The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sonographic measurement of uterine cervix at 18â22 weeks' gestation and the risk of preterm delivery
Abstract
OBJECTIVE: Premature delivery is difficult to predict and causes considerable neonatal morbidity and mortality. Despite much research, little progress has been made in timely identification of the mothers at risk. We examined the uterine cervix with ultrasonography to discover whether such a procedure would be helpful in determining which women will deliver prematurely. METHODS: We performed transvaginal ultrasound examinations in addition to routine transabdominal ultrasonography at 18 to 22 weeks' gestation in 3694 consecutive pregnant women with live singleton fetuses. We measured the length of the uterine cervix and evaluated the dilatation, if any, of the internal os. The results of cervical ultrasonography were not available to the clinicians. RESULTS: Spontaneous delivery occurred before 37 completed weeks in 88 women (2.4%) and before 35 weeks in 31 (0.8%). The relative risk of delivery before 35 weeks was 8 (95% confidence interval 3, 19) when the cervical length was 29 mm or shorter. When dilatation of the internal cervical os of 5 mm or greater was present, the relative risk of delivery before 35 weeks was 28 (95% confidence interval 12, 67). Either short cervix (29 mm or less) or dilatation of internal cervical os (5 mm or greater) was present in 3.6% of the population; this combination had a sensitivity of 29% in predicting delivery at earlier than 35 weeks. After adjusting for cervical dilatation and length by using multiple logistic regression, nulliparity also remained a risk factor for delivery before 35 weeks (odds ratio 3.6, 95% confidence interval 1.7, 7.5). CONCLUSION: Transvaginal ultrasonography performed as an addition to routine transabdominal ultrasonography at 18 to 22 weeks helps to identify many patients at significant risk for prematurity; however, low sensitivity and low positive predictive value limit its usefulness in screening low-risk obstetric populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iams, J. D., Johnson, F. F., Sonck, J., Sachs, L., Gebauer, C., & Samuels, P. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)91469-2 · Cited by 294
Cited by
Hassan, S. S., Romero, R., Vidyadhari, D., Fusey, S., Baxter, J. K., Khandelwal, M., Vijayaraghavan, J., Trivedi, Y., Soma‐Pillay, P., Sambarey, P., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.9017 · Cited by 923
Romero, R., Nicolaides, K., Conde-Agudelo, A., Tabor, A., O'Brien, J. M., Cetingoz, E., Da Fonseca, E., Creasy, G. W., Klein, K., Rode, L., et al. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.12.003 · Cited by 580
Mid-Trimester Endovaginal Sonography in Women at High Risk for Spontaneous Preterm Birth
Owen, J. (2001) · JAMA · doi:10.1001/jama.286.11.1340 · Cited by 509
Iams, J. D., Romero, R., Culhane, J. F., & Goldenberg, R. L. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60108-7 · Cited by 500
To, M. S., Alfirevic, Z., Heath, V. C., Cicero, S., Cacho, A. M., Williamson, P. R., & Nicolaides, K. H. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16351-4 · Cited by 419
Metadata
- Authors
- Taipale, P.
- Venue
- Obstetrics & Gynecology
- Published
- 1998-12
- Volume
- 92
- Issue
- 6
- Pages
- 902-907
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1984001966
- Cited by
- 197
- References
- 1
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sonographic measurement of uterine cervix at 18â22 weeks' gestation and the risk of preterm delivery. https://app.cochat.ai/papers/10.1016/s0029-7844(98)00346-9
- The paper
- Taipale, P. (1998). Sonographic measurement of uterine cervix at 18â22 weeks' gestation and the risk of preterm delivery. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(98)00346-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.