Comparative electrochemical inactivation of bacteria and bacteriophage
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of electroporation: A review
Weaver, J. C., & Chizmadzhev, Y. A. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05062-3 · Cited by 1,599 · cited 2×
“Death occurs due to either the formation of permanent pores and subsequent destabilization of the cell membrane, or loss of important cell components and destruction of chemical gradients via transport through transient pores [12].”
BackgroundKilling of microorganisms by pulsed electric fields
Grahl, T., & Märkl, H. (1996) · Applied Microbiology and Biotechnology · doi:10.1007/s002530050663 · Cited by 532
Mechanism of electrical enhancement of efficacy of antibiotics in killing biofilm bacteria
Costerton, J. W., Ellis, B., Lam, K., Johnson, F., & Khoury, A. E. (1994) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.38.12.2803 · Cited by 339 · cited 1×
“Current research indicates that antimicrobial agents and electric current act synergistically to inactivate microbes [10,11].”
BackgroundPrevention and Control of Bacterial Infections Associated with Medical Devices
KHOURY, A. E., LAM, K., ELLIS, B., & COSTERTON, J. W. (1992) · ASAIO Journal · doi:10.1097/00002480-199207000-00013 · Cited by 264 · cited 1×
“Current research indicates that antimicrobial agents and electric current act synergistically to inactivate microbes [10,11].”
BackgroundVenczel, L. V., Arrowood, M., Hurd, M., & Sobsey, M. D. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.4.1598-1601.1997 · Cited by 215 · cited 1×
“Electrolysis at the electrodes generates a variety of oxidants in the presence of oxygen, including hydrogen peroxide and ozone, as well as free chlorine and chlorine dioxide when chloride ions are present in the solution [1,8,9].”
BackgroundDisinfection of water by electrochemical treatment
Patermarakis, G., & Fountoukidis, E. (1990) · Water Research · doi:10.1016/0043-1354(90)90083-i · Cited by 166 · cited 5×
“5mA/cm(2) direct current density (125mA current) applied with 5 cm 5 cm titanium electrodes for 30min [5].”
BackgroundMethodInfluentialEffect of high-voltage electric pulses on yeast cells: factors influencing the killing efficiency
Gášková, D., Sigler, K., Janderová, B., & Plášek, J. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01892-1 · Cited by 123 · cited 1×
“Hence, the magnitude of the field needed to inactivate yeast cells is generally lower than that needed to inactivate bacteria [2].”
BackgroundWeaver, J. C., & POWELL, K. T. (1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2_7 · Cited by 81
Cited by
Recent developments of electro-oxidation in water treatment — A review
Särkkä, H., Bhatnagar, A., & Sillanpää, M. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.06.016 · Cited by 414
Electrochemical Alternatives for Drinking Water Disinfection
Martínez‐Huitle, C. A., & Brillas, E. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200703621 · Cited by 385
Electrochemical Multiwalled Carbon Nanotube Filter for Viral and Bacterial Removal and Inactivation
Vecitis, C. D., Schnoor, M. H., Rahaman, M. S., Schiffman, J. D., & Elimelech, M. (2011) · Environmental Science & Technology · doi:10.1021/es2000062 · Cited by 379
Electrified Membranes for Water Treatment Applications
Sun, M., Wang, X., Winter, L. R., Zhao, Y., Ma, W., Hedtke, T., Kim, J.-H., & Elimelech, M. (2021) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00015 · Cited by 320
Rahaman, M. S., Vecitis, C. D., & Elimelech, M. (2012) · Environmental Science & Technology · doi:10.1021/es203607d · Cited by 282
Metadata
- Authors
- Drees, K. P., Abbaszadegan, M., & Maier, R. M.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2003-05
- Volume
- 37
- Issue
- 10
- Pages
- 2291-2300
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2164052352
- Cited by
- 201
- References
- 8
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.