X-ray computed microtomography (μCT) using synchrotron radiation (SR)
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Parfitt, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. A., Malluche, H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650020617 · Cited by 5,016
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Bone Histomorphometry : Standardization of Nomenclature, Symbols, and Units
PARFITT, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. А., Malluche, H. H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · Cited by 3,258
Evershed, R. P., Charters, S., & Quye, A. (1995) · Cambridge University Press eBooks · Cited by 2,071
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Handbook on Synchrotron Radiation
(1987) · Elsevier eBooks · doi:10.1016/c2009-0-09951-6 · Cited by 1,247
Heinrich, K. F. J. (1966) · Journal of the Franklin Institute · doi:10.1016/0016-0032(66)90032-9 · Cited by 1,166
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Cited by
A comparison of micro CT with other techniques used in the characterization of scaffolds
Ho, S. T., & Hutmacher, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.035 · Cited by 609
In vivo corrosion and corrosion protection of magnesium alloy LAE442☆
Witte, F., Fischer, J., Nellesen, J., Vogt, C., Vogt, J., Donath, T., & Beckmann, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.012 · Cited by 438
X-ray microtomography of materials
Stock, S. R. (1999) · International Materials Reviews · doi:10.1179/095066099101528261 · Cited by 366
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
Dynamical Theory of X-Ray Diffraction
Authier, A. (2003) · doi:10.1093/acprof:oso/9780198528920.001.0001 · Cited by 331
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01785.x · Cited by 277
X-ray microtomography in biology
Mizutani, R., & Suzuki, Y. (2012) · Micron · doi:10.1016/j.micron.2011.10.002 · Cited by 217
“…(also known as microcomputed tomography or micro-CT) has provided us with a practical approach to determining the three-dimensional (3D) structure of an opaque sample at micrometer to submicrometer resolution (Bonse and Busch, 1996; Salomé et al., 1999; Uesugi et al., 2001; Takeuchi et al., 2002).”
BackgroundBecker, J., Flückiger, R., Reum, M., Büchi, F. N., Marone, F., & Stampanoni, M. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3176876 · Cited by 201
Rack, A., Zabler, S., Müller, B. R., Riesemeier, H., Weidemann, G., Lange, A., Goebbels, J., Hentschel, M., & Görner, W. (2008) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.11.020 · Cited by 193
Flückiger, R., Marone, F., Stampanoni, M., Wokaun, A., & Büchi, F. N. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2010.12.016 · Cited by 173
Approaches to Single-Nanoparticle Catalysis
Sambur, J. B., & Chen, P. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103729 · Cited by 170
Fast microtomography using high energy synchrotron radiation
Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884194 · Cited by 169
The 3D-architecture of individual free silver nanoparticles captured by X-ray scattering
Barke, I., Hartmann, H., Rupp, D., Flückiger, L., Sauppe, M., Adolph, M., Schorb, S., Bostedt, C., Treusch, R., Peltz, C., et al. (2015) · Nature Communications · doi:10.1038/ncomms7187 · Cited by 100
3D Shape Characterization and Image-Based DEM Simulation of the Lunar Soil Simulant FJS-1
Matsushima, T., Katagiri, J., Uesugi, K., Tsuchiyama, A., & Nakano, T. (2009) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2009)22:1(15
Metadata
- Authors
- Bonse, U., & Busch, F.
- Venue
- Progress in Biophysics and Molecular Biology
- Publisher
- Elsevier BV
- Published
- 1996
- Volume
- 65
- Issue
- 1-2
- Pages
- 133-169
- ISSN
- 0079-6107 (ISSN-L)
- OpenAlex
- W2097517149
- Cited by
- 304
- References
- 35
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.