Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial
The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Abstract
Background The effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals. Methods The HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTria…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CGM can reveal asymptomatic hypoglycemia and help identify patterns and precipitants of hypoglycemic events and provide alarms that can warn individuals of falling glucose so that they can intervene (150,151).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [150]
In the citing paper
“Several clinical trials have not shown a reduction of IAH by using CGM despite a reduced incidence of level 3 hypoglycemia (101,112,124,126-128).”
In the citing paper
“Hypoglycemia with glucose levels below 3.0 mmol/L (54 mg/dL) occurs much more often than previously appreciated (46,101).”
In the citing paper
“Reductions in HbA1c have been reported with CGM use in people on multiple daily injection (MDI) therapy,19 and continuous subcutaneous insulin infusion therapy,20 with reduced time spent in hypoglycemia,20 and improved hypoglycemia awareness.21”
From Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen (2020) · cites this paper as [21]
In the citing paper
“The leading CGMs on market today are Dexcom (CA, USA), Medtronic (MN, USA) and Abbott (IL, USA) devices [2-5,19,31].”
From Wearables and the Medical Revolution (2018) · cites this paper as [19]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490
Hypoglycaemia in diabetes mellitus: epidemiology and clinical implications
Frier, B. M. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.170 · Cited by 481
Cited by
Items 301–400 of 528
Pieri, B. A., Deshmukh, H., Wilmot, E. G., Choudhary, P., Shah, N. Z., Gregory, R., Barnes, D., Saunders, S., Patmore, J., Walton, C., et al. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14841 · Cited by 9
Practical Application of Continuous Glucose Monitoring in Clinical Practice: Case Studies
Unger, J., & Franco, D. R. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0080 · Cited by 7
Maiorino, M. I., Buzzetti, R., Irace, C., Laviola, L., Napoli, N., Pitocco, D., Esposito, K., & on behalf of LIVE CGM working group (2023) · Endocrine · doi:10.1007/s12020-023-03473-w · Cited by 7
Lee, Y., Kim, M., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0032 · Cited by 9
Kublin, O., & Stȩpień, M. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819900257 · Cited by 7
Jensch, H., Setford, S. J., Thomé, N., Srikanthamoorthy, G., Weingärtner, L., Grady, M., Holt, E., & Pfützner, A. (2025) · Sensors · doi:10.3390/s25071985 · Cited by 11
The impact of technology on impaired awareness of hypoglycaemia in type 1 diabetes
Berry, S. A., Goodman, I., Heller, S. R., & Iqbal, A. (2025) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188251346260 · Cited by 8
“41 The incidence risk ratio of SH with rtCGM compared to SMBG was 0.36 ( p = 0.0247).”
InfluentialSvensson, C. H., Fabricius, T. W., Verhulst, C. E. M., Kristensen, P. L., Tack, C. J., Heller, S. R., Amiel, S. A., McCrimmon, R. J., Evans, M. L., Holst, J. J., et al. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15649 · Cited by 8
Chan, A. J., & Halperin, I. J. (2020) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2020.08.103 · Cited by 6
Diabetes mellitus Typ 1 – Update
Kordonouri, O., & Kerner, W. (2021) · Der Internist · doi:10.1007/s00108-021-01009-w · Cited by 6
Wysham, C., & Kruger, D. F. (2021) · Journal of the Endocrine Society · doi:10.1210/jendso/bvab064 · Cited by 7
Orem’in Öz Bakım Eksikliği Kuramına Göre Diyabet Teknolojileri
Polat, G., & Avdal, E. Ü. (2021) · Etkili Hemşirelik Dergisi · doi:10.46483/deuhfed.865886 · Cited by 8
“Yapılan çalışmalar diyabet teknolojilerinin sağlık sonuçlarını iyileştirdiğini göstermiştir (6,7).”
Visser, M. M., Charleer, S., Fieuws, S., Block, C. E. M. D., Hilbrands, R., Huffel, L. V., Maes, T., Vanhaverbeke, G., Dirinck, E. L., Myngheer, N., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221128315 · Cited by 7
Serné, E. H., van den Berg, I. K., Racca, C., van Raalte, D. H., Kramer, M. H. H., de Wit, M., & Snoek, F. J. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0232 · Cited by 8
“16 The increased use of hybrid closed loop systems (almost 30% of the participants), which was not available during the other studies, might partly explain this better performance.”
Hyperglycaemia aversion in type 1 diabetes: A grounded theory study
McKechnie, V., Oliver, N. S., Amiel, S. A., & Fox, J. R. E. (2023) · British Journal of Health Psychology · doi:10.1111/bjhp.12697 · Cited by 9
Ehrmann, D., Priesterroth, L., Olesen, B., Haak, T., Kulzer, B., & Hermanns, N. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0333 · Cited by 7
“7,8 Real-world data corroborate these findings and showed the beneficial effects of CGM initiation within the 1st year of type 1 diabetes diagnosis 9 as well as reduced severe hypoglycemic events and ketoacidosis after CGM initiation.”
Self-citationPerea, V., Giménez, M., Amor, A. J., Bellart, J., Conget, I., & Vinagre, I. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.06.015 · Cited by 11
USA Vs Europe: Who Is Leading the Diabetes Tech Race?
Acosta, G. J., Brown, S. J., Zand, A., Kansara, A., & Sadhu, A. (2019) · Current Diabetes Reports · doi:10.1007/s11892-019-1237-z · Cited by 7
Awareness of hypoglycemia and spectral analysis of heart rate variability in type 1 diabetes
Paes, T., Rolim, L. C., Filho, C. S., de Sá, J. R., & Dib, S. A. (2020) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2020.107617 · Cited by 7
Mönnig, E., Spaepen, E., Osumili, B., Mitchell, B. D., Snoek, F. J., Peyrot, M. F., Kern, W., & Holstein, A. (2020) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1310-7963 · Cited by 6
Characteristics of Nocturnal Hypoglycaemic Events and Their Impact on Glycaemia
Eichenlaub, M., Öter, Ş., Waldenmaier, D., Kulzer, B., Heinemann, L., Ziegler, R., Schnell, O., Glatzer, T., & Freckmann, G. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267765 · Cited by 6
Self-citationYoo, J. H., Moon, S. J., Park, C.-Y., & Kim, J. H. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241262106 · Cited by 11
Glycemia Risk Index is Associated With Risk of Albuminuria Among Individuals With Type 1 Diabetes
Kim, J. Y., Yoo, J. H., Kim, N. H., & Kim, J. H. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241310850 · Cited by 5
A low-power approach to optical glucose sensing via polarisation switching
Hassanpour, E., Nasehi, M., Meymandinezhad, A., & Witthauer, L. (2025) · Scientific Reports · doi:10.1038/s41598-025-99367-0 · Cited by 5
McKechnie, V., Avari, P., Eng, P. C., Unsworth, R., Reddy, M., Amiel, S. A., Salem, V., & Misra, S. (2025) · PLoS ONE · doi:10.1371/journal.pone.0320702 · Cited by 5
“Real-time continuous glucose monitoring (rtCGM) is associated with lower HbA1c levels [8–11], and benefits are linked to wear-time [12]; in the JDRF-CGM randomized controlled trial (RCT), [13], participants aged >25-years experienced a reduction in HbA1c associated with sensor wear-time, however no…”
Oliver, N. S., Chow, E., Luk, A. O. Y., & Murphy, H. R. (2023) · Diabetic Medicine · doi:10.1111/dme.15038 · Cited by 6
Pfützner, A., Tencer, B., Stamm, B., Mehta, M., Sharma, P., Gilyazev, R., Jensch, H., Thomé, N., & Huth, M. (2023) · Sensors · doi:10.3390/s23094541 · Cited by 5
Hypoglycemia in Type 1 Diabetes Mellitus
Şakar, K., & Çınar, N. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1004108 · Cited by 9
Thomas, A., Haak, T., Tombek, A., Kulzer, B., Ehrmann, D., Kordonouri, O., Kröger, J., Schubert-Olesen, O., Kolassa, R., Siegmund, T., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267768 · Cited by 5
Self-citationJensen, M. H., Dethlefsen, C., Hejlesen, O. K., & Vestergaard, P. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819848721 · Cited by 6
Ling, Q., Lü, J., Li, X., Qiao, C., Zhu, D., & Bi, Y. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00787-0 · Cited by 6
Applying Real-World Data to Inform Continuous Glucose Monitoring Use in Clinical Practice
Zheng, Y., Siminerio, L. M., Krall, J. S., Anton, B. B., Hodges, J. C., BEDNARZ, L. L., Li, D., & Ng, J. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821997403 · Cited by 5
Use of Continuous Glucose Monitoring to Facilitate Perioperative Glycemic Management: A Case Report
DiGiusto, M., Wolf, R. M., Arcara, K. M., & Vanderhoek, S. M. (2021) · A&A Practice · doi:10.1213/xaa.0000000000001438 · Cited by 5
Continuous and Intermittent Glucose Monitoring in 2022
Dovč, K., Bode, B. W., & Battelino, T. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.2502 · Cited by 6
Advancements in Diabetes Technology Are Outpacing the Evidence
Rickson, M., Wright, E. E., Bindal, A., & Ghonim, L. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0145 · Cited by 8
Jensen, M. H., Vestergaard, P., Hirsch, I. B., & Hejlesen, O. K. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820957662 · Cited by 5
Wylie, T. A. F., Shah, C., Burgess, L. C., Robertson, E., Dupont, D., Swindell, R., Hovorka, R., Murphy, H. R., & Heller, S. R. (2021) · Diabetic Medicine · doi:10.1111/dme.14647 · Cited by 5
Lin, Y. K., Chan, O. T. M., & Fisher, S. J. (2019) · Endocrine Practice · doi:10.4158/1934-2403-25.10.1080 · Cited by 5
Kanazawa, K., Suzuki, S., Koga, S., & Kuwabara, K. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2022.108239 · Cited by 4
Uduku, C. N., Pendolino, V., Jugnee, N., Oliver, N. S., Fothergill, R. T., & Reddy, M. (2023) · Diabetic Medicine · doi:10.1111/dme.15100 · Cited by 5
Cost-Utility of Real-Time Potassium Monitoring in United States Patients Receiving Hemodialysis
Bamforth, R. J., Ferguson, T. W., Tangri, N., Rigatto, C., Collister, D., & Komenda, P. V. J. (2024) · Kidney International Reports · doi:10.1016/j.ekir.2024.08.007 · Cited by 4
Neue Therapieoptionen mit kontinuierlich gemessenen Glukosedaten – Empfehlungen für die Praxis
Seufert, J., Deiss, D., Gölz, S., Haak, T., Klausmann, G., Kroeger, J., Lobmann, R., Pfeiffer, A. F. H., Schnell, O., Seibold, A., et al. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/a-0978-4537 · Cited by 4
“[23] Heinemann L, Freckmann G, Ehrmann D et al.”
BackgroundBlissett, D. B., Attvall, S., & Hellmund, R. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01099-7 · Cited by 4
“The cost inputs, reported in Table 1, were sourced from Swedish price lists, manufacturer data and resource use reported in the control arm of the HypoDE study [12], an RCT that compared CGM to routine SMBG in a population predominantly of people with IAH.”
MethodResultInfluentialTakagi, S., Miura, J., Shimura, K., Hoshina, S., Tsuchida, Y., Takita, M., Mochizuki, S., Shen, Z., Asanuma, T., Takaike, H., et al. (2021) · Diabetology International · doi:10.1007/s13340-021-00538-x · Cited by 6
Sathyanarayanan, A., Crabtree, T. S. J., Choudhary, P., Elliott, D., Evans, M. L., Lumb, A. N., & Wilmot, E. G. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109777 · Cited by 4
“[15,16] NICE recommends rtCGM for those with problematic hypoglycaemia and hyperglycaemia.”
BackgroundDiabetes Therapy Podcast: Real-World Data for Glucose Sensing Technologies in Type 1 Diabetes
Oliver, N. S. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01331-y · Cited by 5
“And really importantly, for people at highest risk of severe hypoglycemia requiring the assistance of a third party for active treatment, RT-CGM can reduce the incidence of those severe episodes [6], and that is really important because they can be incredibly disabling and they are associated with morbidity and mortal…”
BackgroundCourtney, A., Smith, D., & Forde, H. E. (2023) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-023-03322-9 · Cited by 4
“Continuous glucose monitoring overwhelmingly has been shown to contribute to improvements in diabetes-specific quality of life measures and overall treatment satisfaction [3, 5, 7].”
BackgroundSakane, S., Kato, K., Hata, S., Nishimura, E., Araki, R., Kouyama, K., Hatao, M., Matoba, Y., Matsushita, Y., Domichi, M., et al. (2024) · Diabetology International · doi:10.1007/s13340-024-00733-6 · Cited by 4
“The use of rtCGM reduced the number of hypoglycemic events in individuals with T1D treated for MDI, IAH, or SH [32].”
Garden, G. L., Frier, B. M., Hine, J. L., Hutchison, E. J., Mitchell, S. J., Shaw, K. M., Heller, S. R., Koehler, G., Hofmann, V., Gaffney, T. P., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14471 · Cited by 5
Thomas, A., Haak, T., Tombek, A., Kulzer, B., Ehrmann, D., Kordonouri, O., Kroeger, J., Schubert-Olesen, O., Kolassa, R., Siegmund, T., et al. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1849-2137 · Cited by 4
“Unterstützend sind hierbei einstellbare Alarme, insbesondere prädiktive Warnungen, die helfen die Anzahl und Schwere von Hypoglykämien und Rebound-Hyperglykämien zu reduzieren.”
BackgroundInfluentialSelf-citationGuideline Development for Medical Device Technology: Issues for Consideration
Battelino, T., Brosius, F. C., Ceriello, A., Cosentino, F., Green, J., Kellerer, M., Koob, S., Kosiborod, M., Lalic, N. M., Marx, N., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221093355 · Cited by 5
Rickards, G. M., Harrod, J. C., Valle, K. L. D., Caballero, A. E., Palermo, N. E., & McDonnell, M. E. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241288917 · Cited by 6
Hermanns, N., Heinemann, L., Kulzer, B., Schäfer, A., Jacobsen, M., & Ehrmann, D. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112228 · Cited by 5
Self-citationBehnke, A., Lucas, K. S., Parkin, C. G., Reddy, V., Orlowski, M., & Edwards, A. (2025) · Diabetes Spectrum · doi:10.2337/ds24-0085 · Cited by 3
van Laar, A., Gallardo‐Nuell, L., Pazmiño, S., Visser, M. M., Mertens, A. C., Vangoitsenhoven, R., Gillard, P., Al‐Ozairi, E., le Roux, C. W., Rosen, J., et al. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103589 · Cited by 4
Kim, J. Y., Kim, J. H., & Kim, J. H. (2026) · Diabetologia · doi:10.1007/s00125-026-06709-2 · Cited by 4
“Several randomised controlled trials (RCTs) have confirmed the glycaemic benefits of CGM [5–7].”
Zhu, T., Howson, J. M. M., & Nevado‐Holgado, A. J. (2026) · EBioMedicine · doi:10.1016/j.ebiom.2026.106343 · Cited by 4
Heald, A. H., Stedman, M., Warner-Levy, J. J., Belston, L., Paisley, A. N., Jotić, A., Lalic, N. M., Gibson, M., Habte‐Asres, H. H., Whyte, M., et al. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01647-x · Cited by 3
Overview of Currently Available Insulin Delivery Systems
Fried, H. (2024) · Contemporary Endocrinology · doi:10.1007/978-3-031-75352-7_2 · Cited by 4
Disease Detection Using Ensemble Model in Machine Learning
Mohapatra, R., Giri, P. K., Sayyad, I., Sahu, A., Brahma, B., & Kamila, N. K. (2025) · SN Computer Science · doi:10.1007/s42979-025-03753-4 · Cited by 3
“In treating type 1 diabetes [22, 23] and type 2 diabetes [24], these systems have considerably enhanced glycemic control.”
Is hypoglycemia expensive in China?
Lan, K., Wang, J., Nicholas, S., Tang, Q., Chang, A., & Xu, J. (2021) · Medicine · doi:10.1097/md.0000000000024067 · Cited by 3
“Surprisingly, hypoglycemia is often neglected as a risk among diabetes patients, with potentially significant health consequences for individuals and the health service system.([12]) McCoy et al reported that the mortality in diabetes patients who self-reported severe hypoglycemia 5 years earlier was 3.”
BackgroundSehgal, S., Elbalshy, M. M., Williman, J. A., Galland, B. C., Crocket, H. R., Hall, R. M., Paul, R. G., Leikis, R., de Bock, M. I., & Wheeler, B. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231196562 · Cited by 3
Gaulke, A., Giordano, J., & Grossman, D. S. (2023) · Medical Care · doi:10.1097/mlr.0000000000001917 · Cited by 3
Scientific Production Dynamics in mHealth for Diabetes: Scientometric Analysis
Castillo-Valdez, P. F., Rodríguez-Salvador, M., & Ho, Y. (2024) · JMIR Diabetes · doi:10.2196/52196 · Cited by 4
Kanazawa, K., Hijikata, M., & Kuwabara, K. (2024) · Endocrine Practice · doi:10.1016/j.eprac.2024.10.009 · Cited by 3
Surgical options for glycaemic control in Type 1 diabetes
Yeung, K. T. D., Reddy, M., & Purkayastha, S. (2019) · Diabetic Medicine · doi:10.1111/dme.13885 · Cited by 3
“RT-CGM also increases time spent in target glucose range and reduces severe hypoglycaemia (requiring third party assistance to treat) in Type 1 diabetes participants with impaired awareness of hypoglycaemia, compared with SMBG(10, 11) and reduces diabetes related distress(12).”
BackgroundRole of Whole Organ Pancreas Transplantation in the Day of Bioartificial and Artificial Pancreas
Manay, P., Turgeon, N. A., & Axelrod, D. A. (2020) · Current Transplantation Reports · doi:10.1007/s40472-020-00300-3 · Cited by 4
New technical approach to the diabetes therapy
Dovč, K., & Battelino, T. (2020) · Minerva Pediatrics · doi:10.23736/s0026-4946.20.05865-x · Cited by 3
Lucidi, P., Porcellati, F., Bolli, G. B., & Fanelli, C. G. (2018) · Annals of Translational Medicine · doi:10.21037/atm.2018.11.23 · Cited by 3
Use of Retrospective Continuous Glucose Monitoring Data Is Underrated and Underused
Nguyen, Q., Iyyavoo, A. A., & Parkin, C. G. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211070837 · Cited by 4
Steenackers, N., Sparsø, T., Charleer, S., Block, C. E. M. D., Cock, D. D., Delfin, C., Mathieu, C., Nobels, F. R. E., Pazmiño, S., Rosen, J., et al. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15886 · Cited by 2
Glucose management indicator: Do we need device-specific equations?
Jávorfi, T., Kocsis, G., Svébis, M. M., Ferencz, V., Domján, B. A., Kézdi, Á., Hankó, H., Putz, Z., & Tabák, Á. G. (2025) · Diabetes & Metabolism · doi:10.1016/j.diabet.2025.101661 · Cited by 4
Wang, R., Krishnamoorthi, B., Connell, A., Chiang, C. Y., Renouf, D., Barmanray, R., Kyi, M., & Fourlanos, S. (2025) · Internal Medicine Journal · doi:10.1111/imj.70095 · Cited by 2
Glukosemessung in der Diabetestherapie
Pleus, S., Buck, S., Heinemann, L., & Freckmann, G. (2025) · Die Diabetologie · doi:10.1007/s11428-025-01338-6 · Cited by 2
Self-citationSchiavon, M., Vella, A. V., & Man, C. D. (2025) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00407.2024 · Cited by 3
Khowaja, A. A., Adil, L., Dwyer, T., Barrett, T. S., & Alkhaddo, J. B. (2025) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2025.100274 · Cited by 2
Gan, K., Zhao, Z., Zhang, B., Li, T., Wang, S. H., Chang‐Liao, K., & Ruan, D. (2025) · Vacuum · doi:10.1016/j.vacuum.2025.114855 · Cited by 2
Continuous glucose monitoring in high-risk individuals
Chen, Z., Zhang, Y., Sun, L., & Guo, W. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120733 · Cited by 4
New paths to attenuate the burden of hypoglycaemia in type 1 diabetes
Monnier, L., & Ds, O. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70512 · Cited by 2
Okyay, T. M., Yilmaz, I., & Koldaş, M. (2026) · Scientific Reports · doi:10.1038/s41598-025-20234-z · Cited by 2
Letissier, N. B., Rault, C. C. S., Faucher, C., Rabois, E., Durocher, L., Bouleti, C., Ragot, S., Hadjadj, S., Mosbah, H., Piguel, X., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261423954 · Cited by 2
Kontinuierliche Glukosemessung: Auf dem Weg zum Standard in der Diabetestherapie
Gehr, B., & Biester, T. (2018) · Der Diabetologe · doi:10.1007/s11428-018-0383-2 · Cited by 2
The implementation of modern technology into standard of care of type 1 diabetes
Petruželková, L., Plachý, L., Kajprová, M., Neuman, V., Obermannová, B., Průhová, Š., Lebl, J., Koloušková, S., & Šumník, Z. (2022) · Česko-slovenská pediatrie · doi:10.55095/cspediatrie2022/010 · Cited by 2
Oraibi, O., Alameer, A., Dalak, M., Alsharif, S., Hakami, S. A., Sumayli, M. A. A., Shami, A., Mohrag, M., Madkhali, M. A., Madkhali, M. A., et al. (2024) · Current Diabetes Reviews · doi:10.2174/0115733998288242240104054438 · Cited by 3
Ortiz-Zúñiga, Á., Amigó, J., Sánchez, M. D. F. G., Abad, M., Simó, R., Hernández, C., & Simó‐Servat, O. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111786 · Cited by 2
Hannah, K. L., Nemlekar, P. M., Bushman, J. S., & Norman, G. J. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15982 · Cited by 2
Maiorino, M. I., Martino, N. D., Angelino, S., Maio, A., Caruso, P., Petrizzo, M., Scappaticcio, L., Longo, M., Forestiere, D., Porcellini, C., et al. (2025) · Endocrine · doi:10.1007/s12020-025-04405-6 · Cited by 4
Diabetes-Technologie: Stand der Dinge
Heinemann, L. (2018) · Diabetologie und Stoffwechsel · doi:10.1055/s-0043-124750 · Cited by 2
Self-citationTreatment of type 1 diabetes complicated by problematic hypoglycemia
Jacob, P., CHANDRAN, S. R., & Choudhary, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814833-4.00032-0 · Cited by 3
Recomendaciones para la práctica clínica: hipoglucemia en personas con diabetes mellitus
Martín, C. G., Loredo, S. D., Forlino, M., Rodríguez, A., Ré, M., Santos, N. C. G., Dimov, L., Apoloni, S. B., Remón, J., Ávila, P. J., et al. (2022) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v56i2sup.539 · Cited by 6
Continuous Glucose Monitoring in Individuals With Type 2 Diabetes: A Quality Improvement Program
Kinson, L., & Inman, K. (2024) · Clinical Diabetes · doi:10.2337/cd24-0006 · Cited by 5
Hermanns, N., Ehrmann, D., & Kulzer, B. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30146-9 · Cited by 2
Self-citationDeak, A. T., Belić, K., Meißl, A.-M., Artinger, K., Eller, K., Rechberger, B., Niedrist, T., Graier, W. F., Malli, R., Bischof, H., et al. (2022) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfac195 · Cited by 2
Uduku, C. N., Pendolino, V., Godsland, I. F., Oliver, N. S., Reddy, M., & Fothergill, R. T. (2021) · Diabetic Medicine · doi:10.1111/dme.14654 · Cited by 3
Glycemic control in patients with diabetes mellitus on hemodialysis
Геннадьевна, Л. К., Severina, A. S., Martynov, S. A., Шамхалова, М. Ш., & Shestakova, M. V. (2019) · Terapevticheskii arkhiv · doi:10.26442/00403660.2019.10.000352 · Cited by 2
“Так, по данным исследования HypoDe, в группе пациентов с СД1, использующих СМГ, риск гипогликемий снижался на 72% по сравнению с контрольной группой [35].”
Lazar, D., Tao, M., Matievich, W., Kastanos, K., & Dunn, T. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241260038 · Cited by 2
Exogenous vs Endogenous Insulin Delivery: 2025
Patel, A., Todd, R., Owen‐Simon, N. L., & McCune, K. R. (2025) · Current Transplantation Reports · doi:10.1007/s40472-025-00468-6 · Cited by 1
Chu, L., & Abitbol, A. (2025) · Diabetic Medicine · doi:10.1111/dme.70119 · Cited by 1
Muller, N., Kellner, C., Schmidt, S., Kuniß, N., Wolf, G., & Kloos, C. (2025) · Diabetic Medicine · doi:10.1111/dme.70121 · Cited by 1
“CGM can reduce the fear of hypoglycaemia and improve quality of life in participants with type 1 diabetes without and with IAH 24,25 whereas in participants with type 2 diabetes the evidence is not clear, probably due to the lower frequency of hypoglycaemia in these participants.”
Sakane, N., Kato, K., Hata, S., Nishimura, E., Araki, R., Kouyama, K., Hatao, M., Matoba, Y., Matsushita, Y., Domichi, M., et al. (2025) · Diabetology International · doi:10.1007/s13340-025-00846-6 · Cited by 1
Metadata
- Authors
- Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N.
- Affiliations
- Universität Ulm (DE)
- Forschungsinstitut der Diabetes Akademie Mergentheim (DE)
- Dexcom (United States) (US)
- Corresponding author
- Hermanns, Norbert
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 391
- Issue
- 10128
- Pages
- 1367-1377
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2786804638
- Cited by
- 522
- References
- 30
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 75 · 2023: 65 · 2022: 73 · 2021: 73 · 2020: 62 · 2019: 63 · 2018: 28
- FWCI
- 44.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- real-time continuous glucose monitoring, type 1 diabetes, hypoglycemia, severe hypoglycemia, multiple daily insulin injections, hypoglycemia prevention, self-monitoring of blood glucose, adults with diabetes
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Follow-Up Studies, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.