Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationPathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Self-citationSafety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Self-citationOutcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationFinn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277
Analysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., Menichelli, M., Sabaté, M., Suttorp, M. J., Baumgart, D., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067484 · Cited by 1,006
Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066633 · Cited by 704
Self-citationWindecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Self-citation
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citation(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Self-citationFarooq, V., van Klaveren, D., Steyerberg, E. W., Meliga, E., Vergouwe, Y., Chieffo, A., Kappetein, A. P., Colombo, A., Holmes, D. R., Mack, M., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60108-7 · Cited by 840
Self-citationDrug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 728
Self-citationMehran, R., Baber, U., Steg, P. G., Ariti, C., Weisz, G., Witzenbichler, B., Henry, T. D., Kini, A. S., Stuckey, T., Cohen, D. J., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61720-1 · Cited by 616
Werner, G. S., Martin-Yuste, V., Hildick-Smith, D., Boudou, N., Sianos, G., Gelev, V., Rumoroso, J. R., Erglis, A., Christiansen, E. H., Escaned, J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy220 · Cited by 581
Self-citationBiodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
Self-citationThe importance of the endothelium in atherothrombosis and coronary stenting
Otsuka, F., Finn, A. V., Yazdani, S. K., Nakano, M., Kolodgie, F. D., & Virmani, R. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.64 · Cited by 402
Stefanini, G. G., Byrne, R. A., Serruys, P. W., de Waha, A., Meier, B., Massberg, S., Juni, P., Schomig, A., Windecker, S., & Kastrati, A. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs086 · Cited by 384
Self-citationHead, S. J., Davierwala, P. M., Serruys, P. W., Redwood, S. R., Colombo, A., Mack, M. J., Morice, M.-C., Holmes, D. R., Feldman, T. E., Stahle, E., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu213 · Cited by 361
Self-citationGilard, M., Barragan, P., Noryani, A. A. L., Noor, H. A., Majwal, T., Hovasse, T., Castellant, P., Schneeberger, M., Maillard, L., Bressolette, E., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.11.008 · Cited by 360
Self-citationSerruys, P. W., Farooq, V., Kalesan, B., de Vries, T., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.04.011 · Cited by 331
Self-citation2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy14m09_01 · Cited by 328
Self-citationPalmerini, T., Biondi-Zoccai, G., Della Riva, D., Mariani, A., Sabaté, M., Smits, P. C., Kaiser, C., D'Ascenzo, F., Frati, G., Mancone, M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.09.061 · Cited by 313
Macroscale delivery systems for molecular and cellular payloads
Kearney, C. J., & Mooney, D. J. (2013) · Nature Materials · doi:10.1038/nmat3758 · Cited by 301
Räber, L., Kelbæk, H., Ostojic, M., Baumbach, A., Heg, D., Tüller, D., von Birgelen, C., Roffi, M., Moschovitis, A., Khattab, A. A., et al. (2012) · JAMA · doi:10.1001/jama.2012.10065 · Cited by 298
Self-citationSmits, P. C., Hofma, S., Togni, M., Vázquez, N., Valdés, M., Voudris, V., Slagboom, T., Goy, J.-J., Vuillomenet, A., Serra, A., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61852-2 · Cited by 293
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Self-citationPilgrim, T., Heg, D., Roffi, M., Tüller, D., Muller, O., Vuilliomenet, A., Cook, S., Weilenmann, D., Kaiser, C., Jamshidi, P., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61038-2 · Cited by 267
Self-citationCurrent Status of Bioresorbable Scaffolds in the Treatment of Coronary Artery Disease
Wiebe, J., Nef, H. M., & Hamm, C. W. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.041 · Cited by 255
Pharmapolymers in the 21st century: Synthetic polymers in drug delivery applications
Englert, C., Brendel, J. C., Majdanski, T. C., Yildirim, T., Schubert, S., Gottschaldt, M., Windhab, N., & Schubert, U. S. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.07.005 · Cited by 247
Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent
Natsuaki, M., Kozuma, K., Morimoto, T., Kadota, K., Muramatsu, T., Nakagawa, Y., Akasaka, T., Igarashi, K., Tanabe, K., Morino, Y., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.045 · Cited by 205
“Regarding late adverse events, use of BioMatrix was clearly associated with fewer cardiac events related to very late ST in the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial, suggesting that the potential benefit of BES would only emerge at very longterm follow-up (7).”
BackgroundPuricel, S., Arroyo, D., Corpataux, N., Baeriswyl, G., Lehmann, S., Kallinikou, Z., Muller, O., Allard, L., Stauffer, J.-C., Togni, M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.12.017 · Cited by 203
Primary Endpoint Results of the EVOLVE Trial
Meredith, I. T., Verheye, S., Dubois, C. L., Dens, J., Fajadet, J., Carrié, D., Walsh, S., Oldroyd, K. G., Varenne, O., El-Jack, S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.016 · Cited by 203
Christiansen, E. H., Jensen, L. O., Thayssen, P., Tilsted, H.-H., Krusell, L. R., Hansen, K. N., Kaltoft, A., Maeng, M., Kristensen, S. D., Bøtker, H. E., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61962-x · Cited by 201
Long-Term Results After Simple Versus Complex Stenting of Coronary Artery Bifurcation Lesions
Maeng, M., Holm, N. R., Erglis, A., Kumsars, I., Niemelä, M., Kervinen, K., Jensen, J. S., Galløe, A., Steigen, T. K., Wiseth, R., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.015 · Cited by 177
“In percutaneous coronary intervention (PCI), long-term clinical results are the ultimate assessment of different treatment modalities or devices (6,7).”
BackgroundKang, S.-H., Park, K. W., Kang, D.-Y., Lim, W.-H., Park, K. T., Han, J.-K., Kang, H.-J., Koo, B.-K., Oh, B.-H., Park, Y.-B., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht570 · Cited by 168
Bioresorbable Stents: Is This Where We Are Headed?
Wayangankar, S. A., & Ellis, S. G. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.08.011 · Cited by 18
Metadata
- Authors
- Stefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., Morice, M.-C., Di Mario, C., Corti, R., Antoni, D., Sohn, H. Y., Eerdmans, P., van Es, G.-A., Meier, B., Windecker, S., & Jüni, P.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2011-12
- Volume
- 378
- Issue
- 9807
- Pages
- 1940-1948
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2145622970
- Cited by
- 354
- References
- 34
- FWCI
- 61.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.