CoChat

Prospective observation of CAD/CAM titanium ceramic single crowns: A three-year follow up

Boeckler, Arne F., Lee, Heeje, Stadler, Anke, Setz, Jürgen M. · 2009 · The Journal of Prosthetic Dentistry

The DOI matches its Crossref record; 43 of the 46 references it cites were found in a registry or an index.

Abstract

Statement of problem Computer-aided design/computer-aided manufacturing (CAD/CAM) titanium ceramic restorations were developed with the potential for replacing expensive, high noble metal ceramic restorations. However, there is a lack of information about the clinical performance of CAD/CAM titanium ceramic single crowns.Purpose The purpose of this study was to evaluate CAD/CAM titanium ceramic single crowns after 3 years in function.Material and methods A total of 41 crowns were fabricated for 21 patients. The titanium copings were CAD/CAM milled (Everest CAD/CAM system) with an even thickness of 0.5 mm, and low-fusing veneering porcelain (Vita Titanium Porcelain) was added incrementally. The crowns were cemented using zinc phosphate cement after confirming that there were no mechanical and biological complications. The patients were recalled at 12, 24, and 36 months after cementation to examine the presence of any complications and measure periodontal parameters such as probing depth (PD), bleeding on probing (BOP), and plaque index (PI). The success and survival rates were estimated using the Kaplan-Meier analysis.Results The success rate of CAD/CAM titanium ceramic crowns with regard to mechanical complications was 82.3% (95% confidence interval: 71.2% to 95.1%). The cumulative survival rate of the crowns was 94.9% (95% confidence interval: 88.3% to 100%) after 3 years. No biological complications were observed. At the end of the follow up, PD was 2.93 mm, percentile of surface with BOP was 29.2, and PI was 0.31.Conclusions The clinical performances of the CAD/CAM titanium ceramic crowns for 3 years were acceptable, with no biologic complications and a high cumulative survival rate.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0022-3913(09)60176-1

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 1

  1. Persson, 1995, The accuracy of a high-precision digitizer for CAD/CAM of crowns, J Prosthet Dent, 74, 223, 10.1016/s0022-3913(05)80127-1 · DOI

Cited by

See all 38

Metadata

Authors
Boeckler, A. F., Lee, H., Stadler, A., & Setz, J. M.
Affiliations
  • Martin Luther University Halle-Wittenberg (DE)
  • Louisiana State University (US)
Corresponding author
Boeckler, Arne F.
Venue
The Journal of Prosthetic Dentistry
Publisher
Elsevier BV
Published
2009-11
Volume
102
Issue
5
Pages
290-297
ISSN
0022-3913 (ISSN-L)
OpenAlex
W1992260385
Cited by
31
References
46
Citations by year
2026: 1 · 2025: 1 · 2023: 2 · 2022: 2 · 2019: 1 · 2018: 3 · 2016: 3 · 2015: 2 · 2014: 7 · 2013: 3 · 2012: 3
FWCI
2.45
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Journal of Prosthetic Dentistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
  • Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
Keywords
single crowns, mechanical complications, periodontal parameters, zinc phosphate cement, clinical performance
MeSH terms
Dental Abutments, Adult, Aged, Cementation, Crowns, Dental Materials, Dental Plaque Index, Dental Porcelain, Dental Veneers, Female, Follow-Up Studies, Humans, Male, Middle Aged, Periodontal Index, Periodontal Pocket, Prospective Studies, Titanium, Zinc Phosphate Cement, Survival Analysis, Radiography, Bitewing, Treatment Outcome, Computer-Aided Design, Dental Prosthesis Design, Dental Prosthesis Repair, Tooth Preparation, Prosthodontic, Dental Restoration Failure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.