Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: a randomised non-inferiority trial
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND Multislice CT (MSCT) combined with D-dimer measurement can safely exclude pulmonary embolism in patients with a low or intermediate clinical probability of this disease. We compared this combination with a strategy in which both a negative venous ultrasonography of the leg and MSCT were needed to exclude pulmonary embolism. METHODS We included 1819 consecutive outpatients with clinically suspected pulmonary embolism in a multicentre non-inferiority randomised controlled trial comparing two strategies: clinical probability assessment and either D-dimer measurement and MSCT (DD-CT strategy [n=903]) or D-dimer measurement, venous compression ultrasonography of the leg, and MSCT (DD-US-CT strategy [n=916]). Randomisation was by computer-generated blocks with stratification according to centre. Patients with a high clinical probability according to the revised Geneva score and a negative work-up for pulmonary embolism were further investigated in both groups. The primary outcome was the 3-month thromboembolic risk in patients who were left untreated on the basis of the exclusion of pulmonary embolism by diagnostic strategy. Clinicians assessing outcome were blinded to group assignment. Analysis was per protocol. This study is registered with ClinicalTrials.gov, number NCT00117169. FINDINGS The prevalence of pulmonary embolism was 20.6% in both groups (189 cases in DD-US-CT group and 186 in DD-CT group). We analysed 855 patients in the DD-US-CT group and 838 in the DD-CT group per protocol. The 3-month thromboembolic risk was 0.3% (95% CI 0.1-1.1) in the DD-US-CT group and 0.3% (0.1-1.2) in the DD-CT group (difference 0.0% [-0.9 to 0.8]). In the DD-US-CT group, ultrasonography showed a deep-venous thrombosis in 53 (9% [7-12]) of 574 patients, and thus MSCT was not undertaken. INTERPRETATION The strategy combining D-dimer and MSCT is as safe as the strategy using D-dimer followed by venous compression ultrasonography of the leg and MSCT for exclusion of pulmonary embolism. An ultrasound could be of use in patients with a contraindication to CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309
Piaggio, G., Elbourne, D. R., Pocock, S. J., Evans, S. J. W., Altman, D. G., & CONSORT Group, F. T. (2012) · JAMA · doi:10.1001/jama.2012.87802 · Cited by 2,428
Smithson, M. (2000) · SAGE Publications Ltd eBooks · doi:10.4135/9781446218525 · Cited by 1,871
Interval estimation for the difference between independent proportions: comparison of eleven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<873::aid-sim779>3.0.co;2-i · Cited by 1,851
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Reporting of Noninferiority and Equivalence Randomized Trials: An Extension of the CONSORT Statement
Piaggio, G., Elbourne, D. R., Altman, D. G., Pocock, S. J., Evans, S. J. W., & CONSORT Group, F. T. (2006) · JAMA · doi:10.1001/jama.295.10.1152 · Cited by 1,153
Prediction of Pulmonary Embolism in the Emergency Department: The Revised Geneva Score
Le Gal, G., Righini, M., Roy, P.-M., Sanchez, O., Aujesky, D., Bounameaux, H., & Perrier, A. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-3-200602070-00004 · Cited by 1,121
Self-citationDetection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography
Lensing, A. W. A., Prandoni, P., Brandjes, D., Huisman, P. M., Vigo, M., Tomasella, G., Krekt, J., ten Cate, J. W., Huisman, M. V., & Büller, H. R. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200602 · Cited by 875
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
Self-citation2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Self-citationGuidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Self-citationKonstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Self-citationPulmonary embolism and deep vein thrombosis
Goldhaber, S. Z., & Bounameaux, H. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61904-1 · Cited by 1,054
Self-citationDeep vein thrombosis and pulmonary embolism
Di Nisio, M., van Es, N., & Büller, H. R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30514-1 · Cited by 994
Age-Adjusted D-Dimer Cutoff Levels to Rule Out Pulmonary Embolism: The ADJUST-PE Study
Righini, M., Van Es, J., Den Exter, P. L., Roy, P.-M., Verschuren, F., Ghuysen, A., Rutschmann, O. T., Sanchez, O., Jaffrelot, M., Trinh-Duc, A., et al. (2014) · JAMA · doi:10.1001/jama.2014.2135 · Cited by 958
Self-citationAgnelli, G., & Becattini, C. (2010) · New England Journal of Medicine · doi:10.1056/nejmra0907731 · Cited by 444
Lim, W., Le Gal, G., Bates, S. M., Righini, M., Haramati, L. B., Lang, E., Kline, J. A., Chasteen, S., Snyder, M., Patel, P., et al. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018024828 · Cited by 418
Self-citationCARRIER, M., RIGHINI, M., WELLS, P. S., PERRIER, A., ANDERSON, D. R., RODGER, M. A., PLEASANCE, S., & LE GAL, G. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03938.x · Cited by 381
Self-citationD‐Dimer for venous thromboembolism diagnosis: 20 years later
RIGHINI, M., PERRIER, A., DE MOERLOOSE, P., & BOUNAMEAUX, H. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.02981.x · Cited by 374
Self-citationGal, G., Fine, M. J., Roy, P.-M., Sanchez, O., Verschuren, F., Cornuz, J., Meyer, G., Perrier, A., Righini, M., Aujesky, D., et al. (2008) · Thrombosis and Haemostasis · doi:10.1160/th08-05-0285 · Cited by 358
Self-citationSchouten, H. J., Geersing, G. J., Koek, H. L., Zuithoff, N. P. A., Janssen, K. J. M., Douma, R. A., van Delden, J. J. M., Moons, K. G. M., & Reitsma, J. B. (2013) · BMJ · doi:10.1136/bmj.f2492 · Cited by 342
Raja, A. S., Greenberg, J. O., Qaseem, A., Denberg, T. D., Fitterman, N., Schuur, J. D., & for the Clinical Guidelines Committee of the American College of Physicians* (2015) · Annals of Internal Medicine · doi:10.7326/m14-1772 · Cited by 340
Douma, R. A., le Gal, G., Sohne, M., Righini, M., Kamphuisen, P. W., Perrier, A., Kruip, M. J. H. A., Bounameaux, H., Buller, H. R., & Roy, P. M. (2010) · BMJ · doi:10.1136/bmj.c1475 · Cited by 340
Self-citationClinical prediction rules for pulmonary embolism: a systematic review and meta-analysis
CERIANI, E., COMBESCURE, C., LE GAL, G., NENDAZ, M., PERNEGER, T., BOUNAMEAUX, H., PERRIER, A., & RIGHINI, M. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03801.x · Cited by 337
Self-citationClinical Decision Rules for Excluding Pulmonary Embolism: A Meta-analysis
Lucassen, W., Geersing, G.-J., Erkens, P. M. G., Reitsma, J. B., Moons, K. G. M., Büller, H., & van Weert, H. C. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-7-201110040-00007 · Cited by 323
Meta‐analysis: the risk of venous thromboembolism in patients with inflammatory bowel disease
Yuhara, H., Steinmaus, C., Corley, D., Koike, J., Igarashi, M., Suzuki, T., & Mine, T. (2013) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.12294 · Cited by 220
Prognostic models in acute pulmonary embolism: a systematic review and meta-analysis
Elias, A., Mallett, S., Daoud-Elias, M., Poggi, J.-N., & Clarke, M. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010324 · Cited by 211
Propensity Score Matching: A Conceptual Review for Radiology Researchers
Baek, S., Park, S. H., Won, E., Park, Y. R., & Kim, H. J. (2015) · Korean Journal of Radiology · doi:10.3348/kjr.2015.16.2.286 · Cited by 204
“Additionally, diagnostic imaging studies can also be designed to evaluate patient outcomes associated with different diagnostic imaging methods/ strategies in order to provide higher order evidence beyond mere diagnostic accuracy (2-6).”
BackgroundDiagnosis of Pulmonary Embolism During Pregnancy: A Multicenter Prospective Management Outcome Study
Righini, M., Robert-Ebadi, H., Elias, A., Sanchez, O., Le Moigne, E., Schmidt, J., Le Gall, C., Cornuz, J., Aujesky, D., Roy, P.-M., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-1670 · Cited by 181
Self-citationEffectiveness of D-dimer as a screening test for venous thromboembolism: An update
Gurram, M., & Pulivarthi, S. (2014) · North American Journal of Medical Sciences · doi:10.4103/1947-2714.143278 · Cited by 181
“[1] In a multicenter study, the D-dimer test excluded PE in 561 patients (n = 1819) with LCP or ICP, and none of these patients had VTE in the 3-month follow-up, with a D-dimer below 500 μg FEU/l.[36]”
Diagnostic management of acute deep vein thrombosis and pulmonary embolism
Huisman, M. V., & Klok, F. A. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12124 · Cited by 176
Ahn, S., Park, S. H., & Lee, K. H. (2013) · Radiology · doi:10.1148/radiol.12120725 · Cited by 159
Pulmonary Artery Thrombosis during Acute Chest Syndrome in Sickle Cell Disease
Dessap, A. M., Deux, J.-F., Abidi, N., Lavenu-Bombled, C., Melica, G., Renaud, B., Godeau, B., Adnot, S., Brochard, L., Brun-Buisson, C., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201105-0783oc · Cited by 144
Metadata
- Authors
- Righini, M., Le Gal, G., Aujesky, D., Roy, P.-M., Sanchez, O., Verschuren, F., Rutschmann, O., Nonent, M., Cornuz, J., Thys, F., Le Manach, C. P., Revel, M.-P., Poletti, P.-A., Meyer, G., Mottier, D., Perneger, T., Bounameaux, H., & Perrier, A.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 371
- Issue
- 9621
- Pages
- 1343-1352
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2162455380
- Cited by
- 420
- References
- 22
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.