiDok plus (Universitätsbibliothek Freiburg) · Cited by 3
Medicina dentária digital – presente e futuro
Carvalho, B. J. P. D. (2013) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 3
Titanium - ceramic restoration: How to improve the binding between titanium and ceramic
Laksono, H. (2011) · Dental Journal (Majalah Kedokteran Gigi) · doi:10.20473/j.djmkg.v44.i1.p17-24 · Cited by 2
Gómez, J. R., Ortega, R. M., Parada, L. A., Camargo, E. D. J. L., Benavides, E. R. R., Muñoz, M. C. T., & Bautista, G. (2015) · Revista Salud Bosque · doi:10.18270/rsb.v1i2.91 · Cited by 2
Periodontal evaluation of restorative and prosthodontic margins
Cagidiaco, E. F. (2021) · Use Siena air (University of Siena) · doi:10.25434/edoardo-ferrari-cagidiaco_phd2021 · Cited by 2
Bond strengths of ceramics to biocompatible dental metals : substitutes for gold alloys
議곗쁺�썝 (2011) · YUHSpace (Yonsei University Medical Library) · Cited by 1
Mechanical Properties of Cast Commercially Pure Titanium Simulating Ceramic Firing Cycles
Fonseca, J. C., Spazzin, A. O., Naves, L. Z., Costa, A. R., Correr‐Sobrinho, L., & Henriques, G. E. P. (2012) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-1172
Graiff, L. (2016) · Padua@research (University of Padova)
Vokulova, Y. U. A., & Жулев, Е. Н. (2022) · Stomatology for all / International Dental Review · doi:10.35556/idr-2022-2(99)4-8
Influence of surface treatment and thermocycling on porcelain bonding to two forms of titanium
Radwan, M. M., Attia, M. A., ilhamy, T., & Badawy, M. (2023) · Egyptian Dental Journal /Egyptian Dental Journal · doi:10.21608/edj.2023.171597.2329
Cruz, P. G. D. V. S. (2013) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
Hamdi, R. N., Alwahab, Z. N., Li, Y., & Soliman, H. (2026) · AIP conference proceedings · doi:10.1063/5.0306686
Metadata
- Authors
- Boeckler, A. F., Lee, H., Stadler, A., & Setz, J. M.
- Affiliations
- Martin Luther University Halle-Wittenberg (DE)
- Louisiana State University (US)
- Corresponding author
- Boeckler, Arne F.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 102
- Issue
- 5
- Pages
- 290-297
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W1992260385
- Cited by
- 31
- References
- 46
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 2 · 2019: 1 · 2018: 3 · 2016: 3 · 2015: 2 · 2014: 7 · 2013: 3 · 2012: 3
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Prosthetic Dentistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
- Keywords
- single crowns, mechanical complications, periodontal parameters, zinc phosphate cement, clinical performance
- MeSH terms
- Dental Abutments, Adult, Aged, Cementation, Crowns, Dental Materials, Dental Plaque Index, Dental Porcelain, Dental Veneers, Female, Follow-Up Studies, Humans, Male, Middle Aged, Periodontal Index, Periodontal Pocket, Prospective Studies, Titanium, Zinc Phosphate Cement, Survival Analysis, Radiography, Bitewing, Treatment Outcome, Computer-Aided Design, Dental Prosthesis Design, Dental Prosthesis Repair, Tooth Preparation, Prosthodontic, Dental Restoration Failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.