The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Imaging applications of synchrotron X‐ray phase‐contrast microtomography in biological morphology and biomaterials science. I. General aspects of the technique and its advantages in the analysis of millimetre‐sized arthropod structure
Abstract
Summary: Synchrotron‐generated X‐rays provide scientists with a multitude of investigative techniques well suited for the analysis of the composition and structure of all types of materials and specimens. Here, we describe the properties of synchrotron‐generated X‐rays and the advantages that they provide for qualitative morphological research of millimetre‐sized biological organisms and biomaterials. Case studies of the anatomy of insect heads, of whole microarthropods and of the three‐dimensional reconstruction of the cuticular tendons of jumping beetles, all performed at the beamline ID19 of the European Synchrotron Radiation Facility (ESRF), are presented to illustrate the techniques of phase‐contrast tomography available for anatomical and structural investigations. Various sample preparation techniques are described and compared and experimental settings that we have found to be particularly successful are given. On comparing the strengths and weaknesses of the technique with traditional histological thin sectioning, we conclude that synchrotron radiation microtomography has a great potential in biological microanatomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abràmoff, M. D., Magalhães, P. J., & Ram, S. J. (2004) · Utrecht University Repository (Utrecht University) · Cited by 11,821
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Principles of Insect Morphology
Goodrich, A. L., & Snodgrass, R. E. (1936) · Transactions of the American Microscopical Society · doi:10.2307/3223017 · Cited by 1,630
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Principles and Techniques of Electron Microscopy
Mandal, A. K., Nordquist, J. A., & Hayat, M. A. (1981) · Transactions of the American Microscopical Society · doi:10.2307/3225561 · Cited by 1,433
Electron microscopy : principles and techniques for biologists
Bozzola, J. J., & Russell, L. D. (1999) · Jones and Bartlett Publishers, Inc. eBooks · Cited by 1,352
The Insects: Structure and Function
Chapman, R. F. (1998) · Cambridge University Press eBooks · doi:10.1017/cbo9780511818202 · Cited by 1,220
Diffraction enhanced x-ray imaging
Chapman, D., Thomlinson, W., Johnston, R. E., Washburn, D., Pisano, E., Gmür, N., Zhong, Z., Menk, R., Arfelli, F., & Sayers, D. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/001 · Cited by 1,098
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Self-citationA microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Cited by
Metscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086
Metscher, B. D. (2009) · Developmental Dynamics · doi:10.1002/dvdy.21857 · Cited by 607
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
Sombke, A., Lipke, E., Michalik, P., Uhl, G., & Harzsch, S. (2015) · Journal of Comparative Neurology · doi:10.1002/cne.23741 · Cited by 144
“…of various organ systems such as the musculature, the alimentary system, and rarely the nervous system of arthropods (Tanisako et al., 2005; Betz et al., 2007; Mizutani et al., 2007, 2008a,b, 2013; Beutel et al., 2008; Friedrich and Beutel, 2008; Metscher, 2009a; Friedrich et al., 2013).”
BackgroundLe Cabec, A., Tang, N., & Tafforeau, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0123019 · Cited by 68
Metadata
- Authors
- BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2007-07
- Volume
- 227
- Issue
- 1
- Pages
- 51-71
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2046122903
- Cited by
- 277
- References
- 44
- FWCI
- 14.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging applications of synchrotron X‐ray phase‐contrast microtomography in biological morphology and biomaterials science. I. General aspects of the technique and its advantages in the analysis of millimetre‐sized arthropod structure. https://app.cochat.ai/papers/10.1111/j.1365-2818.2007.01785.x
- The paper
- BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P. (2007). Imaging applications of synchrotron X‐ray phase‐contrast microtomography in biological morphology and biomaterials science. I. General aspects of the technique and its advantages in the analysis of millimetre‐sized arthropod structure. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2007.01785.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.