Antimicrobial catheters for reduction of symptomatic urinary tract infection in adults requiring short-term catheterisation in hospital: a multicentre randomised controlled trial
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital. We aimed to establish whether short-term routine use of antimicrobial catheters reduced risk of CAUTI compared with standard polytetrafluoroethylene (PTFE) catheterisation. METHODS In our parallel, three group, multicentre, randomised controlled superiority trial, we enrolled adults (aged ≥16 years) requiring short-term (≤14 days) catheterisation at 24 hospitals in the UK. Participants were randomly allocated 1:1:1 with a remote computer allocation to receive a silver alloy-coated catheter, a nitrofural-impregnated catheter, or a PTFE-coated catheter (control group). Patients undergoing unplanned catheterisation were also included and consent for participation was obtained retrospectively. Participants and trial staff were unmasked to treatment assignment. Data were collected by trial staff and by patient-reported questionnaires for 6 weeks after randomisation. The primary outcome was incidence of symptomatic urinary tract infection for which an antibiotic was prescribed by 6 weeks. We postulated that a 3·3% absolute reduction in CAUTI would represent sufficient benefit to recommend routine use of antimicrobial catheters. This study is registered, number ISRCTN75198618. FINDINGS 708 (10%) of 7102 randomly allocated participants were not catheterised, did not confirm consent, or withdrew, and were not included in the primary analyses. Compared with 271 (12·6%) of 2144 participants in the control group, 263 (12·5%) of 2097 participants allocated a silver alloy catheter had the primary outcome (difference -0·1% [95% CI -2·4 to 2·2]), as did 228 (10·6%) of 2153 participants allocated a nitrofural catheter (-2·1% [-4·2 to 0·1]). Rates of catheter-related discomfort were higher in the nitrofural group than they were in the other groups. INTERPRETATION Silver alloy-coated catheters were not effective for reduction of incidence of symptomatic CAUTI. The reduction we noted in CAUTI associated with nitrofural-impregnated catheters was less than that regarded as clinically important. Routine use of antimicrobial-impregnated catheters is not supported by this trial. FUNDING UK National Institute for Health Research Health Technology Assessment Programme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
Hooton, T. M., Bradley, S. F., Cardenas, D. D., Colgan, R., Geerlings, S. E., Rice, J. C., Saint, S., Schaeffer, A. J., Tambayh, P. A., Tenke, P., et al. (2010) · Clinical Infectious Diseases · doi:10.1086/650482 · Cited by 2,099
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Guideline for Prevention of Catheter-Associated Urinary Tract Infections 2009
Gould, C. V., Umscheid, C. A., Agarwal, R. K., Kuntz, G., Pegues, D. A., & Healthcare Infection Control Practices Advisory Committee (HICPAC) (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/651091 · Cited by 1,405
Umscheid, C. A., Mitchell, M. D., Doshi, J. A., Agarwal, R., Williams, K., & Brennan, P. J. (2011) · Infection Control & Hospital Epidemiology · doi:10.1086/657912 · Cited by 1,210
Discrepancies between Meta-Analyses and Subsequent Large Randomized, Controlled Trials
LeLorier, J., Grégoire, G., Benhaddad, A., Lapierre, J., & Derderian, F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199708213370806 · Cited by 1,171
Pratt, R. J., Pellowe, C. M., Wilson, J. A., Loveday, H. P., Harper, P. J., Jones, S. R. L. J., McDougall, C., & Wilcox, M. H. (2007) · Journal of Hospital Infection · doi:10.1016/s0195-6701(07)60002-4 · Cited by 725
UK population norms for EQ-5DPreprint
Kind, P., Hardman, G., & Macran, S. (1999) · RePEc: Research Papers in Economics · Cited by 443
Prevention of Catheter-Induced Urinary-Tract Infections by Sterile Closed Drainage
Kunin, C. M., & McCormack, R. C. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742101 · Cited by 438
Johnson, J. R., Kuskowski, M. A., & Wilt, T. J. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-2-200601170-00009 · Cited by 323
Cited by
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Ford, I., & Norrie, J. (2016) · New England Journal of Medicine · doi:10.1056/nejmra1510059 · Cited by 1,405
Self-citationA review of the biomaterials technologies for infection-resistant surfaces
Campoccia, D., Montanaro, L., & Arciola, C. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.089 · Cited by 1,358
Lebeaux, D., Ghigo, J.-M., & Beloin, C. (2014) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00013-14 · Cited by 1,318
Healthcare-associated infections, medical devices and biofilms: risk, tolerance and control
Percival, S. L., Suleman, L., Vuotto, C., & Donelli, G. (2015) · Journal of Medical Microbiology · doi:10.1099/jmm.0.000032 · Cited by 736
ESCMID∗ guideline for the diagnosis and treatment of biofilm infections 2014
Høiby, N., Bjarnsholt, T., Moser, C., Bassi, G. L., Coenye, T., Donelli, G., Hall-Stoodley, L., Holá, V., Imbert, C., Kirketerp-Møller, K., et al. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2014.10.024 · Cited by 726
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
From in vitro to in vivo Models of Bacterial Biofilm-Related Infections
Lebeaux, D., Chauhan, A., Rendueles, O., & Beloin, C. (2013) · Pathogens · doi:10.3390/pathogens2020288 · Cited by 545
Lo, E., Nicolle, L. E., Coffin, S. E., Gould, C., Maragakis, L. L., Meddings, J., Pegues, D. A., Pettis, A. M., Saint, S., & Yokoe, D. S. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/675718 · Cited by 516
Applying insights from biofilm biology to drug development — can a new approach be developed?
Bjarnsholt, T., Ciofu, O., Molin, S., Givskov, M., & Høiby, N. (2013) · Nature Reviews Drug Discovery · doi:10.1038/nrd4000 · Cited by 516
A review of the recent advances in antimicrobial coatings for urinary catheters
Singha, P., Locklin, J., & Handa, H. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.070 · Cited by 448
Meddings, J., Rogers, M. A. M., Krein, S. L., Fakih, M. G., Olmsted, R. N., & Saint, S. (2014) · BMJ Quality & Safety · doi:10.1136/bmjqs-2012-001774 · Cited by 431
The emerging threat of multidrug-resistant Gram-negative bacteria in urology
Zowawi, H. M., Harris, P. N. A., Roberts, M. J., Tambyah, P. A., Schembri, M. A., Pezzani, M. D., Williamson, D. A., & Paterson, D. L. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.199 · Cited by 361
(2013) · doi:10.2217/ahe.13.38 · Cited by 321
Reporting of Multi-Arm Parallel-Group Randomized Trials: Extension of the CONSORT 2010 Statement
Juszczak, E., Altman, D. G., Hopewell, S., & Schulz, K. (2019) · JAMA · doi:10.1001/jama.2019.3087 · Cited by 324
Metal-Based Nanoparticles for the Treatment of Infectious Diseases
Aderibigbe, B. (2017) · Molecules · doi:10.3390/molecules22081370 · Cited by 269
Yu, K., Lo, J. C. Y., Yan, M., Yang, X., Brooks, D. E., Hancock, R. E. W., Lange, D., & Kizhakkedathu, J. N. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.11.047 · Cited by 256
Bacterial biofilm formation on indwelling urethral catheters
Pelling, H., Nzakizwanayo, J., Milo, S., Denham, E. L., MacFarlane, W. M., Bock, L. J., Sutton, J. M., & Jones, B. V. (2019) · Letters in Applied Microbiology · doi:10.1111/lam.13144 · Cited by 171
“…manufacturers that such devices are effective in preventing catheter encrustation, current evidence suggest these general strategies perform poorly in the control of P. mirabilis crystalline biofilm formation (Morris et al. 1997; Stickler and Morgan 2008; Desai et al. 2010; Pickard et al. 2012).”
BackgroundResultInfluentialFisher, L. E., Hook, A. L., Ashraf, W., Yousef, A., Barrett, D. A., Scurr, D. J., Chen, X., Smith, E. F., Fay, M., Parmenter, C. D. J., et al. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.01.037 · Cited by 169
Metadata
- Authors
- Pickard, R., Lam, T., MacLennan, G., Starr, K., Kilonzo, M., McPherson, G., Gillies, K., McDonald, A., Walton, K., Buckley, B., Glazener, C., Boachie, C., Burr, J., Norrie, J., Vale, L., Grant, A., & N'Dow, J.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 380
- Issue
- 9857
- Pages
- 1927-1935
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2150073915
- Cited by
- 252
- References
- 22
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.