Effects of co-existing anions on fluoride removal in electrocoagulation (EC) process using aluminum electrodes
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and prevention of corrosion
Walker, R. (1993) · Materials & Design · doi:10.1016/0261-3069(93)90066-5 · Cited by 2,427
Principles and prevention of corrosion
Jones, D. A. (1991) · Cited by 2,104
Electrocoagulation (EC) — science and applications
Mollah, M. Y. A., Schennach, R., Parga, J. R., & Cocke, D. L. (2001) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(01)00176-5 · Cited by 1,506
HINGSTON, F. J., POSNER, A. M., & QUIRK, J. P. (1972) · Journal of Soil Science · doi:10.1111/j.1365-2389.1972.tb01652.x · Cited by 682
HINGSTON, F. J., ATKINSON, R. J., POSNER, A. M., & QUIRK, J. P. (1967) · Nature · doi:10.1038/2151459a0 · Cited by 464
Electrocoagulation of potable water
Vik, E. A., Carlson, D. A., Eikum, A. S., & Gjessing, E. T. (1984) · Water Research · doi:10.1016/0043-1354(84)90003-4 · Cited by 460
Mameri, N., Yeddou, A. R., Lounici, H., Belhocine, D., Grib, H., & BARIOU, B. (1998) · Water Research · doi:10.1016/s0043-1354(97)00357-6 · Cited by 403
Removal of nitrate from water by electroreduction and electrocoagulation
Koparal, A. S., & Öğütveren, Ü. B. (2002) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(01)00301-6 · Cited by 307
Precipitate flotation of fluoride-containing wastewater from a semiconductor manufacturer
Huang, C. (1999) · Water Research · doi:10.1016/s0043-1354(99)00065-2 · Cited by 230
ANION ADSORPTION BY GOETHITE AND GIBBSITE: II. DESORPTION OF ANIONS FROM HYDROUS OXIDE SURFACES
HINGSTON, F. J., POSNER, A. M., & QUIRK, J. P. (1974) · Journal of Soil Science · doi:10.1111/j.1365-2389.1974.tb01098.x · Cited by 229
Cited by
Recent developments in polysaccharide-based materials used as adsorbents in wastewater treatment
Crini, G. (2005) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.11.002 · Cited by 2,183
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
“The precipitate forms an insulating layer that decreases the current efficiency by increasing the potential between electrodes (Vepsalainen, 2012; Khandegar and Saroha, 2013; Hu et al., 2003; Trompette and Vergnes, 2009).”
BackgroundElectrocoagulation process in water treatment: A review of electrocoagulation modeling approaches
Hakizimana, J. N., Gourich, B., Chafi, M., Stiriba, Y., Vial, C., Drogui, P., & Naja, J. (2017) · Desalination · doi:10.1016/j.desal.2016.10.011 · Cited by 908
Garcia-Segura, S., Eiband, M. M. S. G., de Melo, J. V., & Martínez-Huitle, C. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.07.047 · Cited by 740
Review of pollutants removed by electrocoagulation and electrocoagulation/flotation processes
Emamjomeh, M. M., & Sivakumar, M. (2009) · Journal of Environmental Management · doi:10.1016/j.jenvman.2008.12.011 · Cited by 736
Electrocoagulation for the treatment of textile industry effluent – A review
Khandegar, V., & Saroha, A. K. (2013) · Journal of Environmental Management · doi:10.1016/j.jenvman.2013.06.043 · Cited by 669
Jadhav, S. V., Bringas, E., Yadav, G. D., Rathod, V. K., Ortiz, I., & Marathe, K. V. (2015) · Journal of Environmental Management · doi:10.1016/j.jenvman.2015.07.020 · Cited by 596
Behavior of aluminum electrodes in electrocoagulation process
Mouedhen, G., Feki, M., Wery, M. D. P., & Ayedi, H. F. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.04.090 · Cited by 507
Electrocoagulation applications for industrial wastewaters: a critical review
Kabdaşlı, I., Arslan-Alaton, I., Ölmez-Hancı, T., & Tünay, O. (2012) · Environmental Technology Reviews · doi:10.1080/21622515.2012.715390 · Cited by 384
Ingelsson, M., Yasri, N., & Roberts, E. P. L. (2020) · Water Research · doi:10.1016/j.watres.2020.116433 · Cited by 342
A Conceptual Overview on Sustainable Technologies for the Defluoridation of Drinking Water
Ayoob, S., Gupta, A. K., & Bhat, V. T. (2008) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380701413310 · Cited by 335
Electrocoagulation treatment of arsenic in wastewaters: A comprehensive review
Song, P., Yang, Z., Zeng, G., Yang, X., Xu, H., Wang, L., Xu, R., Xiong, W., & Ahmad, K. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.02.086 · Cited by 314
Removal of COD from laundry wastewater by electrocoagulation/electroflotation
Wang, C.-T., Chou, W.-L., & Kuo, Y.-M. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.07.122 · Cited by 286
Removal of fluoride from semiconductor wastewater by electrocoagulation–flotation
Hu, C. Y., Lo, S. L., Kuan, W. H., & Lee, Y. D. (2005) · Water Research · doi:10.1016/j.watres.2004.11.034 · Cited by 258
Self-citationGhosh, D., Medhi, C. R., & Purkait, M. K. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.08.041 · Cited by 244
Treatment of tannery wastewater by electrocoagulation
FENG, J.-W., SUN, Y.-B., ZHENG, Z., ZHANG, J.-B., LI, S., & TIAN, Y.-C. (2007) · Journal of Environmental Sciences · doi:10.1016/s1001-0742(07)60230-7 · Cited by 237
Chafi, M., Gourich, B., Essadki, A. H., Vial, C., & Fabregat, A. (2011) · Desalination · doi:10.1016/j.desal.2011.08.004 · Cited by 221
Behbahani, M., Moghaddam, M. R. A., & Arami, M. (2011) · Desalination · doi:10.1016/j.desal.2010.12.033 · Cited by 217
Malakootian, M., Mansoorian, H. J., & Moosazadeh, M. (2010) · Desalination · doi:10.1016/j.desal.2010.01.015 · Cited by 199
Fluoride distribution in electrocoagulation defluoridation process
Zhu, J., Zhao, H., & Ni, J. (2007) · Separation and Purification Technology · doi:10.1016/j.seppur.2007.01.030 · Cited by 197
Drouiche, N., Aoudj, S., Hecini, M., Ghaffour, N., Lounici, H., & Mameri, N. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.03.073 · Cited by 184
A review of fluoride in african groundwater and local remediation methods
Kut, K. M. K., Sarswat, A., Srivastava, A., Pittman, C. U., & Mohan, D. (2016) · Groundwater for Sustainable Development · doi:10.1016/j.gsd.2016.09.001 · Cited by 170
Song, S., He, Z., Qiu, J., Xu, L., & Chen, J. (2007) · Separation and Purification Technology · doi:10.1016/j.seppur.2006.12.013 · Cited by 165
Treatment of laundry waste‐water by electrocoagulation
Janpoor, F., Torabian, A., & Khatibikamal, V. (2011) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.2625 · Cited by 162
Examining Current and Future Applications of Electrocoagulation in Wastewater Treatment
Mao, Y., Zhao, Y., & Cotterill, S. (2023) · Water · doi:10.3390/w15081455 · Cited by 159
“For example, sulfate ions can impact fluoride removal due to their ability to form precipitates with Al 3+ along with fluoride ions [46].”
Background
Metadata
- Authors
- Hu, C. Y., Lo, S. L., & Kuan, W. H.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 37
- Issue
- 18
- Pages
- 4513-4523
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2081782163
- Cited by
- 275
- References
- 15
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.