Effective laboratory Evaluation of Thyroid Status
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This article focuses on recent developments in thyroid-related laboratory tests, including analytical methods, clinical utility, and limitations of TSH, FT4, T4, FT3/T3, thyroglobulin, and thyroid autoantibodies and the effective use of these tests in the diagnosis of various forms of hypothyroidism or hyperthyroidism, and the management of patients undergoing T4 replacement, T4 suppression, or antithyroid drug therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Free thyroxine in human serum: simplified measurement with the aid of magnesium precipitation.
Sterling, K., & Brenner, M. A. (1966) · Journal of Clinical Investigation · doi:10.1172/jci105320 · Cited by 411
Applications of a New Chemiluminometric Thyrotropin Assay to Subnormal Measurement*
SPENCER, C. A., LoPRESTI, J. S., PATEL, A., GUTTLER, R. B., EIGEN, A., SHEN, D., GRAY, D., & NICOLOFF, J. T. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-2-453 · Cited by 371
Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay.
Nelson, J. C., & Tomei, R. T. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.9.1733 · Cited by 128
LIMITATIONS OF A NEW FREE THYROXINE ASSAY (AMERLEX® FREE T4)
STOCKIGT, J. R., GARIS, M. D., CSICSMANN, J., BARLOW, J. W., WHITE, E. L., & HURLEY, D. M. (1981) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1981.tb00670.x · Cited by 84
ROSS, D. S., ARDISSON, L. J., & MESKELL, M. J. (1989) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-69-3-684 · Cited by 75
BYFIELD, P. G. H., LALLOZ, M. R. A., PEARCE, C. J., & HIMSWORTH, R. L. (1983) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1983.tb02991.x · Cited by 33
Cited by
Risk for fracture in women with low serum levels of thyroid-stimulating hormone
Bauer, D. C., Ettinger, B., Nevitt, M. C., Stone, K. L., & for the Study of Osteoporotic Fractures Research Group (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-7-200104030-00009 · Cited by 467
The sick euthyroid syndrome: changes in thyroid hormone serum parameters and hormone metabolism
Docter, R., Krenning, E. P., de Jong, M., & Hennemann, G. (1993) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1993.tb02401.x · Cited by 345
Desforges, J. F., & Woeber, K. A. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207093270206 · Cited by 266
Ferrous sulfate reduces thyroxine efficacy in patients with hypothyroidism
Campbell, N. R. C., Hasinoff, B. B., Stalts, H., Rao, B., & Wong, N. C. W. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-12-1010 · Cited by 231
“We did not measure free thyroxine because the current assays are insensitive compared with serum TSH in detecting hypothyroidism, and the clinical assays are associated with technical difficulties (14-17).”
Background
Metadata
- Authors
- Bayer, M. F.
- Venue
- Medical Clinics of North America
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 75
- Issue
- 1
- Pages
- 1-26
- ISSN
- 0025-7125 (ISSN-L)
- OpenAlex
- W154676760
- Cited by
- 34
- References
- 6
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective laboratory Evaluation of Thyroid Status. https://app.cochat.ai/papers/10.1016/s0025-7125(16)30469-2
- The paper
- Bayer, M. F. (1991). Effective laboratory Evaluation of Thyroid Status. Medical Clinics of North America. https://doi.org/10.1016/s0025-7125(16)30469-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.