Cited by 11Cellular Mechanics and InteractionsElectromagnetic Fields and Biological EffectsRheology and Fluid Dynamics Studies

Bioelectrorheological model of the cell. 2. Analysis of creep and its experimental verification

Fikus, Magdalena, Pawlowski, Piotr·1989·Journal of Theoretical Biology

Abstract

The electrorheological model of the cell proposed in Part 1 of this work was used to analyze changes in time of the shape of a cell acted on by a constant-amplitude external alternating electric field, with lossiness of the media taken into account. Shear stress in the cell membrane was determined. This model was then subjected to preliminary experimental verification using Neurospora crassa (slime) spheroplasts subjected to an external alternating electric field of constant frequency (3 MHz) and varying magnitude for different periods of time. Reversible viscoelastic cell deformation and fatigue (stiffening) of the material were observed. A satisfactory fit of the experimental data to Burgers' rheological model was found, and the values of the elastic moduli E1 = 9 X 10(2) N/m2, E2 = 2 X 10(2) N/m2 and viscosities eta 1 = 8 X 10(4) Ns/m2; eta 2 = 7 X 10(3) Ns/m2 were evaluated.

Integrity signals

Registry

Crossref · 10.1016/s0022-5193(89)80035-9

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In N. crassa, the bioelectrorheological model predicted changes in cell volume and surface caused by AEFs of 3000 kHz.

    “Further testing in N. crassa (mold cells) showed that the model was able to predict changes in cell volume and surface caused by AEFs of 3000 kHz [54].”

    From Permeabilizing Cell Membranes with Electric Fields (2021) · cites this paper as [54]

  • The bioelectrorheological model demonstrates the relationship between AEFs, shape deformations, and membrane destabilization, which can contribute to electroporation and other electric field-induced cell phenomena including electrofusion and electro-destruction.

    “The bioelectrorheological model of the cell was proposed and has been expanded upon through a series of manuscripts by Pawlowski et al. [40,53,54,55,56,57] (Figure 3B). This model demonstrates the relationship between AEFs, shape deformations, and membrane destabilization, which can contribute to electroporation and other electric field-induced cell phenomena including electrofusion and electro-d”

    From Permeabilizing Cell Membranes with Electric Fields (2021) · cites this paper as [54]

  • The bioelectrorheological model provides a possible explanation for the causes of electroporation by demonstrating the combined effects of heat energy and extensile stress leading to reversible cell membrane destabilization, which can directly result in electroporation.

    “Although the electric field strengths studied by Pawlowski and colleagues [40,53,54,55,56,57] were two orders of magnitude greater than that of TTFields, the bioelectrorheological model provides a possible explanation to the causes of electroporation by demonstrating the combined effects of heat energy and extensile stress leading to reversible cell membrane destabilization, which can directly”

    From Permeabilizing Cell Membranes with Electric Fields (2021) · cites this paper as [54]

  • Both DC and AC electroporation are believed to cause a dielectric breakdown of the cell; the oscillating nature of AC electroporation is thought to provoke structural fatigue of the membrane, comparable to the extensile stress proposed in the bioelectrorheological model.

    “Both types of electroporation are believed to cause a dielectric breakdown of the cell. However, the oscillating nature of AC electroporation is thought to provoke structural fatigue of the membrane [61], comparable to the extensile stress proposed in the bioelectrorheological model [40,53,54,55,56,57].”

    From Permeabilizing Cell Membranes with Electric Fields (2021) · cites this paper as [54]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fikus, M., & Pawlowski, P.
Affiliations
Institute of Biochemistry and Biophysics, Polish Academy of Sciences (PL)
Venue
Journal of Theoretical Biology
Publisher
Elsevier BV
Published
1989-04
Volume
137
Issue
4
Pages
365-373
ISSN
0022-5193 (ISSN-L)
OpenAlex
W2061373740
Cited by
11
References
10
Citations by year
2024: 1 · 2023: 1 · 2021: 1 · 2018: 1 · 2014: 1 · 2012: 1
FWCI
0.15
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Theoretical Biology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Rheology and Fluid Dynamics Studies
Keywords
viscoelasticity, AC electric field, Burgers model, elastic modulus, viscosity, cell deformation, lossy media
MeSH terms
Cell Membrane, Mathematics, Models, Biological, Neurospora crassa, Rheology, Stress, Mechanical

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review